Plastic substrates based separation channels in electromigration techniques.

Abstract

Three types of plastic materials (polyester, polyurethane and polymethylmethacrylate) were tested as materials for manufacturing separation columns (polyester and polyurethane capillaries were used) or separation channels (polymethylmethacrylate) in the chip format. A set of 11 fluorescein isothiocyanate amino acid derivatives was used as the test mixture. Using alpha-cyclodextrin additive to the background electrolyte in the case of the chip separation was also tested. The main problem with all plastic separation media was the selectivity of the separation. The best results, practically identical with bare fused silica capillary, were obtained with the polymethylmethacrylate chip, provided that alpha-cyclodextrin in a concentration 40 mmol/l was added to the background electrolyte. An important observation was that in SDS containing background electrolyte all the plastic materials used exhibited a distinct electroosmotic flow, which was ascribe to the sorption of the negatively charged constituents of the background electrolyte to the capillary wall. Regarding the order in which the individual components of the test mixture were brought to the detector only a single change was observed. Histidine migrated in the polystyrene and polymethylmethacrylate separation channels more slowly than in the bare silica or polyurethane based capillaries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jana Charvátová, Zdenek Deyl, Miroslav Klevar, Ivan Miksík, Adam Eckhardt. 2004-02-05. Plastic substrates based separation channels in electromigration techniques.. https://doi.org/10.1016/j.jchromb.2003.10.073

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

A new mass spectrometry electrospray tip obtained via precise mechanical micromachining.

A new electrospray tip incorporating a beveled edge has been designed for use in plastic electrophoresis chip/electrospray mass spectrometry. Theoretical hydrodynamic analysis has been conducted to model the analytical sensitivity of the spray tip shape. A larger sample wall, that provides increased hydraulic pressure, is recommended in order to preserve the fluid stability at the tip outlet. A polymer with better hydrophobic characteristics than glass was used for the spray tip in order to restrict moisture accumulation at the spray tip outlet. Experimental results demonstrate that the analytical sensitivity of the proposed scheme is better than that obtained using the flat-head tip. Although a tapered capillary tip is commonly used in electrophoresis chip/electrospray mass spectrometry, the proposed tip offers a similar sensitivity while being more rugged and durable than the conventional tapered capillary tip. The cost of our design is also much lower than conventional spray tips.

Electrophoresis, Capillary↗

Capillary electrophoresis apparatus equipped with a bioluminescence detector using a batch- or flow-type detection cell.

We developed a capillary electrophoresis (CE) apparatus equipped with a batch- or flow-type bioluminescence (BL) detection cell. Firefly luciferin-luciferase BL reaction was used to analyze samples of nucleotides, such as ATP, dATP, ADP, GTP, UTP, CTP, ITP, and TTP. In the CE apparatus with the batch-type cell, ATP was detected at concentrations of 5-100 microM, while the other nucleotides were not detected at concentrations less than 500 microM. The electropherogram of ATP included two BL peaks; the latter peak showed peculiar broadening, which continued up to ca. 2.5 h. In the CE apparatus with the flow-type cell, ATP, dATP, and ADP were detected with single peaks with detection limits of 1, 75, and 100 microM, respectively. The other nucleotides, GTP, UTP, CTP, ITP, and TTP, were not detected at concentrations less than 0.5 mM. A mixture of 10 microM ATP and 100 microM dATP was examined using the CE apparatus with the flow-type BL detection cell. ATP and dATP were separated using running buffer at pH 10 containing 1 mM phenylboronic acid. The interaction between ATP and phenylboronic acid delayed the migration time of ATP.

Electrophoresis, Capillary↗