Search PubMed⌕ Search

PubMed · 14659949

Real-time-monitored decrease of trichlorophenol as a dioxin surrogate in flue gas using iron oxide catalyst.

Abstract

The decrease of trichlorophenol by injecting oxidation catalyst into a municipal solid waste incinerator was monitored in real time. Direct sampling atmospheric pressure chemical ionization (APCI)/ion trap mass spectrometry (ITMS) was used for the real-time monitoring. The oxidation catalyst was iron oxide type, which exponentially reduced trichlorophenol emission. CO emission, however, did not show any correlation with the catalyst injection rate. Simultaneous analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs) suggested that real-time monitoring of trichlorophenol as a surrogate of PCDDs/PCDFs, has a potential to timely control the optimum injection rate of PCDD/PCDF suppression catalyst continuously and economically.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Masuyoshi Yamada, Izumi Waki, Minoru Sakairi, Masami Sakamoto, Tomoyuki Imai. 2004. Real-time-monitored decrease of trichlorophenol as a dioxin surrogate in flue gas using iron oxide catalyst.. https://doi.org/10.1016/j.chemosphere.2003.10.031

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stable chloroform emissions in southeastern China: insights from recent observations.

Chloroform (CHCl3) is a short-lived ozone-depleting substance not currently regulated under the Montreal Protocol. Due to the unique meteorological conditions in East Asia, CHCl3 emitted in this region has a greater potential to reach the stratosphere and contribute to ozone depletion. As an essential component of national CHCl3 emissions, southeastern China has attracted increasing attention. However, long-term observational data in this region remain relatively scarce, with no updates since 2020. In this study, we continuously measured atmospheric CHCl3 concentrations at a remote monitoring station in southeastern China from 1 June 2023 to 31 May 2025. Frequent concentration enhancements were observed during the monitoring period, with mixing ratios ranging from 9.3 to 134.1 ppt and an average value of 36.8 ± 19.7 ppt. Back-trajectory analysis indicated that air masses associated with elevated CHCl3 levels primarily originated from coastal industrial provinces in eastern China. Using the Potential Source Contribution Function and Concentration Weighted Trajectory methods, we identified the Yangtze River Delta (Jiangsu, Anhui, and Zhejiang Provinces) and Jiangxi Province as dominant source regions. Emissions of CHCl3 in southeastern China were estimated using the Tracer Ratio Method to be approximately 30.1 ± 5.3 Gg/yr from 2023-06-01 to 2025-05-31, indicating overall stability relative to earlier estimates and no apparent upward trend. These findings provide updated insights into the current status of CHCl3 emissions in southeastern China and highlight the need for continued monitoring and emission assessment of CHCl3 in East Asia, given its unregulated status and implications for ozone layer recovery.

Air Pollutants↗

Evaluation and quality control of personal nephelometers in indoor, outdoor and personal environments.

Personal nephelometers provide useful real-time measurements of airborne particulate matter (PM). Recent studies have applied this tool to assess personal exposures and related health effects. However, a thorough quality control (QC) procedure for data collected from such a device in a large-scale exposure assessment study is lacking. We have evaluated the performance of a personal nephelometer (personal DataRAM or pDR) in the field. We present here a series of post hoc QC procedures for improving the quality of the pDR data. The correlations and the ratios between the pDRs and the collocated gravimetric measurements were used as indices of the pDR data quality. The pDR was operated in four modes: passive (no pump), active (with personal sampling pumps), active with a heated inlet, and a humidistat. The pDRs were worn by 21 asthmatic children, placed at their residences indoors and outdoors, as well as at a central site. All fixed-site pDRs were collocated with Harvard Impactors for PM2.5 (HI2.5). By examining the differences between the time-weighted average concentrations calculated from the real-time pDRs' readings and recorded internally by the pDRs, we identified 9.1% of the pDRs' measurements suffered from negative drifts. By comparing the pDRs' daily base level with the HI2.5 measurements, we identified 5.7% of the pDRs' measurements suffered from positive drifts. High relative humidity (RH) affected outdoor pDR measurements, even when a heater was used. Results from a series of chamber experiments suggest that the heated air stream cooled significantly after leaving the heater and entering the pDR light-scattering chamber. An RH correction equation was applied to the pDR measurements to remove the RH effect. The final R2 values between the fixed-site pDRs and the collocated HI2.5 measurements ranged between 0.53 and 0.72. We concluded that with a carefully developed QC procedure, personal nephelometers can provide high-quality data for assessing PM exposures on subjects and at fixed locations. We also recommend that outdoor pDRs be operated in the active mode without a heater and that the RH effect be corrected with an RH correction equation.

Air Pollutants↗

Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: analyses of RIOPA data.

The Relationship of Indoor, Outdoor and Personal Air (RIOPA) study was designed to investigate residential indoor, outdoor and personal exposures to several classes of air pollutants, including volatile organic compounds, carbonyls and fine particles (PM2.5). Samples were collected from summer, 1999 to spring, 2001 in Houston (TX), Los Angeles (CA) and Elizabeth (NJ). Indoor, outdoor and personal PM2.5 samples were collected at 212 nonsmoking residences, 162 of which were sampled twice. Some homes were chosen due to close proximity to ambient sources of one or more target analytes, while others were farther from sources. Median indoor, outdoor and personal PM2.5 mass concentrations for these three sites were 14.4, 15.5 and 31.4 microg/m3, respectively. The contributions of ambient (outdoor) and nonambient sources to indoor and personal concentrations were quantified using a single compartment box model with measured air exchange rate and a random component superposition (RCS) statistical model. The median contribution of ambient sources to indoor PM2.5 concentrations using the mass balance approach was estimated to be 56% for all study homes (63%, 52% and 33% for California, New Jersey and Texas study homes, respectively). Reasonable variations in model assumptions alter median ambient contributions by less than 20%. The mean of the distribution of ambient contributions across study homes agreed well for the mass balance and RCS models, but the distribution was somewhat broader when calculated using the mass balance model with measured air exchange rates.

Air Pollutants↗