Search PubMed⌕ Search

PubMed · 14088008

A PRACTICAL WATER PHANTOM.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N T WINKLER. 1963. A PRACTICAL WATER PHANTOM.. https://pubmed.ncbi.nlm.nih.gov/14088008/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Method of estimating 10 MV X-ray irregular field dose using the collimator scatter factor (Sc) and phantom scatter factor (Sp)].

It has been found that in general 10 MV X-ray dose calculation can be made accurately for multi-leaf collimator irregular fields by using the total scatter factor (S(cp)), collimator scatter factor (S(c)), and phantom scatter factor (S(p)) proposed by Khan et al. With respect to the collimator scatter factor (S(c)), we used the field-mapping method of Kim et al. to obtain equivalent square fields of irregular fields (the collimator reverse effect can be accurately dissolved using the field-mapping method). Even for extremely small multi-leaf fields compared with the main collimator opening, X-ray output calculations could be made accurately by introducing the small segment correction (SSC) factor. With respect to the phantom scatter factor (S(p)), highly accurate calculations could be made for irregular field irradiation by applying an F(MLC) (MLC radiation leakage) factor to the equivalent square field (in cases in which the ratio of the multi-leaf equivalent square field side to the main collimator equivalent square field side is less than 0.6). However, it has been found that highly accurate dose calculations can, in general, be performed when the main collimator is limited just at the opening determined by the multi-leaf collimator field.

Phantoms, Imaging↗

Megavoltage cone-beam computed tomography using a high-efficiency image receptor.

PURPOSE: To develop an image receptor capable of forming high-quality megavoltage CT images using modest radiation doses. METHODS AND MATERIALS: A flat-panel imaging system consisting of a conventional flat-panel sensor attached to a thick CsI scintillator has been fabricated. The scintillator consists of individual CsI crystals 8 mm thick by 0.38 mm x 0.38-mm pitch. Five sides of each crystal are coated with a reflecting powder/epoxy mixture, and the sixth side is in contact with the flat-panel sensor. A timing interface coordinates acquisition by the imaging system and pulsing of the linear accelerator. With this interface, as little as one accelerator pulse (0.023 cGy at the isocenter) can be used to form projection images. Different CT phantoms irradiated by a 6-MV X-ray beam have been imaged to evaluate the performance of the imaging system. The phantoms have been mounted on a rotating stage and rotated while 360 projection images are acquired in 48 s. These projections have been reconstructed using the Feldkamp cone-beam CT reconstruction algorithm. RESULTS AND DISCUSSION: Using an irradiation of 16 cGy (360 projections x 0.046 cGy/projection), the contrast resolution is approximately 1% for large objects. High-contrast structures as small as 1.2 mm are clearly visible. The reconstructed CT values are linear (R(2) = 0.98) for electron densities between 0.001 and 2.16 g/cm(3), and the reconstruction time for a 512 x 512 x 512 data set is 6 min. Images of an anthropomorphic phantom show that soft-tissue structures such as the heart, lung, kidneys, and liver are visible in the reconstructed images (16 cGy, 5-mm-thick slices). CONCLUSIONS: The acquisition of megavoltage CT images with soft-tissue contrast is possible with irradiations as small as 16 cGy.

Phantoms, Imaging↗

Determination of field size limitations in stereotactic and intensity modulated radiotherapy.

For dose measurement in small photon fields, different detectors are currently in use: TLD, semiconductor, diamond-detector, film, etc. But for absolute dosimetry, ionization chambers show the most advantages. To meet the basic dosimetrical requirements for lateral electron equilibrium the field size F must not remain under specified values: i.e. 5.2 x 5.2 cm2 for 15 MeV X-bremsstrahlung. As well as increasing the focus-chamber-distance, changing the physical density of the build-up material in the close vicinity of the chamber will be helpful to determine the output factor OF for smaller fields. By means of a correction factor, k(mat), this is taken into account. For a 6 MeV X and a 15 MeV X-bremsstrahlung of linear accelerators the lower limit of the field size F is determined: F > or = 0.8 cm. This value is mainly dependent on the diameter of the focal-spot (phi = 3 mm) of the treatment unit including design characteristics of the treatment head. Beside the dosimetrical aspects, some geometrical parameters have to be considered, when accuracy of dose application should remain on the same level as in medium and large field treatment (4 cm < or = F < or = F(max)). To keep dose-volume errors as low as +/- 10 % (diameter of PTV: 20 mm), the mean total error delta of CT-scanning (delta(p)), planning (delta(pl)), patient positioning (delta(x)), and treatment unit instabilities (delta(m)) should not exceed +/- 0.8 mm.

Phantoms, Imaging↗