Search PubMed⌕ Search

PubMed · 12876565

Semiconductor materials: From gemstone to semiconductor.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christoph E Nebel. 2003. Semiconductor materials: From gemstone to semiconductor.. https://doi.org/10.1038/nmat935

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Role of projectile and surface temperatures in the energy transfer dynamics of protonated peptide ion collisions with the diamond {111} surface.

The effects of temperature on energy transfer during collisions of protonated diglycine ions, Gly(2)-H(+), with a diamond {111} surface were investigated by chemical dynamics simulations. The simulations were performed for a collision energy of 70 eV and angle of 0 degrees with respect to the surface normal. In one set of simulations the initial surface temperature, T(surf), was varied from 300 to 2000 K, while the Gly(2)-H(+) vibrational and rotational temperatures were maintained at 300 K. For the second set of simulations the Gly(2)-H(+) vibrational temperature, T(vib), was varied from 300 to 2000 K, keeping both the Gly(2)-H(+) rotational and surface temperatures at 300 K. Increasing either the surface temperature or Gly(2)-H(+) vibrational temperature to values as high as 2000 K has, at most, only a negligible effect on the partitioning of the incident collision energy to the surface and to the vibrational and rotational modes of Gly(2)-H(+). To a good approximation, the initial surface and peptide ion energies are nearly adiabatic during the collisional energy transfer. This adiabaticity of the initial peptide ion energy agrees with experiments (J. Phys. Chem. A 2004, 108, 1). A more quantitative analysis of the effects of T(vib) and T(surf) shows there are small, but noticeable, effects on the energy transfer efficiencies. Namely, increasing the vibrational or surface temperature results in a near-linear decrease in the energy transfer to the degrees of freedom associated with this temperature.

Diamond↗

Influence of electrodes on the photon energy deposition in CVD-diamond dosimeters studied with the Monte Carlo code PENELOPE.

A new dosimeter, based on chemical vapour deposited (CVD) diamond as the active detector material, is being developed for dosimetry in radiotherapeutic beams. CVD-diamond is a very interesting material, since its atomic composition is close to that of human tissue and in principle it can be designed to introduce negligible perturbations to the radiation field and the dose distribution in the phantom due to its small size. However, non-tissue-equivalent structural components, such as electrodes, wires and encapsulation, need to be carefully selected as they may induce severe fluence perturbation and angular dependence, resulting in erroneous dose readings. By introducing metallic electrodes on the diamond crystals, interface phenomena between high- and low-atomic-number materials are created. Depending on the direction of the radiation field, an increased or decreased detector signal may be obtained. The small dimensions of the CVD-diamond layer and electrodes (around 100 microm and smaller) imply a higher sensitivity to the lack of charged-particle equilibrium and may cause severe interface phenomena. In the present study, we investigate the variation of energy deposition in the diamond detector for different photon-beam qualities, electrode materials and geometric configurations using the Monte Carlo code PENELOPE. The prototype detector was produced from a 50 microm thick CVD-diamond layer with 0.2 microm thick silver electrodes on both sides. The mean absorbed dose to the detector's active volume was modified in the presence of the electrodes by 1.7%, 2.1%, 1.5%, 0.6% and 0.9% for 1.25 MeV monoenergetic photons, a complete (i.e. shielded) (60)Co photon source spectrum and 6, 18 and 50 MV bremsstrahlung spectra, respectively. The shift in mean absorbed dose increases with increasing atomic number and thickness of the electrodes, and diminishes with increasing thickness of the diamond layer. From a dosimetric point of view, graphite would be an almost perfect electrode material. This study shows that, for the considered therapeutic beam qualities, the perturbation of the detector signal due to charge-collecting graphite electrodes of thicknesses between 0.1 and 700 microm is negligible within the calculation uncertainty of 0.2%.

Diamond↗

Notes on the construction of solid-state detectors.

BACKGROUND AND PURPOSE: Solid-state detectors such as diodes and diamonds are useful radiation detectors, particularly for small field measurements, such as in stereotactic dosimetry or in the small sub-field measurements required for intensity modulated radiotherapy (IMRT) . In all small field measurements, positioning of the detector is critical. Generally it is assumed that the center of the sensitive volume of each solid-state detector is coincident with the geometric center of the outer casing. PATIENTS AND METHODS: X-rays were taken of four detectors (diamond, three types of diode) to determine the physical characteristics of each, particularly the position of the centre of the sensitive volume. RESULTS: The results showed that the position of the centre of the sensitive volume is not always coincident with the geometric centre of a solid-state detector. CONCLUSIONS: The construction of a detector used for precise measurements should be investigated prior to use, by taking high resolution x-ray images.

Diamond↗