Search PubMed⌕ Search

Biomedical subjects

Serge Miguet

Publications and source records attributed to Serge Miguet.

2 recordsLinked to original sources

Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans.

PURPOSE: We propose to simulate an artificial four-dimensional (4-D) CT image of the thorax during breathing. It is performed by deformable registration of two CT scans acquired at inhale and exhale breath-hold. MATERIALS AND METHODS: Breath-hold images were acquired with the ABC (Active Breathing Coordinator) system. Dense deformable registrations were performed. The method was a minimization of the sum of squared differences (SSD) using an approximated second-order gradient. Gaussian and linear-elastic vector field regularizations were compared. A new preprocessing step, called a priori lung density modification (APLDM), was proposed to take into account lung density changes due to inspiration. It consisted of modulating the lung densities in one image according to the densities in the other, in order to make them comparable. Simulated 4-D images were then built by vector field interpolation and image resampling of the two initial CT images. A variation in the lung density was taken into account to generate intermediate artificial CT images. The Jacobian of the deformation was used to compute voxel values in Hounsfield units. The accuracy of the deformable registration was assessed by the spatial correspondence of anatomic landmarks located by experts. RESULTS: APLDM produced statistically significantly better results than the reference method (registration without APLDM preprocessing). The mean (and standard deviation) of distances between automatically found landmark positions and landmarks set by experts were 2.7(1.1) mm with APLDM, and 6.3(3.8) mm without. Interexpert variability was 2.3(1.2) mm. The differences between Gaussian and linear elastic regularizations were not statistically significant. In the second experiment using 4-D images, the mean difference between automatic and manual landmark positions for intermediate CT images was 2.6(2.0) mm. CONCLUSION: The generation of 4-D CT images by deformable registration of inhale and exhale CT images is feasible. This can lower the dose needed for 4-D CT acquisitions or can help to correct 4-D acquisition artifacts. The 4-D CT model can be used to propagate contours, to compute a 4-D dose map, or to simulate CT acquisitions with an irregular breathing signal. It could serve as a basis for 4-D radiation therapy planning. Further work is needed to make the simulation more realistic by taking into account hysteresis and more complex voxel trajectories.

Algorithms↗

Patient setup error measurement using 3D intensity-based image registration techniques.

PURPOSE: Conformal radiotherapy requires accurate patient positioning with reference to the initial three-dimensional (3D) CT image. Patient setup is controlled by comparison with portal images acquired immediately before patient treatment. Several automatic methods have been proposed, generally based on segmentation procedures. However, portal images are of very low contrast, leading to segmentation inaccuracies. In this study, we propose an intensity-based (with no segmentation), fully automatic, 3D method, associating two portal images and a 3D CT scan to estimate patient setup. MATERIALS AND METHODS: Images of an anthropomorphic phantom were used. A CT scan of the pelvic area was first acquired, then the phantom was installed in seven positions. The process is a 3D optimization of a similarity measure in the space of rigid transformations. To avoid time-consuming digitally reconstructed radiograph generation at each iteration, we used two-dimensional transformations and two sets of specific and pregenerated digitally reconstructed radiographs. We also propose a technique for computing intensity-based similarity measures between several couples of images. A correlation coefficient, chi-square, mutual information, and correlation ratio were used. RESULTS: The best results were obtained with the correlation ratio. The median root mean square error was 2.0 mm for the seven positions tested and was, respectively, 3.6, 4.4, and 5.1 for correlation coefficient, chi-square, and mutual information. CONCLUSIONS: Full 3D analysis of setup errors is feasible without any segmentation step. It is fast and accurate and could therefore be used before each treatment session. The method presents three main advantages for clinical implementation-it is fully automatic, applicable to all tumor sites, and requires no additional device.

Anthropometry↗