Search PubMed⌕ Search

PubMed · 12509039

Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes.

Abstract

Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stuart Batterman, Tricia Metts, Pentti Kalliokoski. 2002. Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes.. https://doi.org/10.1039/b204835c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption↗

Dual radiolabeling to study protein adsorption competition in relation with hemocompatibility.

Human fibrinogen (Fg) and albumin (HSA) were labeled with (3)H and (14)C, respectively. Dual counting allowed the adsorbed amount of the two proteins to be determined simultaneously. Single adsorption, adsorption of the two proteins in competition, but also exchange (substitution by molecules of the same nature) and displacement (desorption under the action of the other protein) experiments were performed on two model surfaces, glass and polystyrene (PS), as well as on pure polyvinylchloride (PVC-s) and on PVC from blood bag (PVC-b). As expected, the adsorbed amount of a single protein is higher on a hydrophobic compared to a hydrophilic surface. When the two proteins are adsorbed in competition, they are found in equal proportion on glass, while HSA is twice more abundant than Fg on PS and PVC-s and about six times more abundant on PVC-b. This trend is related to an increase of the water contact angle of the substrates. For PVC-b, the contact angle is affected by the presence of aliphatic components exposed at the extreme surface, as determined by angle-resolved X-ray photoelectron spectroscopy. In exchange and displacement experiments, the first adsorbed molecules remain dominating on PS while they can be removed from glass. Given the known importance of HSA and Fg adsorption for the fate of materials placed in contact with blood, the method described in this paper may be used as a first approach to orient the design of surfaces with improved hemocompatibility.

Adsorption↗

Effective immobilization of subunit protein in mesoporous silica modified with ethanol.

Ethoxylated FSM-type mesoporous silica (folded-sheet mesoporous material) with a pore diameter of 6.2 nm (FSM6.2) remarkably enhances rigidly of the structure in aqueous solutions. The esterified material could be used successfully as an adsorbent to accommodate subunit protein, methemoglobin (Fe(3+)). Furthermore, methemoglobin (Fe(3+)) in the pores of ethoxy-FSM is maintained a peroxidase activity similar to the native, indicating methemoglobin retains its fore subunit structure in the pores of FSM6.2.

Adsorption↗