Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Internal porosity of cast titanium removable partial dentures: influence of sprue direction and diameter on porosity in simplified circumferential clasps.

OBJECTIVE: The behavior of molten titanium in molds of complicated shape is still insufficiently understood; consequently, definite spruing criteria are not yet available for titanium RPD frameworks. This study investigated the influence of sprue design on porosity in pressure-cast titanium circumferential clasps. METHODS: The patterns of 90 circumferential clasps were sprued with three directions (0, 30 and 60 degrees , as measured between the sprue and the symmetry plane of the clasp assembly) and three sprue diameters (1.5, 2.0 and 2.5mm). CPTi was cast in a one-chamber pressure casting machine. Pore number and size were assessed on radiographs of the castings. Statistical analysis was done by two-way analysis of variance (ANOVA), followed by Fisher's PLSD post hoc test. RESULTS: The porosity in lingual arms increased significantly with increase of sprue diameter and sprue angle, while the porosity in minor connectors had an inversely proportional distribution. Very low porosity, uninfluenced by sprue design, was found in buccal arms. In conclusion, internal porosity in titanium circumferential clasp arms can be minimized through sprue design: the 0 degrees sprue direction produced the least porosity, while for the 30 and 60 degrees directions, 1.5mm diameter sprues produced lower porosity than 2.0 and 2.5mm diameter sprues. SIGNIFICANCE: In this study, the lowest porosity in titanium circumferential clasp arms was obtained with sprues attached perpendicularly to the minor connectors, regardless of sprue diameter. Conventional sprue directions produced significantly higher porosity in clasp lingual arms, the amount of porosity increasing with sprue diameter.

Analysis of Variance↗

[High-porosity and normal-porosity prostheses. Differences in growth factor release].

BACKGROUND: The majority of mid- and long-term synthetic vascular graft failures are due to anastomotic neointimal fibrous hyperplasia. The major cause of this phenomenon is the absence of an endothelial lining within prosthetic grafts. We investigated the PDGF-BB and bFGF release by umbilical vein endothelial cell cultured on precoated standard porosity or high porosity expanded polytetrafluoroethylene (ePTFE) vascular grafts. METHODS: Endothelial cell harvested from umbilical veins were cultured into standard (30 microns internodal distance) or high porosity (60 microns internodal distance) cPTFE disks. ePTFE disks uncoated or precoated with collagen type I, fibronectin and Matrigel were used and endothelial cell cultured into plastic wells coated as ePTFE disks or uncoated plastic wells served as controls. Scanning electron microscopy study assessed endothelial cell coverage. The presence of PDGF-BB and bFGF in serum-free conditioned media from endothelial cells cultured into ePTFE grafts and endothelial cell cultured into wells was determined by the inhibition antibody-binding assay 48 hours after insertion. RESULTS: Endothelial cell coverage was similar in uncoated and coated ePTFE grafts and no differences were observed between standard or high porosity grafts. The release of PDGF-BB and bFGF was significantly higher either for standard porosity or high porosity ePTFE grafts as compared with endothelial cell cultured into plastic wells (p < 0.05 and p < 0.05, respectively). The release of PDGF-BB and bFGF was independent from the various substrates either for endothelial cell cultured into standard or high porosity ePTFE grafts or plastic wells. CONCLUSIONS: Our findings pointed out that in ePTFE grafts smooth muscle cellsc proliferated only under endothelial cell at the anastomoses, along seeded synthetic grafts or in areas of transmural ingrowth where smooth muscle cells followed endothelial cell migrating into the graft. This is probably due to an alteration of the interactions between the endothelial cell, the matrices and the synthetic prosthesis.

Analysis of Variance↗

Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design.

STATEMENT OF PROBLEM: Although internal porosity is a potential risk factor for clasp fracture, little is known about its frequency in the clasps of titanium removable partial dentures. PURPOSE: This study investigated the influence of the direction of auxiliary sprues on porosity in the circumferential clasps of a pressure-cast titanium removable partial denture. MATERIAL AND METHODS: Wax patterns of a removable partial denture framework were made on 10 identical refractory casts of a Kennedy class II, modification 1, mandibular partially edentulous arch. For the auxiliary sprues directed to the circumferential clasps, 2 designs were used: straight and curved. Casting was performed in a 1-chamber pressure casting machine. Pore number and size were assessed on radiographs of the castings. The data were analyzed with the 2-tailed Student t test (P <.05). Randomly selected specimens were sectioned for morphologic observation of the internal surface of the pores. RESULTS: The number of pores >or=0.5 mm diameter and the total number of pores were significantly lower in the molar lingual arms of the curved sprue group than in the corresponding clasp arms of the straight sprue group (P =.03 and P =.009, respectively). No significant differences between the 2 groups were found for pores of any size in other locations. The pores had smooth internal surfaces. CONCLUSION: Within the limitations of this study, the curved sprue design produced significantly less porosity in the circumferential clasp arms of a cast titanium removable partial denture than the conventional straight design. The results suggest that internal porosity in titanium castings can be controlled through sprue design.

Dental Casting Technique↗

[The porosity, microhardness, roughness and internal stresses of PMMA base materials in relation to their isolation. 1. Porosity and microhardness].

Selected material properties of hot and cold polymerized denture basic materials (polymethylmethacrylate) were investigated after different methods of isolation: alginate, tin foil and silicone. Both tin foil and silicone isolation the handling of which is much easier result in a decreased portion of porosities and an increased microhardness in the PMMA.

Dental Materials↗

Changes in geometry and cortical porosity in adult, ovary-intact rabbits after 5 months treatment with LY333334 (hPTH 1-34).

The purpose of this study was to determine if the increased cortical bone porosity induced by intermittently administered parathyroid hormone (PTH) reduces bone strength significantly. Mature ovary-intact New Zealand white rabbits were treated with once daily injections of vehicle, or PTH(1-34), LY333334, at 10 or 40 microg/kg/day for 140 days. Geometry of the femoral midshaft was measured to evaluate changes in the cross-sectional moment of inertia (CSMI). Cortical porosity was measured in the midshaft of the tibia by dividing cortical area into three zones based on equal divisions of cortical diameter: near endocortical (Zone I), near intermediate (Zone II), and near periosteal (Zone III) regions. Total cortical porosity significantly increased after PTH treatment from 1.4% in the controls to 6.3% in the higher dose group, but the location of the new porosities was not randomly distributed. In the controls, porosity of Zones I and II (both 1.7%) was almost twice as much as that of Zone III (0.9%). In the lower dose group, cortical porosity of Zone I (5.5%) and II (1.8%) was greater than in Zone III (0.9%), but these differences were not statistically significant. In the higher dose group, cortical porosity of Zone I (11.5%) and II (6. 1%) significantly increased compared with Zone III (1.4%) (P < 0. 0005). Histomorphometric measurements showed that bone formation rate on both periosteal and endocortical surfaces increased, resulting in increased bone area and cortical area in the higher dose group. A model was developed to evaluate the effect of the changes in geometry and porosity on CSMI in the different zones. This simulation model indicated that CSMI in the higher dose group was significantly greater than in the other two groups, despite the increased porosity. We speculate the reason to be that porosity increased near the endocortical surface, where its mechanical effect is small. This increase was more than offset by apposition of new bone on the periosteal surface. These data suggest that (1) PTH increases cortical porosity in a dose-dependent manner, primarily near endocortical surfaces; (2) because of this nonhomogeneous distribution, the mechanical effect of increased porosity is small; (3) the increased cortical porosity associated with PTH treatment is more than offset by periosteal apposition of new bone, causing an overall increase in the bending rigidity of cortical bone; and (4) these changes cannot be accurately evaluated using noninvasive methods of bone densitometry, which cannot account for the location of bone gain and bone loss.

Animals↗

Evaluation of porosity in microwave-processed acrylic resin using a photographic method.

STATEMENT OF PROBLEM: The effect of microwave polymerization on the porosity of denture base resin has not been fully determined. PURPOSE: This study investigated the effect of microwave energy on the porosity of 2 heat-activated denture base resins. MATERIAL AND METHODS: Two heat-activated denture base resins, one conventional (Paladon 65) and one designed for microwave polymerization (Acron MC), were used to prepare 50 test specimens. Five groups of 10 specimens each were established: Group A (Paladon 65, water bath); Group B(1) (Paladon 65, short microwave cycle); Group B(2) (Paladon 65, long microwave cycle); Group C(1) (Acron MC, short microwave cycle); and Group C(2) (Acron MC, long microwave cycle). Half of the specimens in each group were 3 mm thick, the other half 6 mm thick. After being polymerized, specimens were cut so that 3 cross-sectional areas were formed (S(1), S(2), and S(3)). These surfaces were polished and photographed under a microscope at x100 magnification. On the developed photographs, the area of each pore was measured with a digital planimeter, and the total area of pores per surface was calculated in percentage form. The total number of pores on each surface and the topographical distribution of the pores also were recorded. A 3-factor repeated-measures analysis of variance was used to compare porosity data, and a 1-way analysis of variance was performed to determine possible interactions between groups based on material and specimen thickness (P<.05). The effect of surface area on porosity data was analyzed with the use of contrasts. RESULTS: Group A specimens exhibited no pores. In the thicker specimens of Groups B(1) and B(2), giant pores (area as great as 3.69 mm(2)) and small, gaseous pores of almost uniform shape and size were found. In Groups C(1) and C(2), only the smaller pores were found; these were not clinically significant. Of the observed surfaces, 75.3% were free of pores and 24.7% contained at least one pore. In a selected group of pore-bearing surfaces, the majority (81%) had pores located near the center. The thicker specimens in Group B exhibited the greatest amount of porosity (P<.0001); Group C specimens exhibited the least porosity. Repeated-measures analysis of variance showed that polymerization cycle had no effect on porosity (P=.19). The 3 other factors (material, specimen thickness, and surface) and all possible interactions among them were significant (P<.05). Among the surfaces, S(1) and S(2) exhibited the highest total mean value of porosity (0.71% and 0.74%, respectively) and S(3) the lowest (0.025%). S(3) showed a different pattern of porosity than S(1) and S(2). CONCLUSION: Within the limitations of this in vitro study, minor porosity was identified in thin and more severe porosity in thicker areas of conventional resin specimens that underwent microwave polymerization. The resin designed specifically for microwave polymerization exhibited no clinically significant porosity.

Acrylic Resins↗

Prediction of tablet hardness and porosity using near-infrared diffuse reflectance spectroscopy as a nondestructive method.

The main objective of this research is to use the near-infrared diffuse reflectance method to evaluate and quantify the effects of hardness and porosity on the near-infrared spectras of tablets. To develop a model equation, validate the model and test the model predictive ability. Seven theophylline tablet formulations of the same composition but with seven different hardness values (3, 6, 8, 10, 12, 15, and 17 kp) were prepared. Another seven theophylline tablets formulation with seven different porosity values (57.4, 50.3, 41.9, 40.3, 39.9, 37.3, and 35.1%) were prepared. Five placebo tablets formulation with different hardness and porosity values were also prepared. Laboratory hardness and porosity values were compared to near-infrared diffuse reflectance data. Linear regression, quadratic, cubic and partial least square techniques were used to determine the relationship between hardness, porosity and the near-infrared spectras. The results demonstrated that an increase in tablet hardness and a decrease in tablets porosity produced an increase in near-infrared absorbance. Series of model equations depending on the mathematical technique used for regression were developed from the calibration of hardness and porosity data using laboratory equipment vs. the near-infrared diffuse reflectance for each formulations. The results of near-infrared hardness and porosity predictions were very similar to laboratory hardness and porosity tests. The near-infrared diffuse reflectance spectroscopy method is an alternative nondestructive method for measurement of hardness and porosity of tablets.

Cellulose↗

Electrical conductivity of lumbar anulus fibrosis: effects of porosity and fixed charge density.

STUDY DESIGN: Experimental investigation of the electrical conductivity of normal and trypsin-treated lumbar anulus fibrosis specimens. OBJECTIVES: To measure the electrical conductivity of intervertebral disc tissues and to study the effects of tissue porosity (volume fraction of water) and fixed charge density on the electrical conductivity of anulus fibrosis in physiologic saline. SUMMARY OF BACKGROUND DATA: Specific electrical conductivity is one of the material properties of intervertebral discs. Their value depends on ion concentrations and ion diffusivities within the tissue, which in turn are functions of tissue composition and structure. To our knowledge, the electrical conductivity of intervertebral discs has not been studied. Investigation of the electrical conductivity of intervertebral discs and understanding of their relationship to tissue porosity and fixed charge density will provide insights into electromechanical phenomena (e.g., streaming potential) and ion transport in intervertebral discs. METHODS: A total of 35 porcine lumbar anulus fibrosis specimens were divided into two groups: one control group (n = 10) and one trypsin-treated group (n = 25). The specimens in the control group were subjected to one-dimensional free swelling in phosphate-buffered saline (pH 7.4), and electrical conductivity and porosity (water content) were measured over a period of about 45 minutes. The specimens in the treated group were immersed in a trypsin solution (372 U/mL phosphate-buffered saline) for 45 minutes at room temperature, and the electrical conductivity and porosity were measured after treatment. The electrical conductivity was correlated to tissue porosity for the control and treated specimens. The influences of porosity and fixed charge density were studied. RESULTS: The average value for control specimens was 5.60 +/- 0.89 mS/cm (mean +/- SD; n = 10) before swelling and 9.11 +/- 0.90 mS/cm (mean +/- SD; n = 10) after swelling. Tissue porosity increased from 0.74 +/- 0.03 (mean +/- SD; n = 10) before swelling to 0.83 +/- 0.02 (mean +/- SD; n = 10) after swelling. The trypsin treatment reduced anulus fibrosis porosity by 3.6% (P < 0.05) and conductivity by 13% (P < 0.05) compared to those for control specimens after swelling. No significant changes werefound in wet and dry tissue densities between control and treated groups. There was a significant, linear correlation between conductivity and porosity for control anulus fibrosis specimens (R2 = 0.87; 86 measurements). CONCLUSIONS: Measured electrical conductivity was sensitive to tissue porosity, but not to fixed charged density for anulus fibrosis specimens in phosphate-buffered saline.

Animals↗

Teriparatide [PTH(1-34)] strengthens the proximal femur of ovariectomized nonhuman primates despite increasing porosity.

UNLABELLED: OVX monkeys treated for 18 months with 1 or 5 microg/kg/d teriparatide [PTH (1-34)] had significantly stronger proximal femora relative to ovariectomized controls. Teriparatide enhancement of cortical area, cortical width, and trabecular bone volume seemed to more than compensate for the dose-dependent increase in cortical porosity. Beneficial effects of teriparatide treatment on the proximal femur persisted beyond the treatment period and may extend to the marrow. INTRODUCTION: We conducted a detailed quantitative analysis of the effects of teriparatide on the proximal femur of ovariectomized monkeys. Teriparatide increased bone mass, enhanced structural architecture, and strengthened the hip, despite increasing cortical porosity. MATERIALS AND METHODS: Monkeys were treated with vehicle (sham or OVX controls), 1 microg/kg/day teriparatide [parathyroid hormone (1-34); PTH1], or 5 microg/kg/day teriparatide (PTH5) for 18 months or for 12 months followed by 6 months of treatment withdrawal (PTH1W and PTH5W, respectively). Excised proximal femora were analyzed by microCT, conventional histomorphometry, and biomechanics. RESULTS AND CONCLUSIONS: The femoral neck showed significant reduction in trabecular bone volume (BV/TV) for OVX compared with sham, whereas PTH1 BV/TV was restored to sham levels and PTH5 BV/TV was greater than sham and OVX. The withdrawal groups had BV/TVs intermediate between sham and OVX. PTH1 had trabecular number (Tb.N) greater than OVX, and PTH5 Tb.N was greater than sham and OVX. The withdrawal groups had Tb.Ns intermediate between sham and OVX. No differences between groups were observed for trabecular orientation or trabecular thickness. Teriparatide dose-dependently increased bone formation rate and activation frequency in the femoral neck. Cellular composition analyses suggested a tendency of ovariectomy to increase adiposity of marrow by 100%, whereas PTH tended to reduce adipocyte number and increase osteoblast number compared with OVX. Analyses of the cortex showed dose-dependent elevation of cortical porosity, which was consistent with enhanced bone turnover with treatment. Cortical porosity was reduced after withdrawal of teriparatide, because PTH1W cortical porosity was lower than OVX, whereas PTH5W cortical porosity was intermediate between sham and OVX. Increased cortical porosity did not weaken the proximal femora. Biomechanics showed that ovariectomy weakened proximal femora compared with sham, but PTH1, PTH5, and PTH1W were stronger than OVX and not different from sham. PTH5W strength was intermediate between sham and OVX. Therefore, teriparatide had beneficial effects on the proximal femur, despite increasing cortical porosity. Cortical porosity did not adversely affect the mechanical integrity of the proximal femora, because enhanced cortical area and trabecular bone volume more than compensated for the porosity. Much of the beneficial effects of teriparatide were retained after 6 months withdrawal from treatment. PTH effects on the femoral neck were not limited to bone but may include inhibition of OVX-stimulated adiposity of the marrow.

Animals↗

Intermittently administered human parathyroid hormone(1-34) treatment increases intracortical bone turnover and porosity without reducing bone strength in the humerus of ovariectomized cynomolgus monkeys.

Cortical porosity in patients with hyperparathyroidism has raised the concern that intermittent parathyroid hormone (PTH) given to treat osteoporotic patients may weaken cortical bone by increasing its porosity. We hypothesized that treatment of ovariectomized (OVX) cynomolgus monkeys for up to 18 months with recombinant human PTH(1-34) [hPTH(1-34)] LY333334 would significantly increase porosity in the midshaft of the humerus but would not have a significant effect on the strength or stiffness of the humerus. We also hypothesized that withdrawal of PTH for 6 months after a 12-month treatment period would return porosity to control OVX values. OVX female cynomolgus monkeys were given once daily subcutaneous (sc) injections of recombinant hPTH(1-34) LY333334 at 1.0 microg/kg (PTH1), 5.0 microg/kg (PTH5), or 0.1 ml/kg per day of phosphate-buffered saline (OVX). Sham OVX animals (sham) were also given vehicle. After 12 months, PTH treatment was withdrawn from half of the monkeys in each treatment group (PTH1-W and PTH5-W), and they were treated for the remaining 6 months with vehicle. Double calcein labels were given before death at 18 months. After death, static and dynamic histomorphometric measurements were made intracortically and on periosteal and endocortical surfaces of sections from the middiaphysis of the left humerus. Bone mechanical properties were measured in the right humeral middiaphysis. PTH dose dependently increased intracortical porosity. However, the increased porosity did not have a significant detrimental effect on the mechanical properties of the bone. Most porosity was concentrated near the endocortical surface where its mechanical effect is small. In PTH5 monkeys, cortical area (Ct.Ar) and cortical thickness (Ct.Th) increased because of a significantly increased endocortical mineralizing surface. After withdrawal of treatment, porosity in PTH1-W animals declined to sham values, but porosity in PTH5-W animals remained significantly elevated compared with OVX and sham. We conclude that intermittently administered PTH(1-34) increases intracortical porosity in a dose-dependent manner but does not reduce the strength or stiffness of cortical bone.

Animals↗

Directional porosity of porcine small-intestinal submucosa.

Small-intestinal submucosa (SIS) has been shown to be a promising biomaterial for vascular graft applications. This study examines the directionality property of SIS porosity using 35 SIS specimens from 13 pigs. In addition, the effects of the weight of the donor pig, pre-conditioning of 13 additional SIS specimens, and the duration of the test of five additional SIS specimens on such porosity are reported. The porosity from serosal to mucosal direction was found to be four times greater than the porosity in the opposite direction. The weight of the donor pig was not found to be an important factor in SIS porosity. Preconditioning served to increase the average serosal porosity index at 120 mm Hg static water pressure from 2.99 to 8.33 mL/(min cm2). The porosity in the mucosal direction was not affected by preconditioning. Porosity in both directions decreased with increasing test duration. The directionality property of SIS porosity may be an important factor in its success as a vascular graft. The term 'porosity' is used throughout this article, but current standards also refer to the term 'permeability' to describe the passage of liquid through a vascular graft.

Animals↗

Composite porosity of expanded polytetrafluoroethylene vascular prosthesis.

Polytetrafluoroethylene (PTFE) prostheses were modified to produce two types of composite porosity PTFE grafts: type I--inner 60 microns/outer 20 microns and type II--inner 20 microns/outer 60 microns. These composite porosity PTFE designs were investigated for bleed through, graft healing and patency and compared with high porosity PTFE (60 microns) and standard PTFE (20 microns) grafts. The grafts were implanted into the carotid and femoral arteries of dogs and retrieved after 4, 12 and 18 weeks. Both composite porosity grafts showed significantly less bleed through than standard and high porosity grafts after reperfusion. In composite grafts, the 60-microns layer allowed fibrovascular tissue and histiocyte ingrowth from perigraft tissue, but the 20-microns layer did not. Neointima formation occurred earlier and endothelialization was more extensive in high porosity grafts, but seroma formation occurred in 25% of cases. In type I composite porosity grafts, smooth muscle cells of neointima migrated into the pores of the graft, providing a firmly anchored intima. Type II composite porosity grafts allowed better ingrowth of fibrovascular tissue at the outer layer from the perigraft tissue; however, endothelialization was not completed. Composite porosity grafts should be considered for evaluation in specific clinical situations.

Animals↗

The effect of shape and porosity on the compression behaviour and tablet forming ability of granular materials formed from microcrystalline cellulose.

The compression behaviour of two types of granules prepared from microcrystalline cellulose was evaluated. Three sets (low, intermediate and high intragranular porosity) of irregular granules and three sets of nearly spherical granules (called pellets) were prepared from microcrystalline cellulose by wet agglomeration or wet agglomeration followed by extrusion/spheronisation. The granules and pellets were similar in size. The range of intragranular porosity, although wide, was also similar for both types. The compression behaviour was evaluated in terms of the degree of compression, the appearance of the tablets and the size distribution of retrieved aggregates (after deaggregation). The compactability of the granules and pellets was also studied. Both types of granules kept their integrity during compression. The dominant mechanism during compression appeared to be permanent deformation. However, during compression of high porosity granules, fragmentation or attrition seemed to occur alongside deformation. Tablets formed from granules had a closer pore structure than those formed from pellets of equal intragranular porosity and the granules seemed to deform to a higher degree during compression. The total tablet porosity was almost independent of the intragranular porosity and the shape of the granules before compression. It is suggested that the degree of granule deformation was controlled by the intragranular porosity and voidage of each bed of granules before compression. The tensile strength of the tablets was also dependent on the porosity and the shape of the granules; tablets formed from irregular granules were stronger than those formed from pellets of an equal intragranular porosity.

Cellulose↗

Evaluation of prosthetic grafts of different porosity for arterial reconstruction.

Autogenous jugular veins and Dacron grafts of different porosities were implanted as short bypass grafts around ligated femoral arteries in the dog. Patency rates for periods up to eight months were: vein, 79 per cent; DeBakey Dacron (lowest porosity), 39 per cent; Wesolowski Weavenit (imtermediate porosity), 56 per cent; high porosity Dacron, 8 per cent. The failure of sixteen of the twenty-four high porosity grafts was related to perigraft hematomas that occurred two to seven days after operation and later thrombosis. The higher the porosity of the graft, the better the healing pattern as evidenced by fibrous bonding of the inner and outer linings of the grafts through the interstices. In the spectrum of grafts with increasing porosity there is apparently an optimal porosity beyond which late bleeding counterbalances the better healing properties of the higher porosity graft.

Animals↗

Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosity.

The importance of porosity in synthetic arterial graft healing has not been adequately defined. To determine the effect of porosity on graft healing, we measured the extent of cellular response at late times in 4 mm internal diameter polytetrafluoroethylene grafts of varying porosity (between 10 and 90 microns internodal distance) inserted into the arterial system of baboons. After 1 and 3 months the grafts were retrieved and examined for endothelial coverage, intimal thickening, and endothelial cell and smooth muscle cell proliferation. The pattern of intimal healing with endothelial cells and smooth muscle cells was only related to porosity in the sense that there was an abrupt switch in the pattern of healing as porosity was increased from 30 to 60 microns. In low porosity grafts (10 and 30 microns internodal distances) endothelial coverage of the luminal surface was incomplete and, along with intimal thickening, was limited to graft near the anastomosis. In high porosity grafts (60 and 90 microns internodal distances) luminal endothelial coverage was complete, and intimal thickening was uniformly distributed throughout the graft. The highest porosity graft studied (90 microns) developed areas of focal loss of endothelial cells at late time periods. In this limited series there does appear to be an optimal porosity for polytetrafluoroethylene grafts near 60 microns, since 10 and 30 micron grafts fail to achieve luminal endothelial cell coverage, and 90 micron grafts exhibit instability of the intima with focal endothelial cell loss.

Animals↗