Search PubMed⌕ Search

PubMed · 14692221

Predictable esthetic indirect restorations.

Abstract

Patients are increasingly requesting esthetic tooth-colored restorations. Direct composite restorations have limitations based on the size of the restoration, the ability of the patient to tolerate procedures, and the ability of the dentist to provide functional restorations. The indirect composite restoration is ideal for replacing multiple failing restorations in teeth with existing restorations that are too large to be restored with direct composite restorations, yet too small to warrant the preparation for complete crowns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel H Ward. 2003. Predictable esthetic indirect restorations.. https://pubmed.ncbi.nlm.nih.gov/14692221/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radioactively contaminated electric arc furnace dust as an addition to the immobilization mortar in low- and medium-activity repositories.

Electric arc furnace dust (EAFD), generated by the steel-making industry, is in itself an intrinsic hazardous waste; however, the case may also be that scrap used in the process is accidentally contaminated by radioactive elements such as cesium. In this case the resulting EAFD is to be handled as radioactive waste, being duly confined in low- and medium-activity repositories (LMAR). What this paper studies is the reliability of using this radioactive EAFD as an addition in the immobilization mortar of the containers of the LMAR, that is, from the point of view of the durability. Different mixes of mortar containing different percentages of EAFD have been subjected to flexural and compressive strength, initial and final setting time, XRD study, total porosity and pore size distribution, determination of the chloride diffusion coefficient, dimensional stability tests, hydration heat, workability of the fresh mix, and leaching behavior. What is deduced from the results is that for the conditions used in this research, (cement + sand) can be replaced by EAFD upto a ratio [EAFD/(cement + EAFD)] of 46% in the immobilization mortar of LMAR, apparently without any loss in the long-term durability properties of the mortar.

Cementation↗

Estimation of the minimum number of test specimens for fatigue testing of acrylic bone cement.

In the literature on fatigue testing of acrylic bone cements, data sets of various sizes have been used in different test series for the same cement formulation. There are two important consequences of this situation. First, it means that some test series last much longer than others, with all the implications for the cost of testing. Second, it makes drawing conclusions about the fatigue performance of a cement, based on the results of different literature series, a problematic issue. Clearly then, a recommendation as to what should be the minimum number of test specimens to use that would allow for confidence in the results of the statistical treatment of the test results (Gmin) would be desirable. In the present work, a method that could be used to culminate in such a recommendation is described. This method involves (i) obtaining experimental fatigue test results and (ii) analyzing those results using the Weibull probability distribution function and other statistical methods. This methodology is illustrated using fatigue life results obtained from uniaxial tension-compression fatigue tests on specimens fabricated from the polymerizing dough of one commercially available acrylic bone cement. For a tolerable error of 5%, we estimated Gmin to be either 7 (if the fatigue life results are treated using the two-parameter Weibull distribution function) or 11 (if the fatigue life results are treated using the three-parameter Weibull distribution function). To be on the conservative side, we therefore recommend that Gmin be 11. Three key limitations of the methodology presented here are discussed.

Cementation↗

Effects of resin composite composition and irradiation distance on the performance of curing lights.

This study determined the effect of using five resin composites and two irradiation distances to test the performance of dental curing lights. Three types of curing lights with similar spectral distributions, but each delivering a different power density, were used for irradiation times ranging from 3 to 60 s. Power densities were measured at 2 and 9 mm from the tip of the light guide. Five composites 1.6 mm thick and of the same shade were irradiated at 2 and 9 mm from the light guide with energy densities of 1.2-38.0 J/cm(2). The Knoop hardness at the top and bottom of the composite specimens was measured 15 min after irradiation and again after immersion in water at 37 degrees C for 24 h. There was a linear relationship between the hardness and the logarithm of the energy density received by the composite (r2 > 0.81). The analysis of variance showed that the composite, the side tested, the distance from the light guide, and the curing light/irradiation time combination all had a significant effect on the hardness (p < 0.01). Plots of the hardness at the bottom 15 min after irradiation by each light were generated for all the composites. These plots illustrated that the effects of the different curing light/irradiation time combinations on hardness were not the same for each composite. The effects of each curing light/time combination on hardness were also different at 2 and 9 mm from the light guide. In conclusion, when comparing the effects of different light sources on resin polymerization, several different composites should be irradiated at clinically relevant distances from the light guide. Using high-powered curing lights for 3 or 5 s did not deliver sufficient energy to cure the 1.6-mm thick specimens of composites used in this study.

Cementation↗