Search PubMed⌕ Search

PubMed · 12553615

Porcelain-veneered computer-generated partial crowns.

Abstract

OBJECTIVE: It would be advantageous to be able to use computer-aided design and manufacturing to fabricate a restoration that can be layered with a conventional porcelain veneer in the occlusal region, thus optimizing esthetics, function, and strength. This case study reports the laboratory technique and the clinical performance of 38 partial crowns fabricated with computer technology and veneered with porcelain. METHOD AND MATERIALS: Twenty-one mandibular and 17 maxillary molars in 27 patients were prepared for partial crowns. The occlusal surfaces were lowered (1.5 to 2.0 mm), deep shoulders (1.5 mm) were prepared around the functional cusps, and 1.0-mm-deep shoulders were prepared in the proximal gingival regions. The nonfunctional cusps were prepared with an occlusal shoulder at approximately a right angle with the axial surfaces of the seat. In the computer-aided design procedure, the occlusal table was reduced to 1.4 mm above the preparation surface. The marginal ridge points, the marginal ridge line, the equator line, and the fissure line heights were adjusted accordingly. RESULTS: The lowest occlusal table thickness was 1.1 mm in six partial crowns, 1.2 mm in 26 partial crowns, and 1.3 mm in six partial crowns. The lowest occlusal table thickness of the porcelain veneers varied between 0.4 and 0.6 mm. The total occlusal table thickness thus was 1.5 mm or more. Clinically, no fractures occurred during an observation period varying between 1 and 4 years after placement. CONCLUSION: Computer-aided design and manufacturing technology is also convenient for partial crown preparation design with shoulder finish lines.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Harry W Denissen, Ahmed A El-Zohairy, Marinus A J van Waas, Albert J Feilzer. Porcelain-veneered computer-generated partial crowns.. https://pubmed.ncbi.nlm.nih.gov/12553615/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study.

OBJECTIVE: The aim of this in vitro study was to investigate, on ITI solid abutments, the retention values of single crowns fabricated using an alternative prosthetic solution: secondary cast superstructure luted to an electroformed primary coping. MATERIALS AND METHODS: Fifty standard 4.1 mm ITI implants and 5.5 mm high ITI machined abutments were assembled and mounted in acrylic resin. Implant/abutment assemblies were randomly divided into two groups. In the test group, primary galvanic caps were directly fabricated on implant abutments (A.G.C. Micro machine), and a secondary cast noble alloy superstructure was luted on each primary galvanic cap with a resin cement (Nimetic Cem). In the control group, prefabricated burn-out caps were used for casting the metal frameworks. Test and control crowns were cemented using a resin cement (Panavia 21). After storage at 37 degrees for 24 h, the specimens were subjected to a pull-out test using an Instron universal testing machine. The load required to dislodge each sample and the respective mode of failure were recorded. Means and standard deviations of loads at failure were analyzed using ANOVA. Statistical significance was set at P< or =0.05. RESULTS: The retention values (+/-SD) of loads at failure were 67.26 (+/-16.61) for the test group and 44.03 (+/-9.45) for the control group. In the test group no separation occurred between the electroformed (galvanic) primary cap and the secondary superstructure. CONCLUSIONS: The results showed that this prosthetic solution is superior on retentive performance than the conventional cast framework. An added clinical advantage of this novel method is its potential to provide a totally passive fit. Further in vitro and in vivo studies involving multiple-unit restorations are needed in order to more generally validate this prosthetic concept.

Cementation↗

Intra-operative evaluation of cementless hip implant stability: a prototype device based on vibration analysis.

Cementless implants are mechanically stabilized during surgery by a press-fitting procedure. Good initial stability is crucial to avoid stem loosening and bone cracking, therefore, the surgeon must achieve optimal press-fitting. A possible approach to solve this problem and assist the surgeon in achieving the optimal compromise, involves the use of vibration analysis. The present study aimed to design and test a prototype device able to evaluate the primary mechanical stability of a cementless prosthesis, based on vibration analysis. In particular, the goal was to discriminate between stable and quasi-stable implants; thus the stem-bone system was assumed to be linear in both cases. For that reason, it was decided to study the frequency responses of the system, instead of the harmonic distortion. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The most sensitive parameter to stability was the shift in resonance frequency of the stem-bone system, which was highly correlated with residual micromotion on all four specimens.

Cementation↗