Microfluidic actuation using electrochemically generated bubbles.

Abstract

Bubble-based actuation in microfluidic applications is attractive owing to elementary microfabrication requirements. In the present study, the mechanical and chemical characteristics of electrochemically generated bubble valves were studied. By generating electrochemical bubbles as valves directly inside the channel, valves could be closed and opened in milliseconds. Whereas bubble inflation (or valve closing) rate increases with applied voltage, small microfluidic dimensions accelerate bubble deflation rates. It is found that bubbles need not collapse fully to restore full flow, and the channel opens when its hydraulic resistance equals that between the bubble and the wall--a process requiring only milliseconds. Since only picomoles of salt are needed to generate bubbles, pH gradients that are invariably associated with electrochemical reactions were readily suppressed by using a small amount of buffer, as visualized by a pH-sensitive fluorescent dye. A range of common laboratory reagents and electrolytes in varying concentrations, including weak to strong acids and bases, as well as nonaqueous/aqueous mixtures were successfully tested. Using such bubble valves, an eight-way multiplexer was fabricated and tested.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Susan Z Hua, Frederick Sachs, David X Yang, Harsh Deep Chopra. 2002-12-15. Microfluidic actuation using electrochemically generated bubbles.. https://doi.org/10.1021/ac0259818

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of dialysate creatinine by micellar electrokinetic chromatography.

Micellar electrokinetic chromatography with UV absorbance detection has been applied for fast and selective determination of creatinine in samples of postdialysate fluid. Optimization of the method was performed, with the best results being obtained using a 30 mM borate-100 mM sodium dodecyl sulphate background electrolyte, pH 9, with the detector set at 235 nm and an applied voltage of 17 kV across a fused-silica capillary of 67 cm/75 micro m I.D. The linear range of the technique was over 2 orders of magnitude (5-1000 micro M). The developed analytical procedure is useful for the monitoring of clinical hemodialysis treatment, because creatinine levels in real undiluted samples of postdialysate range from 80 to 350 micro M. The separation system allows the analysis of about six to seven samples of spent dialysate per hour in almost real time. The determinations are not influenced by other components of dialysate fluid nor by other surrogates extracted from patient blood. The results of analysis using the developed procedure and the kinetic spectrophotometric Jaffe method conventionally used in clinical settings for creatinine determination are fully comparable. Successful clinical evaluation of the analytical system was performed. The developed system is useful for bloodless estimation of bioanalytical parameters of hemodialysis sessions such as creatinine-time profiles and total creatinine removal. Both these parameters are important in clinical models of hemodialysis therapy.

Buffers↗

Stability of ranitidine in injectable solutions.

Injectable solutions of ranitidine were prepared by dissolving ranitidine hydrochloride in water for injections. The following buffering system has been used: disodium phosphate (anhydrous), potassium dihydrogen phosphate, and phenol as a preservative. Inert gas (nitrogen) was used to displace oxygen from a solution and reduce the possibility of oxidative changes in the formulation. The solution was poured into 2-ml brown glass ampoules in asceptic condition. Ampoules samples have been stored at three different temperatures. They have been stored at 55 and 40 degrees C for 6 months, and at 25 degrees C for 12 months. TLC technique has been used for monitoring related substances, and HPLC technique for monitoring phenol and ranitidine content. It has been shown that only those samples that were stored at 25 degrees C were actually stable.

Buffers↗

Comparing micellar electrokinetic chromatography and microemulsion electrokinetic chromatography for the analysis of preservatives in pharmaceutical and cosmetic products.

In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.

Buffers↗