Search PubMed⌕ Search

PubMed · 12486512

Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.

Abstract

BACKGROUND: Our objective was to develop a three-dimensional high-resolution ultrasonic imaging technique to be utilized for in-vivo characterization of the ciliary body and the posterior iris. The benefit of this imaging in enhancing the quantification of the configurational changes in the ciliary body during accommodation is demonstrated. METHODS: Sequential ultrasound biomicroscopic images of the ciliary body region were obtained with a computer-controlled scanning device designed for use with a standard ultrasound biomicroscope for 3D imaging. Custom-made software allows online data collection, data analysis and 3D reconstruction in conjunction with commercially available VoxelView software. RESULTS: The three-dimensional presentation allows a close approximation of the ciliary muscle inside the ciliary body in vivo. We are able to distinguish and to analyze the changes in the muscle contour in different accommodation states. During accommodation a shift in the ciliary muscle center of gravity in a range of 0.04-0.26 mm (mean 0.13+/-0.06 mm) in the direction of the lens equator, with an interindividual variation and a small decrease with age, was observed. CONCLUSIONS: High-resolution ultrasound is a well established technique for in-vivo investigation of the anterior segment. Three-dimensional ultrasound biomicroscopy allows an assessment of the individual ciliary muscle activity in consideration of the ciliary processes. In combination with a contour analysis tool we improved the muscle contour determination during different accommodation states. The investigation showed an activity of the ciliary muscle in young volunteers as well as those of presbyopic age.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Oliver Stachs, Heiner Martin, Alexander Kirchhoff, Joachim Stave, Thom Terwee, Rudolf Guthoff. 2002-10-09. Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.. https://doi.org/10.1007/s00417-002-0551-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗