Search PubMed⌕ Search

PubMed · 12810025

Echo-planar rotating-frame imaging.

Abstract

A new rotating-frame imaging method that produces a complete cross section of an object in a single experiment is reported. The echo planar rotating frame imaging (EPROFI) technique uses two perpendicular RF gradients for two-dimensional spatial encoding and fully exploits the formation of rotary echoes for fast sampling of spatial frequencies. The acquisition scheme yields the Fourier transform of the spin distribution on Cartesian coordinates for straightforward image reconstruction. Implementation of the technique on a low-field portable NMR probe is described and results are presented for test objects with different geometries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Casanova, H Robert, J Perlo, D Pusiol. 2003. Echo-planar rotating-frame imaging.. https://doi.org/10.1016/s1090-7807(03)00122-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils.

PURPOSE: To examine peripheral nerve stimulation (PNS) thresholds for normal human subjects in magnetic resonance imaging (MRI) gradient coils, and determine if observed thresholds could be predicted based on gross physiologic measurements. MATERIALS AND METHODS: PNS thresholds for 21 healthy normal subjects were measured using a whole-body gradient coil. Subjects were exposed to a trapezoidal echo-planar imaging (EPI) gradient waveform and the total change in gradient strength (DeltaG) required to cause PNS as a function of the duration of the gradient switching time (tau) were measured. Correlation coefficients and corresponding P values were calculated for the PNS threshold measurements against simple physiologic measurements taken of the subjects, including weight, height, girth, and average body fat percentage, in order to determine if there were any easily observable dependencies. RESULTS: No convincing correlations between threshold parameters and gross physiologic measurements were observed. CONCLUSION: These results suggest it is unlikely that a simple physiologic measurement of subject anatomy can be used to guide the operation of MRI scanners in a subject-specific manner in order to increase gradient system performance while avoiding PNS.

Echo-Planar Imaging↗

Quantitative imaging of magnetization transfer using an inversion recovery sequence.

A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion times, and thus can be implemented on clinical imaging systems with little modification to existing pulse sequences. The sequence requires an inversion pulse with a length much longer than T(2m) (typically 10 micros) and much shorter than T(2f) (typically tens of ms) and 1/k(mf) (typically tens of ms), where T(2m) and T(2f) are the transverse relaxation times of the immobile macromolecular and free water protons, respectively, and k(mf) is the rate of MT between these populations. The resultant NMR signal is sensitive to MT when this inversion pulse affects the mobile and immobile proton pools to different degrees and by appropriate analysis of the signals obtained for different inversion times, quantitative information can be derived on the macromolecular content and exchange rates within the sample. The method has been used in conjunction with echo planar imaging to produce maps of the spatial distribution of the macromolecular content and MT rate in cross-linked bovine serum albumin. Comparisons between this method and other quantitative MT techniques are discussed.

Echo-Planar Imaging↗