Search PubMed⌕ Search

PubMed · 14089502

[THE ISOTOPE NEPHROGRAM].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H W ROTH, K AFSARY, P WENGER. 1963. [THE ISOTOPE NEPHROGRAM].. https://pubmed.ncbi.nlm.nih.gov/14089502/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Type, severity, frequency and management of adverse reactions associated with ultrasound contrast agents: a systematic review and meta-analysis.

OBJECTIVES: This systematic review and meta-analysis are aimed at evaluating the incidence of adverse drug reactions (ADRs) following administration of clinically approved ultrasound contrast agents (UCAs) in adults and children, to assess risks in patients with cardiovascular disease and in pregnancy, and to evaluate the effectiveness of emergency management of severe ADRs. MATERIALS AND METHODS: A PRISMA 2020 systematic review was conducted searching PubMed, Scopus, and Embase. Two reviewers independently screened, extracted data, and assessed quality. Incidence estimates were pooled when feasible, stratified by age group, contrast agent, and administration route. RESULTS: Seventy-four studies encompassing >&#x2009;1 million adults and >&#x2009;36,000 children were included, contributing multiple analytic cohorts to the quantitative synthesis. Severe acute ADRs were extremely rare (6 and 16 cases per 100,000 in adults and children, respectively) and absent following endocavitary administration in children. Non-severe acute ADRs occurred in 11 and 8 cases per 10,000 adults and children, respectively. Delayed reactions were very rare (<&#x2009;1 case per million in adults). No significant safety differences emerged between UCA products. The incidence of ADRs in patients with cardiovascular disease was analogous to the general population. No ADRs were reported in pregnant women. Standard emergency management was effective in almost all serious cases, though rare fatalities occurred. CONCLUSION: UCAs show an excellent safety profile in adults and children, with very rare severe ADRs and few non-severe, typically self-limiting reactions. Strict adherence to recommended emergency management protocols mitigates the remaining risks, supporting safe use across a broad range of clinical indications. PROSPERO REGISTRATION: CRD42023432668. KEY POINTS: Question What is the incidence, type, and severity of acute and delayed ADRs associated with clinically approved UCAs across different patient populations? Findings Severe acute adverse reactions are very rare, and non-severe reactions are rare and self-limiting, with no significant safety differences between adults, children, or patients with cardiovascular disease. Clinical relevant UCAs show an excellent safety profile across populations. These findings support their safe clinical use as reliable alternatives to iodine-based and gadolinium-based contrast agents in routine diagnostic imaging.

Contrast Media↗

Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT.

The aim of this study was to determine if a saline solution flush following low dose contrast material bolus improves parenchymal and vascular enhancement during abdominal multiple detector-row computed tomography (MDCT). Forty-one patients (24 men and 17 women; mean age 49 years, age range 27-86 years) underwent abdominal MDCT (collimation 4x5 mm, 15-mm table increment, reconstruction interval 5 mm, gantry rotation period 0.8 s) with a single- as well as with a double syringe power injector. Indication for examination were benign and malignant tumors and inflammatory diseases. Patients received 100 ml nonionic contrast material (300 mgI/ml) alone or pushed with 20 ml saline solution. Mean enhancement values for both protocols were measured in the liver, the spleen, the pancreas, the renal cortex, the portal vein, the inferior vena cava and the abdominal aorta. Double syringe power-injector protocol led to significantly higher parenchymal and vascular enhancement than single syringe power-injector protocol (p<0.05). The improvement in mean enhancement of the liver was 9 +/- 9 HU, of the spleen 8 +/- 10 HU, of the pancreas 7 +/- 9 HU, and of the renal cortex 8 +/- 20 HU. The improvement in mean enhancement of the portal vein was 10 +/- 17 HU of the inferior vena cava 8 +/- 13 HU and of the abdominal aorta 10 +/- 17 HU. The use of a double syringe power injector with saline flush following contrast material bolus significantly improves parenchymal and vascular enhancement during contrast-enhanced abdominal MDCT with low iodine doses.

Contrast Media↗