Abstract

Complex degree of coherence functions are computed using synthetic and measured ultrasound data to demonstrate noteworthy aspects of coherence analysis in the context of aberration correction. Coherence functions calculated from synthetic data illustrate the importance of proper normalization of the constituent cross-correlation integrals when weak elements and receiver directivity are significant factors. The synthetic data also show that a spike can occur at the zero-lag position of the coherence function when the signal-to-noise ratio is reduced by element directivity near the edges of a large aperture. The latter observation is confirmed by experimental data acquired through tissue-mimicking distributed aberration phantoms using a low f-number two-dimensional array system. The coherence of data acquired at neighboring elements is not changed by time-shift compensation of transmit and receive focusing, but time-shift compensation does improve the coherence of echoes measured over larger separations. The resulting increase in coherence widths evaluated at levels between 0.2 and 0.5 is correlated with narrower -10 dB and -20 dB effective widths in focuses visualized using single-transmit images. Iterative focus compensation methods may benefit from aberration estimation algorithms that take advantage of these longer-range correlations in random-scattering waveforms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James C Lacefield, Robert C Waag. 2002. Spatial coherence analysis applied to aberration correction using a two-dimensional array system.. https://doi.org/10.1121/1.1511756

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗