Search PubMed⌕ Search

Biomedical subjects

Eun-Kee Jeong

Publications and source records attributed to Eun-Kee Jeong.

17 recordsLinked to original sources

Hepatic MRI using the double-echo chemical shift phase-selective gradient-echo technique.

OBJECTIVE: The objective of our study was to describe the merits and drawbacks of the double-echo chemical shift phase-selective gradient-echo technique for hepatic MRI. CONCLUSION: With complementary information from two different dynamic imaging sets in conjunction with errorless subtraction between in- and out-of-phase images, the double-echo chemical shift phase-selective gradient-echo technique provides useful information regarding unpredictable variations in intra- or extralesional lipid content, allowing detailed assessment of focal lesions during hepatic MRI.

Adipose Tissue↗

Diffusion tensor imaging of the corpus callosum in Autism.

The corpus callosum is the largest commissural white matter pathway that connects the hemispheres of the human brain. In this study, diffusion tensor imaging (DTI) was performed on subject groups with high-functioning autism and controls matched for age, handedness, IQ, and head size. DTI and volumetric measurements of the total corpus callosum and subregions (genu, body and splenium) were made and compared between groups. The results showed that there were significant differences in volume, fractional anisotropy, mean diffusivity, and radial diffusivity between groups. These group differences appeared to be driven by a subgroup of the autism group that had small corpus callosum volumes, high mean diffusivity, low anisotropy, and increased radial diffusivity. This subgroup had significantly lower performance IQ measures than either the other individuals with autism or the control subjects. Measurements of radial diffusivity also appeared to be correlated with processing speed measured during the performance IQ tests. The subgroup of autism subjects with high mean diffusivity and low fractional anisotropy appeared to cluster with the highest radial diffusivities and slowest processing speeds. These results suggest that the microstructure of the corpus callosum is affected in autism, which may be related to nonverbal cognitive performance.

Adolescent↗

Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

PURPOSE: The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. METHODS: Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. RESULTS: The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. CONCLUSION: These novel GCAC are promising contrast agents for cardiovascular and tumor MRI, which are later cleaved into low molecular weight Gd(III) chelates and rapidly cleared from the body.

Animals↗

k-space inherited parallel acquisition (KIPA): application on dynamic magnetic resonance imaging thermometry.

In this study, a novel method for dynamic parallel image acquisition and reconstruction is presented. In this method, called k-space inherited parallel acquisition (KIPA), localized reconstruction coefficients are used to achieve higher reduction factors, and lower noise and artifact levels compared to that of generalized autocalibrating partially parallel acquisition (GRAPPA) reconstruction. In KIPA, the full k-space for the first frame and the partial k-space for later frames are required to reconstruct a whole series of images. Reconstruction coefficients calculated for different segments of k-space from the first frame data set are used to estimate missing k-space lines in corresponding k-space segments of other frames. The local determination of KIPA reconstruction coefficients is essential to adjusting them according to the local signal-to-noise ratio characteristics of k-space data. The proposed algorithm is applicable to dynamic imaging with arbitrary k-space sampling trajectories. Simulations of magnetic resonance thermometry using the KIPA method with a reduction factor of 6 and using dynamic imaging studies of human subjects with reduction factors of 4 and 6 have been performed to prove the feasibility of our method and to show apparent improvement in image quality in comparison with GRAPPA for dynamic imaging.

Algorithms↗

Contrast enhanced MRI-guided photodynamic therapy for site-specific cancer treatment.

Photodynamic therapy (PDT) is a minimally invasive and effective approach for cancer treatment. It is potentially useful for treating tumors that are not accessible to surgery, radiation, or destructive ablations, and are resistant to chemotherapy. Efficacious treatment of interstitial tumors with PDT requires efficient delivery of photosensitizers and accurate location of tumor tissues for effective light irradiations. In this study we performed contrast-enhanced (CE) MRI-guided PDT with a bifunctional polymer conjugate containing both a magnetic resonance imaging (MRI) contrast agent and a photosensitizer, poly(L-glutamic acid) (PGA)-(Gd-DO3A)-mesochlorin e(6) (Mce(6)). The efficacy of the bifunctional conjugate in cancer CE-MRI and cancer treatment was evaluated in athymic nude mice bearing MDA-MB-231 human breast carcinoma xenografts, with PGA-(Gd-DO3A) used as a control. The polymer conjugates preferentially accumulated in the solid tumor due to the hyperpermeability of the tumor vasculature, resulting in significant tumor enhancement for accurate tumor detection and localization by MRI. Significant therapeutic response was observed for PDT with the bifunctional conjugate as compared to the control. CE-MRI-guided PDT with the bifunctional conjugate is effective for tumor detection and minimally invasive cancer treatment.

Analysis of Variance↗

High-resolution DTI of a localized volume using 3D single-shot diffusion-weighted STimulated echo-planar imaging (3D ss-DWSTEPI).

Diffusion tensor MRI (DTI) using conventional single-shot (SS) 2D diffusion-weighted (DW)-EPI is subject to severe susceptibility artifacts. Multishot DW imaging (DWI) techniques can reduce these distortions, but they generally suffer from artifacts caused by motion-induced phase errors. Parallel imaging can also reduce the distortions if the sensitivity profiles of the receiver coils allow a sufficiently high reduction factor for the desired field of view (FOV). A novel 3D DTI technique, termed 3D single-shot STimulated EPI (3D ss-STEPI), was developed to acquire high-resolution DW images of a localized region. The new technique completes k-space acquisition of a limited 3D volume after a single diffusion preparation. Because the DW magnetization is stored in the longitudinal direction until readout, it undergoes T(1) rather than T(2) decay. Inner volume imaging (IVI) is used to limit the imaging volume. This reduces the time required for EPI readout of each complete k(x)-k(y) plane, and hence reduces T(2)(*) decay during the readout and T(1) decay between the readout of each k(z). 3D ss-STEPI images appear to be free of severe susceptibility and motion artifacts. 3D ss-STEPI allows high-resolution DTI of limited volumes of interest, such as localized brain regions, cervical spinal cord, optic nerve, and other extracranial organs.

Algorithms↗

Pharmacokinetics, biodistribution and contrast enhanced MR blood pool imaging of Gd-DTPA cystine copolymers and Gd-DTPA cystine diethyl ester copolymers in a rat model.

PURPOSE: To investigate plasma pharmacokinetics and biodistribution of biodegradable polydisulfide Gd(III) complexes, Gd-DTPA cystine copolymers (GDCP) and Gd-DTPA cystine diethyl ester copolymers (GDCEP) and their efficacy as blood pool MRI contrast agents in comparison with a nondegradable macromolecular agent, Gd-DTPA 1,6-hexanediamine copolymers (GDHC). METHODS: The pharmacokinetics and biodistribution of GDCP and GDCEP with molecular weight of 35 KDa were investigated in Sprague-Dawley rats after intravenous administration at a dose of 0.1 mmol Gd/kg. GDHC with the same molecular weight was used as a control. The Gd content in the plasma and various tissues and organs were determined by the ICP-OES. Plasma pharmacokinetic parameters were calculated by using a two-compartment model. The contrast enhanced blood pool MR imaging of the agents was evaluated in Sprague-Dawley rats on a Siemens Trio 3T MR scanner. RESULTS: The biodegradable macromolecular agents, GDCP and GDCEP, had faster blood pool clearance than the nondegradable GDHC. The long-term Gd(III) tissue retention of the biodegradable polydisulfide agents was substantially lower than the nondegradable macromolecular agent. Both GDCP and GDCEP resulted in significant blood pool enhancement for the first 2 min post-injection and more rapid disappearance of the enhancement over time than GDHC. The negatively charged GDCP had prolonged enhancement duration as compared to GDCEP. The structure and biodegradability of the macromolecular contrast agents significantly affected their pharmacokinetics and blood pool contrast enhancement. CONCLUSION: Both GDCP and GDCEP provided effective contrast enhancement for MR imaging of the blood pool. The accumulation of toxic Gd(III) ions in the body was greatly reduced with GDCP and GDCEP as compared to the nondegradable control.

Animals↗

High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI).

Diffusion tensor MRI (DTI), using single-shot 2D diffusion weighted-EPI (2D ss-DWEPI), is limited to intracranial (i.c.) applications far from the sinuses and bony structures, due to the severe geometric distortions caused by significant magnetic field inhomogeneities at or near the tissue-air or tissue-bone interfaces. Reducing these distortions in single-shot EPI by shortening the readout period generally requires a reduced field of view (and the potential of wraparound artifact) in the phase-encoding direction and/or reduced spatial resolution. To resolve the problem, a novel 2D reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI) pulse sequence applicable for high resolution diffusion-weighted MRI of local anatomic regions, such as brainstem, cervical spinal cord, and optic nerve, has been developed. In the proposed technique, time-efficient interleaved acquisition of multiple slices with a limited FOV was achieved by applying an even number of refocusing 180 degrees pulses with the slice-selection gradient applied in the phase-encoding direction. The two refocusing pulses used for each slice acquisition were separated by a short time interval (typically less than 45 ms) required for the 2D EPI echotrain acquisition. The new technique can be useful for high resolution DTI of various anatomies, such as localized brain structures, cervical spinal cord, optic nerve, heart, or other extra-cerebral organ, where conventional 2D ss-DWEPI is limited in usage due to the severity of image distortions.

Algorithms↗

Triple contrast technique for black blood imaging with double inversion preparation.

This work reports on the development of a pulse sequence to simultaneously acquire proton density, T(1), and T(2) weighted images in a single magnetization prepared fast spin echo acquisition. The technique is based upon the application of a magnetization preparation consisting of a global inversion followed by slice-selective 180 degrees and 90 degrees pulses to prepare the signal of specific slices. Slices are acquired in an interleaved manner with time delays appropriate for the desired image contrasts. Data acquisition is repeated for all combinations of slice interleaving covering the region of interest until images from all slice locations have been acquired with all desired image contrasts. The multiple image contrasts obtained with this technique should be useful in applications where discrimination between different types of tissue components is desired, such as in the analysis of plaque in cervical carotid artery disease.

Arteriosclerosis↗

Assessment of subconjunctival delivery with model ionic permeants and magnetic resonance imaging.

PURPOSE: The objective was to assess the permeation and clearance of model ionic permeants after subconjunctival injection with nuclear magnetic resonance imaging (MRI). METHODS: New Zealand white rabbit was the animal model and manganese ion (Mn2+) and manganese ethylenediaminetetraacetic acid complex (MnEDTA2-) were the model permeants. The current study was divided into three parts: in vitro, postmortem, and in vivo. Transscleral passive permeation experiments were conducted with excised sclera in side-by-side diffusion cells in vitro. Subconjunctival delivery experiments were conducted with rabbits postmortem and in vivo. The distribution and elimination of the probe permeants from the subconjunctival space after subconjunctival injections were determined by MRI. RESULTS: The data of excised sclera in vitro suggest large effective pore size for transscleral transport and negligible pore charge effects upon the permeation of the ionic permeants. The permeability coefficients of Mn2+ and MnEDTA2- across the sclera in vitro were 3.6 x 10(-5) cm/s and 2.4 x 10(-5) cm/s, respectively. Although relatively high sclera permeability was observed in vitro, subconjunctival injections in vivo did not provide significant penetration of Mn2+ and MnEDTA2- into the globe; permeant concentrations in the eye were below the detection limit, which corresponds to less than 0.05% of the concentration of the injection solution (e.g., less than 0.02 mM when 40 mM injection solution was used). The volume of the subconjunctival pocket and the concentration of the permeants in the pocket were observed to decrease with time after the injection, and this could contribute to the lower than expected subconjunctival absorption in vivo. Different from the results in vivo, experiments with rabbits postmortem show significant penetration of Mn2+ and MnEDTA2- into the globe with the permeants primarily delivered into the anterior segment of the eye. This difference suggests blood vasculature clearance as a main barrier for passive transscleral transport. The data also show that the pars plicata/pars plana is the least resistance pathway for passive transscleral drug delivery of the polar permeants, and there are indications of the presence of another barrier, possibly the retinal epithelium and/or Bruch's membrane, at the back of the eye. CONCLUSIONS: Subconjunctival delivery of the ionic permeants in vivo cannot be quantitatively predicted by the in vitro results. MRI is a noninvasive complementary technique to traditional pharmacokinetic methods. It can provide insights into ocular pharmacokinetics without permeant redistribution that can occur in surgical procedure postmortem in traditional pharmacokinetic studies when the blood vasculature barrier is absent.

Animals↗

Magnetic resonance imaging study of current and ion delivery into the eye during transscleral and transcorneal iontophoresis.

PURPOSE: The objectives were to determine by nuclear magnetic resonance imaging (MRI) the target sites of ion delivery in the eye during iontophoresis, compare transscleral and transcorneal ocular iontophoresis, and monitor the distribution of a probe ion in the anterior chamber and vitreous after iontophoretic delivery. METHODS: Thirty-minute 2-mA anodal constant current transscleral and transcorneal iontophoresis (current density, 10 mA/cm(2)) was performed on three New Zealand White rabbits in vivo. Intravitreal injection and passive delivery were the controls. Transscleral and transcorneal iontophoresis experiments were conducted with the electrode device placed in the superior cul-de-sac away from the limbus and on the cornea adjacent to the limbus, respectively. During iontophoresis, the current delivered into the eye was monitored using a probe ion (Mn(2+)) with MRI. The distributions of the ion in the aqueous and vitreous humor after iontophoresis, passive delivery, and intravitreal injection were also determined by MRI. RESULTS: With the short application time, passive diffusion did not deliver a significant amount of the ion into the eye. Whereas transscleral iontophoresis delivered the ion into the vitreous, transcorneal iontophoresis delivered the ion into the anterior chamber. The current pathways during iontophoresis were mainly from the electrode into the eye, perpendicular to the electrode-eye interface beneath the electrode. Electric current along the surface of the globe was relatively minimal. With the present transscleral iontophoresis protocol, the ion penetrated the sclera and traveled as far as 1.5 mm from the electrode-conjunctiva interface into the vitreous. For transcorneal iontophoresis, the ion penetrated the cornea and filled the entire anterior chamber. CONCLUSIONS: MRI can be a useful technique in the study of the penetration of probe compounds in the eye during and after iontophoresis, such as in iontophoresis protocol and device testing. Ocular pharmacokinetic studies using MRI are noninvasive and provide real-time data without perturbation and compound redistribution that can occur during dissection and assay in traditional pharmacokinetic studies. With MRI, it was shown that transscleral iontophoresis, transcorneal iontophoresis, and intravitreal injection deliver ions to different parts of the eye.

Animals↗

The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes.

In this work we report on the development of a novel technique for high-resolution diffusion-weighted (DW) MRI based upon 3D steady-state free precession (3D-SSFP). First the 3D-SSFP acquisition was segmented (each segment consisting of a series of RF pulses and gradient-recalled echoes), and then DW-driven equilibrium (DE) was inserted between each segment. The in-plane imaging matrix was typically 256 x 192 or 256 x 160, which resulted in high-resolution DW images. The DW-DE segmented SSFP signal was contaminated by the non-DW magnetization, which recovered and contributed signal during the readout train (T(1) contamination). Center-out slice encoding was used to place the greatest diffusion weighting at the center of k-space. A numerical simulation and supporting experiments were performed to evaluate the relationship of the transverse magnetization to imaging parameters, such as the b-value, echo-train length (ETL), echo-train (group) repetition time (TR(g)), and RF excitation TR (Delta t). Both the numerical simulation and the experiments suggested that the effect of T(1) contamination would be reduced with a longer TR(g), smaller b-value, shorter ETL, and center-out slice phase encoding. Phase errors caused by microscopic motions during the diffusion gradients were converted into amplitude errors by the tip-up pulse at the end of the diffusion-weighting segment. As a result, small bulk motions, such as CSF pulsation, did not cause motion-related ghosting artifacts, which would be typical in images from other multishot DWI techniques. This technique can be used for high-resolution DWI of nonbrain anatomies.

Artifacts↗

Postoperative evaluation of moyamoya disease with perfusion-weighted MR imaging: initial experience.

BACKGROUND AND PURPOSE: Encephaloduroarteriosynangiosis (EDAS) has become the main treatment for moyamoya disease, a chronically progressive cerebrovascular occlusive disease in children. We aimed to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic changes before and after EDAS. METHODS: Thirteen patients with angiographically confirmed moyamoya disease who underwent EDAS were investigated, and results were compared with those of a control group (n = 5). Perfusion MR imaging was performed before and after EDAS by using a T2*-weighted contrast material-enhanced technique. Relative cerebral blood volume (rCBV) and time to peak enhancement (TTP) maps were calculated. Relative ratios of rCBV and TTP in the middle cerebral artery (MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery (PCA). Changes in hemodynamic parameters between pre- and post-EDAS perfusion maps were investigated. RESULTS: The mean rCBV ratio of MCA to PCA in the patient group was slightly higher than that in the control group, without statistical significance. All 13 patients showed a delayed TTP in the MCA before EDAS compared with the control group (P =.0006), and the TTP after EDAS was significantly reduced (P =.0002). In the basal ganglia, shortening of the TTP was demonstrated before EDAS, but no significant change was observed after EDAS. CONCLUSION: Perfusion-weighted MR imaging can be applied for evaluating postoperative changes in cerebral blood flow in moyamoya disease. Shortening of the TTP in the MCA of the hemisphere operated on is a marker for the development of collateral circulation from the external carotid artery to the internal carotid artery.

Adolescent↗

UNFOLD using a temporal subtraction and spectral energy comparison technique.

In dynamic MRI, several methods have been demonstrated to increase acquisition speed by decreasing the number of sequential phase encodings. The UNFOLD technique interleaves the measurements of k-space, reconstructs aliased images from each k-space interleaf, and applies a temporal low-pass filter to obtain the nonaliased images. However, low-pass filter resolution of the nonaliased images fails if there is overlap between the spatially aliased temporal spectra. In this study a subtraction method was used to remove the static portion of the image. The aliased and nonaliased dynamic portions are then resolved by comparing the temporal energy of bands in the power spectrum. This method was combined with the 3D 2 x 2 UNFOLD (a factor of 2 interleaves in two directions) technique. The combination resulted in a factor of 4 improvement in acquisition speed. Application of this method to a time-resolved, contrast-enhanced flow phantom study is presented.

Algorithms↗

Reduction of flow-related signal loss in flow-compensated 3D TOF MR angiography, using variable echo time (3D TOF-VTE).

High-resolution MRA with phase/frequency flow compensation may require very long echo times (TEs). Variable TE (VTE) was implemented into flow-compensated 3D TOF to minimize the effective TE and reduce the flow-related signal void. The k-space of the 3D TOF was divided into segment groups ranging from two to 32 segments with different TEs. The TEs were minimized and the flow-compensation gradient lobes were calculated to null the total first moment at the peak of the echo for each segment. Possible artifacts and off-resonance effects were evaluated, with respect to the number of TE segments, using the point spread function (PSF) and corresponding experiments. The optimal number of TE segments for the least artifact was determined to be one-half of the number of slices. Two types of artifacts caused by VTE were predicted and subsequently observed. The developed pulse sequence 3D TOF-VTE was tested on clinical MRI systems, by performing scans of the cervical carotid artery and intracranial carotid artery at the carotid siphon. The signal distribution near the bifurcation and the siphon was much more uniform with VTE, and the flow-related signal loss was greatly reduced. The resultant MR angiograms provided improved vessel detail. The results show that VTE improved the quality of flow-compensated 3D TOF MRA.

Artifacts↗

Noninvasive visualization of in vivo drug delivery of poly(L-glutamic acid) using contrast-enhanced MRI.

Biomedical imaging is valuable for noninvasive investigation of in vivo drug delivery with polymer conjugates. It can provide real-time information on pharmacokinetics, biodistribution, and drug delivery efficiency of the conjugates. Noninvasive visualization of in vivo drug delivery of polymer conjugates with contrast-enhanced magnetic resonance imaging (MRI) was studied with paramagnetically labeled poly(L-glutamic acid) in an animal tumor model. Poly(L-glutamic acid) is a biocompatible and biodegradable drug carrier for diagnostics and therapeutics. Poly(L-glutamic acid)-1,6-hexanediamine--(Gd-DO3A) conjugates with molecular weights of 87, 50, and 28 kDa and narrow molecular weight distributions were prepared and studied in mice bearing MDA-MB-231 human breast cancer xenografts. Contrast-enhanced MRI resulted in real-time and three-dimensional visualization of blood circulation, pharmacokinetics, biodistribution, and tumor accumulation of the conjugates, and the size effect on these pharmaceutics properties. The conjugate of 28 kDa rapidly cleared from the circulation and had a relatively lower tumor accumulation. The conjugates with higher molecular weights exhibited a more prolonged blood circulation and higher tumor accumulation. The difference between the conjugates of 87 and 50 kDa was not significant. Contrast-enhanced MRI is effective for noninvasive real-time visualization of in vivo drug delivery of paramagnetically labeled polymer conjugates.

Animals↗