Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement.

Dislocation remains a serious complication of total hip replacement. An insufficient range of motion can lead to impingement of the prosthetic neck on the acetabular cup. Together with the initiation of subluxation and dislocation, recurrent impingement can cause material failure in the liner. The objective of this study was to generate a validated finite element (FE) model capable of predicting the dislocation stability of different femoral head sizes with regard to impingement in different implant positions as well as the corresponding stress distribution in the liner. In order to cover posterior and anterior dislocation, two total hip dislocation associated manoeuvres were simulated using a three-dimensional nonlinear finite element model. The dislocation stability of two head sizes was determined numerically and experimentally. After validation, the FE model was used to analyse the dislocation stability of four different head sizes in variable implant positions. Range of motion (ROM) until impingement, the resisting moment that was developed and ROM until dislocation were evaluated. Additionally, stress distribution within the polyethylene liner during impingement and subluxation was determined. For both dislocation modes, a cup position of 45 degrees lateral abduction and 15 degrees up to 30 degrees anteversion resulted in appropriate ROM and dislocation stability. In general, larger head diameters revealed an increase in ROM and higher resisting moments. Stress analysis showed decreased contact pressures at the egress site of the liners with the larger inner diameters during subluxation. The analysis shows that an optimal implant position and a larger head diameter can reduce the risk of dislocation induced by impingement. The finite element model that was developed enables simplification of design variations compared to experimental studies since prototyping and assembling are replaced by prompt numerical simulation.

Arthroplasty, Replacement, Hip↗

Three-dimensional ultrasound biomicroscopy, environmental and conventional scanning electron microscopy investigations of the human zonula ciliaris for numerical modelling of accommodation.

PURPOSE: Biomechanical modelling of the accommodation process is a useful tool for studying the mechanism of accommodation and presbyopia and can aid in the development of accommodative lens-replacing materials. Existing biomechanical models, however, use a very simplified zonula structure. The aim of this study was to use three-dimensional ultrasonic imaging and scanning electron microscopy to provide a more detailed, three-dimensional description of the structure of the human zonula to improve the modelling of accommodation. METHODS: Five human eyes were examined without invasive manipulation using a custom-made three-dimensional ultrasonic imaging technique that allows scanning of features with a spatial resolution of 30 microm. Environmental and conventional scanning electron microscopy (SEM) provided information to complement the ultrasonic images for use in development of a more anatomically correct finite-element model of the zonula structures. These data along with the material properties of the ocular tissue structures were used to construct an advanced geometric model for finite-element simulation of the accommodation process. RESULTS: Images were obtained through three-dimensional ultrabiomicroscopy (3D-UBM) of anatomical features heretofore not directly imagable in their native state. Ciliary processes and zonula structures were clearly separated by both the 3D-UBM and the SEM methods. It was found that fibres inserting on the anterior and posterior lens capsule emerge anteriorly at the ciliary body. Fibres emerging near the pars plana insert on the lens and the ciliary body. No X-shaped crossing fibres were found. Modelling of the accommodation process with both the simple and the more complex geometric models produced refractive power changes comparable with in vivo findings. CONCLUSIONS: The 3D-UBM allowed examination of zonula structures in their native state with minimized preparation artefacts. While these data were incorporated into a complex and more anatomically correct finite-element simulation of intraocular features including lens, zonular system and ciliary body it was found that a simplified zonular model is sufficient for the numerical simulation of the accommodation process.

Accommodation, Ocular↗

Comparison of the accommodation theories of Coleman and of Helmholtz by finite element simulations.

PURPOSE: The accommodation process of the human eye is still a controversial subject. Coleman assumes that the lens, together with the zonula fibers, forms a diaphragm which is held in a catenary shape due to the pressure difference between the aqueous and vitreous body of the lens. The aim of the paper is to compare the results of two simulations (according to the Helmholtz and to the Coleman theories) with ultrasonographic data. METHODS: An axisymmetric static finite element model of the lens was generated using the literature data for geometry, material properties and loads. The refractive power of the lens was calculated for two different ages (29 and 45 years). RESULTS: The application of a pressure to the posterior lens surface did not yield an increase in refractive power change during accommodation. Rather a decrease in accommodation related refractive power was found. CONCLUSIONS: Physiologically relevant refractive power changes are obtained by a simulation in accordance with the Helmholtz theory. A simulation in accordance with the Coleman theory does not yield physiological values of refractive power change.

Accommodation, Ocular↗

The cause of subchondral bone cysts in osteoarthrosis: a finite element analysis.

BACKGROUND: The etiology of subchondral bone cysts in arthrotic joints is unclear. MATERIALS AND METHODS: We used two-dimensional finite element analysis to evaluate the hypothesis that subchondral bone cysts in the osteoarthrotic hip joint may be the result of microfractures caused by localized cartilage defects or a thinned layer of cartilage. We evaluated the equivalent bone stress (von Mises (VM) stress) in the cancellous bone as an indicator of potential microfractures and further development of cystic lesions. RESULTS: Cartilage defects induced stress peaks in the subchondral bone. This peak stress distribution corresponded to the clinical observation of development of acetabular and femoral subchondral cysts in a "kissing" position. A femoral subchondral bone cyst induced a stress peak at the corresponding acetabular site, whereas subchondral acetabular cysts did not increase stress in the femoral head. Acetabular cysts showed an increased level of stress at the lateral and medial border of the lesion which was much higher than the stress levels in the femoral head, indicating a tendency to faster growth. INTERPRETATION: Our study supports the theory that stress-induced bone resorption may cause development of subchondral bone cysts in osteoarthrosis.

Acetabulum↗

Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.

BACKGROUND: Our objective was to develop a three-dimensional high-resolution ultrasonic imaging technique to be utilized for in-vivo characterization of the ciliary body and the posterior iris. The benefit of this imaging in enhancing the quantification of the configurational changes in the ciliary body during accommodation is demonstrated. METHODS: Sequential ultrasound biomicroscopic images of the ciliary body region were obtained with a computer-controlled scanning device designed for use with a standard ultrasound biomicroscope for 3D imaging. Custom-made software allows online data collection, data analysis and 3D reconstruction in conjunction with commercially available VoxelView software. RESULTS: The three-dimensional presentation allows a close approximation of the ciliary muscle inside the ciliary body in vivo. We are able to distinguish and to analyze the changes in the muscle contour in different accommodation states. During accommodation a shift in the ciliary muscle center of gravity in a range of 0.04-0.26 mm (mean 0.13+/-0.06 mm) in the direction of the lens equator, with an interindividual variation and a small decrease with age, was observed. CONCLUSIONS: High-resolution ultrasound is a well established technique for in-vivo investigation of the anterior segment. Three-dimensional ultrasound biomicroscopy allows an assessment of the individual ciliary muscle activity in consideration of the ciliary processes. In combination with a contour analysis tool we improved the muscle contour determination during different accommodation states. The investigation showed an activity of the ciliary muscle in young volunteers as well as those of presbyopic age.

Accommodation, Ocular↗