Predicting diffused-bubble oxygen transfer rate using the discrete-bubble model.

A discrete-bubble model that predicts the rate of oxygen transfer in diffused-bubble systems is evaluated. Key inputs are the applied gas flow rate and the initial bubble size distribution. The model accounts for changes in the volume of individual bubbles due to transfer of oxygen and nitrogen (and hence changing partial pressure), variation in hydrostatic pressure, and changes in temperature. The bubble-rise velocity and mass-transfer coefficient, both known functions of the bubble diameter, are continually adjusted. The model is applied to predict the results of diffused-bubble oxygen transfer tests conducted in a 14-m deep tank at three air flow rates. All of the test data are predicted to within 15%. The range of bubble diameters (0.2-2 mm) spans the region of greatest variation in rise velocity and mass-transfer coefficient. For simplicity, the Sauter-mean diameter is used rather than the full bubble size distribution without loss of accuracy. The model should prove useful in the design and optimization of hypolimnetic oxygenation systems, as well as other diffused-bubble applications.

Air Movements↗

Predicting oxygen transfer and water flow rate in airlift aerators.

Water flow rate, gas-phase holdup, and dissolved oxygen (DO) profiles are measured in a full-scale airlift aerator as a function of applied air flow rate. A model that predicts oxygen transfer based on discrete-bubble principles is applied. The riser DO profiles are used to calculate the initial bubble size. The range of calculated bubble diameters obtained using the model is 2.3-3.1 mm. The Sauter-mean diameter of bubbles measured in the laboratory ranged from 2.7 to 3.9 mm. The riser and downcomer DO profiles and gas holdups predicted by the model are in close agreement with the experimental results. A model that predicts water flow rate based on an energy balance is used to calculate Kt, the frictional loss coefficient for the air-water separator. Excluding the data at the very lowest air flow rate, the range of calculated values for Kt (3-8) is close to a literature value of 5.5 proposed for hydrodynamically similar external airlift bioreactors. The models should prove useful in the design and optimization of airlift aerators.

Air Movements↗