Search PubMed⌕ Search

PubMed · 13380869

[Aortic arch abnormalities].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A SANDERUD. 1956-11-15. [Aortic arch abnormalities].. https://pubmed.ncbi.nlm.nih.gov/13380869/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.

OBJECTIVE: To compare measurements of cardiac output using a new pulmonary artery catheter with those obtained using two "gold standard" methods: the periaortic transit time ultrasonic flow probe and the conventional pulmonary artery thermodilution. DESIGN: Prospective clinical trial. SETTING: Cardiac surgery operating room and surgical ICU in a university hospital. MATERIAL AND METHODS: In the operating room, a new pulmonary artery catheter (truCCOMS system) was inserted in eight patients. A periaortic flow probe was inserted in four of them. Measurements of cardiac output obtained with the truCCOMS catheter and with the flow probe were compared at different phases of the surgical procedure. In the intensive care unit, the cardiac output displayed by the truCCOMS monitor was compared with the value obtained after bolus injection performed subsequently. RESULTS: In the operating room (70 measurements), the coefficient of correlation between cardiac output measured by the flow probe and the truCCOMS system was r2 = 0.79, the bias was +0.11 l/min with a precision of 0.47 l/min, and limits of agreement -0.83 to +1.05 l/min. In the intensive care unit (108 measurements), the coefficient of correlation between cardiac output measured by thermodilution and the truCCOMS system was r2 = 0.56, the bias was -0.07 l/min, the precision was 0.66 l/min, and the limits of agreement were -1.39 to +1.25 l/min. CONCLUSION: The truCCOMS system is a reliable method of continuous cardiac output measurement in cardiac surgery patients.

Aorta↗

Cyclosporin A enhances interleukin-8 expression by inducing activator protein-1 in human aortic smooth muscle cells.

OBJECTIVE: Cyclosporin A (CsA) and tacrolimus (FK506) are widely used as immunosuppressants. However, their use has been hampered by various adverse effects, such as acceleration of atherosclerosis. Interleukin (IL)-8, a chemotactic cytokine, plays an important role in pathogenesis of atherosclerosis. We thus investigated whether synthesis of IL-8 from primary human aortic smooth muscle cells is influenced by CsA and FK506. METHODS AND RESULTS: Northern blot analysis revealed that CsA increased IL-8 mRNA level and enhanced its increase by epidermal growth factor or tumor necrosis factor-alpha. In contrast, FK506 had no effect on the mRNA level. IL-8 accumulation in culture media was also increased by CsA. Stability of IL-8 mRNA was not affected by CsA, whereas luciferase reporter gene assay using the human IL-8 promoter revealed that CsA significantly augmented the promoter activity. Electrophoretic mobility shift assay showed that binding activity of activator protein (AP)-1 was increased by CsA, and introduction of a mutation into the AP-1 site in the promoter abolished its CsA-dependent activation. The increased AP-1 binding activity was accompanied by c-Fos synthesis. CONCLUSIONS: CsA stimulates synthesis of IL-8 via activation of AP-1 in human aortic smooth muscle cells, providing a novel aspect of biological effects of CsA on the cells.

Aorta↗

Effects of exercise and respiration on blood flow in total cavopulmonary connection: a real-time magnetic resonance flow study.

BACKGROUND: Little is known about blood flow and its relationship to respiration during exercise in patients with total cavopulmonary connection (TCPC). METHODS AND RESULTS: We studied 11 patients 12.4+/-4.6 years (mean+/-SD) of age 5.9+/-2.8 years (mean+/-SD) after TCPC operation. Real-time MRI was used to measure blood flow in the superior vena cava (SVC), inferior vena cava (IVC), and ascending aorta under inspiration and expiration during supine lower-limb exercise (rest, 0.5 and 1.0 W/kg) on an ergometer bicycle. IVC and aortic flow increased from 1.60+/-0.52 and 2.99+/-0.83 L/min per m2 at rest to 2.58+/-0.71 and 3.97+/-1.20 L/min per m2 at 0.5 W/kg and to 3.25+/-1.23 and 4.62+/-1.49 L/min per m2 at 1.0 W/kg (P< or =0.05). SVC flow remained unchanged. Resting flow in the IVC was greater during inspiration (2.99+/-1.25 L/min per m2) than during expiration (0.83+/-0.44 L/min per m2) (inspiratory/mean flow ratio, 1.9+/-0.5), and retrograde flow was present during expiration (11+/-12% of mean flow). The predominance of inspiratory flow in IVC diminished with exercise to an inspiratory/mean flow ratio of 1.5+/-0.2 (P< or =0.05) and 1.4+/-0.3 at 0.5 and 1.0 W/kg, respectively. CONCLUSIONS: In the TCPC, circulation IVC and aortic but not SVC flows increase with supine leg exercise. Inspiration facilitates IVC flow at rest but less so during exercise, when the peripheral pump seems to be more important.

Aorta↗