Validation of dynamic MLC-controller log files using a two-dimensional diode array.

Abstract

Intensity-modulated radiation therapy (IMRT) delivered with multi-leaf collimator (MLC) in the step-and-shoot mode uses multiple static MLC segments to achieve intensity modulation. For typical IMRT treatment plans, significant numbers of segments are delivered with monitor units (MUs) of much less than 10. Verification of the ability of the linear accelerator (linac) to deliver small MU segments accurately is an important step in the IMRT commissioning and quality assurance (QA) process. Recent studies have reported large discrepancies between the intended and delivered segment MUs. These discrepancies could potentially cause large errors in the delivered patient dose. We have undertaken a systematic study to evaluate the accuracy of the dynamic MLC log files, which are created automatically by our commercial MLC workstation after each delivery, in recording the fractional MU delivered in the step-and-shoot mode. Two linac models were evaluated with simple-geometry leaf sequences and delivered with different total MUs and different nominal dose rates. A commercial two-dimensional diode array was used for the measurement. Large discrepancies between the intended and delivered segment MUs were found. The discrepancies were larger for small MU segments at higher dose rate, with some small MU segments completely undelivered. The recorded fractional MUs in the log files were found to agree with what was delivered within the limits of our experimental uncertainty. Our results indicate that it is important to verify the delivery accuracy of small MU segments that could potentially occur in a patient treatment and that the log files are useful in checking the integrity of the linac delivery once validated. Thus validated log files can be used as a QA tool for general IMRT delivery and patient-specific plan verification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonathan G Li, James F Dempsey, Li Ding, Chihray Liu, Jatinder R Palta. 2003. Validation of dynamic MLC-controller log files using a two-dimensional diode array.. https://doi.org/10.1118/1.1567951

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Retained foreign bodies from the view of the OR nurse].

Patient safety in the operating room is of high priority for the surgical team and for all healthcare workers involved. Counting procedures contribute to minimizing potential risks for the patients, especially in preventing them from leaving the operating room with retained, unintended foreign bodies. A total of 64% of operating room nurses involved in a survey are reported as having been involved in a surgical procedure in which the correct count prevented foreign bodies from being left in the patient. In addition, the strengths and potential weak points of the counting procedures could be identified. The results of the survey and drafts for a standard counting control as well as procedural recommendations are presented for discussion. A recommendation can be provided for each surgical department in order to check their own counting methods for avoiding potential risks.

Documentation↗