Search PubMed⌕ Search

PubMed · 12418665

Predicting diffused-bubble oxygen transfer rate using the discrete-bubble model.

Abstract

A discrete-bubble model that predicts the rate of oxygen transfer in diffused-bubble systems is evaluated. Key inputs are the applied gas flow rate and the initial bubble size distribution. The model accounts for changes in the volume of individual bubbles due to transfer of oxygen and nitrogen (and hence changing partial pressure), variation in hydrostatic pressure, and changes in temperature. The bubble-rise velocity and mass-transfer coefficient, both known functions of the bubble diameter, are continually adjusted. The model is applied to predict the results of diffused-bubble oxygen transfer tests conducted in a 14-m deep tank at three air flow rates. All of the test data are predicted to within 15%. The range of bubble diameters (0.2-2 mm) spans the region of greatest variation in rise velocity and mass-transfer coefficient. For simplicity, the Sauter-mean diameter is used rather than the full bubble size distribution without loss of accuracy. The model should prove useful in the design and optimization of hypolimnetic oxygenation systems, as well as other diffused-bubble applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel F McGinnis, John C Little. 2002. Predicting diffused-bubble oxygen transfer rate using the discrete-bubble model.. https://doi.org/10.1016/s0043-1354(02)00175-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Calibration and evaluation of nitric acid and ammonia permeation tubes by UV optical absorption.

An ultraviolet (UV) optical absorption system has been developed for absolute calibrations of nitric acid (HNO3) and ammonia (NH3) permeation tube emission rates. Using this technique, dilute mixtures containing NH3 or HNO3, both of which interact strongly with many surfaces, are accurately measured at levels below a part per million by volume. This compact and portable instrument operates continuously and autonomously to rapidly (<1 h) quantify the emission of trace gases from permeation devices that are commonly used to calibrate air-monitoring instruments. The output from several HNO3 and NH3 permeation tubes, with emission rates that ranged between 13 and 150 ng/min, was examined as a function of temperature, pressure, and carrier gas flow. Absorptions of 0.015% can be detected which allows a precision (3sigma) of +/-1 ng/min for the HNO3 and NH3 permeation tubes studied here. The accuracy of the measurements, which relies on published UV absorption cross sections, is estimated to be +/-10%. Measurements of permeation tube emission rates using ion chromatography analysis are made to further assess measurement accuracy. The output from the HNO3 and NH3 permeation tubes examined here was stable over the study period, which ranged between 3 months and 1 year for each permeation tube.

Air Movements↗

Simulation of an orifice scrubber performance based on Eulerian/Lagrangian method.

A mathematical model based on Eulerian/Lagrangian method has been developed to predict particle collection efficiency from a gas stream in an orifice scrubber. This model takes into account Eulerian approach for particle dispersion, Lagrangian approach for droplet movement and particle-source-in-cell (PSI-CELL) model for calculating droplet concentration distribution. In order to compute fluid velocity profiles, the normal k-epsilon turbulent flow model with inclusion of body force due to drag force between fluid and droplets has been used. Experimental data of Taheri et al. [J. Air Pollut. Control Assoc. 23 (11) (1973) 963] have been used to test the results of the mathematical model. The results from the model are in good agreement with the experimental data. After validating the model the effect of operating parameters such as liquid to gas flow rate ratio, gas velocity at orifice opening, and particle diameter were obtained on the collection efficiency.

Air Movements↗

Numerical simulation of gas flow around a passive vent in a sanitary landfill.

A numerical model, based on the Darcy law, was used to simulate the two-dimensional gas flow around a passive vent in a sanitary landfill. We follow Findikakis and Leckie [ASCE J. Environ. Eng. 105 (1979) 927] in modeling the biodegradation of the solid waste and assume the first-order biodegradation kinetics. The numerical results from the Fresh Kills landfill, New York, show that the well's ability in extracting the landfill gas by the passive vent decays quickly with the increase of the radial distance from the well. The influence radius of the well is generally less than 20 m. The effects from the final soil thickness, well depth, and other parameters on the gas flow are also discussed.

Air Movements↗