Search PubMed⌕ Search

PubMed · 12694847

Patient setup error measurement using 3D intensity-based image registration techniques.

Abstract

PURPOSE: Conformal radiotherapy requires accurate patient positioning with reference to the initial three-dimensional (3D) CT image. Patient setup is controlled by comparison with portal images acquired immediately before patient treatment. Several automatic methods have been proposed, generally based on segmentation procedures. However, portal images are of very low contrast, leading to segmentation inaccuracies. In this study, we propose an intensity-based (with no segmentation), fully automatic, 3D method, associating two portal images and a 3D CT scan to estimate patient setup. MATERIALS AND METHODS: Images of an anthropomorphic phantom were used. A CT scan of the pelvic area was first acquired, then the phantom was installed in seven positions. The process is a 3D optimization of a similarity measure in the space of rigid transformations. To avoid time-consuming digitally reconstructed radiograph generation at each iteration, we used two-dimensional transformations and two sets of specific and pregenerated digitally reconstructed radiographs. We also propose a technique for computing intensity-based similarity measures between several couples of images. A correlation coefficient, chi-square, mutual information, and correlation ratio were used. RESULTS: The best results were obtained with the correlation ratio. The median root mean square error was 2.0 mm for the seven positions tested and was, respectively, 3.6, 4.4, and 5.1 for correlation coefficient, chi-square, and mutual information. CONCLUSIONS: Full 3D analysis of setup errors is feasible without any segmentation step. It is fast and accurate and could therefore be used before each treatment session. The method presents three main advantages for clinical implementation-it is fully automatic, applicable to all tumor sites, and requires no additional device.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sébastien Clippe, David Sarrut, Claude Malet, Serge Miguet, Chantal Ginestet, Christian Carrie. 2003-05-01. Patient setup error measurement using 3D intensity-based image registration techniques.. https://doi.org/10.1016/s0360-3016(03)00083-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plasma levels of active ghrelin until 8 weeks after birth in preterm infants: relationship with anthropometric and biochemical measures.

This study investigated the relationship between plasma levels of ghrelin and postnatal growth in preterm infants. The levels of active ghrelin in cord blood and in plasma in 25 very low birthweight (VLBW) infants were measured. The results indicate that the levels of circulating active ghrelin markedly increases after birth in VLBW infants, and suggest that the increased levels of ghrelin reflects the maturation of ghrelin production in the stomach and an increased physiological need for ghrelin.

Anthropometry↗

A high-resolution anthropomorphic voxel-based tomographic phantom for proton therapy of the eye.

Proton therapy is increasingly used in medical treatments for cancer patients due to the sharp dose conformity offered by the characteristic Bragg peak. Proton beam interactions with the eye will be simulated using the MCNPX Monte Carlo code and available nuclear cross-section data to calculate the dose distribution in the eye gel and surrounding organs. A high-resolution eye model will be employed using a 3D geometrical voxel-based anthropomorphic head phantom obtained from the Visible Human Project (female data). Manual segmentation of the eye, carried out by the Medical Physics group at the University of Surrey resulted in 15 identified structures. This work emphasizes the use of a realistic phantom for accurately predicting dose deposition by protons.

Anthropometry↗

Phenotypic, maximum genetic, and special environmental variability in prehistoric human populations.

The phenotypic variance (V(P)) may be divided into the genetic variance (V(G)), the general environmental variance (V(Eg)), and the special environmental variance (V(Es)). The latter is estimated through repeatability calculation (b). This value is considered the upper limit of heritability and represents maximum genetic variance proportion (V(Gm) = V(G) + V(Eg)) in relation to V(P) (b = (V(G) + V(Eg))/V(P)). This process allows an improved determination of biological relationships among groups from estimators maximizing the genetic information of quantitative characters. Two hundred and thirty-seven individuals inhabiting the northern coast of Chile for 4,000 years were taken as a sample. Measurement was made of six metric characters at both sides of the cranium. Special environmental values (es) were obtained by regression. The difference between these values and the phenotypic values (p) consists in the genetic values plus the general environmental values (g + eg). A mean b value of 0.83 indicated that V(Es) represents 17% of V(P). The results showed: 1) high stability of the maximum genetic variance in time and space, 2) high correlation between the biological relationships model, the phenotypic model, and the maximum genetic model, and 3) random distribution of the nongenetic variation, as expected from the quantitative genetics theory. These results support the use of phenotypic data for the interpretation of the evolution history of prehistoric populations.

Anthropometry↗