Search PubMed⌕ Search

PubMed · 14523969

High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes.

Abstract

In this work we report on the development of a novel technique for high-resolution diffusion-weighted (DW) MRI based upon 3D steady-state free precession (3D-SSFP). First the 3D-SSFP acquisition was segmented (each segment consisting of a series of RF pulses and gradient-recalled echoes), and then DW-driven equilibrium (DE) was inserted between each segment. The in-plane imaging matrix was typically 256 x 192 or 256 x 160, which resulted in high-resolution DW images. The DW-DE segmented SSFP signal was contaminated by the non-DW magnetization, which recovered and contributed signal during the readout train (T(1) contamination). Center-out slice encoding was used to place the greatest diffusion weighting at the center of k-space. A numerical simulation and supporting experiments were performed to evaluate the relationship of the transverse magnetization to imaging parameters, such as the b-value, echo-train length (ETL), echo-train (group) repetition time (TR(g)), and RF excitation TR (Delta t). Both the numerical simulation and the experiments suggested that the effect of T(1) contamination would be reduced with a longer TR(g), smaller b-value, shorter ETL, and center-out slice phase encoding. Phase errors caused by microscopic motions during the diffusion gradients were converted into amplitude errors by the tip-up pulse at the end of the diffusion-weighting segment. As a result, small bulk motions, such as CSF pulsation, did not cause motion-related ghosting artifacts, which would be typical in images from other multishot DWI techniques. This technique can be used for high-resolution DWI of nonbrain anatomies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eun-Kee Jeong, Seong-Eun Kim, Dennis L Parker. 2003. High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes.. https://doi.org/10.1002/mrm.10593

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗