Search PubMed⌕ Search

PubMed · 12201415

Output variation from an intensity modulating dynamic collimator.

Abstract

Intensity modulated radiation therapy (IMRT) offers a method of delivering radiation dose conforming to the shape of targets while minimizing the dose to the surrounding tissue and nearby critical organs. One popular device is the NOMOS MIMiC Collimator coupled to the CORVUS treatment planning system. The MIMiC collimator, mounted on a linac head, opens and closes one or more of its 40 small leaves as determined by the planner while the linac delivers radiation and the gantry rotates. This dynamic IMRT allows the intensity to be modulated yielding a highly conformal dose distribution. However, the dose output becomes a function of the detailed manner in which the leaves open and close, since the opening and closing are not instantaneous. We investigate the effect of switch rates and delay in the open/close events on the output profiles. The output is enhanced as the switch rate increases. The enhancement factor at any point of measurement is dependent on its distance from the central plane. We interpret these variations in terms of a simple model, which includes the effect of leaf travel time during the process of opening and closing. We also include the time delay in establishing the specified pressure in the pneumonic device, which controls the opening and closing of the leaves. The information presented here offers a means for incorporating these output changes into the planning system. This may avoid the current situation where many patient plans need to be renormalized based on the actual measurement taken during the delivery of the specified intensity pattern to a phantom.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Murshed Hossain, Christopher J Houser, James M Galvin. 2002. Output variation from an intensity modulating dynamic collimator.. https://doi.org/10.1118/1.1493782

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Calibration of spectra from dispersive XAS beamlines.

The DXAS Calibration computer program provides a quantitative and automated solution to the problem of calibrating spectra from dispersive XAS beamlines. Such spectra, obtained in arbitrary energy units, are calibrated with respect to the absorption features of a supplied reference spectrum, which has been obtained under similar conditions on a calibrated beamline. In addition to basic energy coordinate transformation parameters, DXAS Calibration supplies instrument corrections to compensate for mismatches in instrument response functions between the dispersive and reference beamlines.

Equipment Failure Analysis↗

Measuring orthopedic implant wear on standard radiographs with a precision in the 10 microm-range.

The aim of this study has been to explore and verify whether the use of a previously designed Analysis-by-Synthesis algorithm is capable to precisely measuring implant wear. The abrasion of polyethylene particles is seen as the main reason for the loosening of prosthetic components in the hip. It lies in the sub-millimeter range, and precision is a crucial point in wear measurement. In the Analysis-by-Synthesis algorithm, the synthetic X-ray image of the implant is matched to its original X-ray projection. This intensity based approach and the use of X-ray images with their inherent high resolution allow principally precise measurements. Wear has been defined based on the estimated implant parameters and under minimization of the impact of the main sources of error. The latter was theoretically studied in a sensitivity analysis. The use of the algorithm was tested in vitro as well as in vivo. In experimental data, the accuracy and the impact of the pelvic position and orientation were studied. The precision was assessed using dual radiographs of 20 patients with total hip replacement. A standard deviation of 49 microm was found.

Equipment Failure Analysis↗

Behavior of metal implants used in ENT surgery in 7 Tesla magnetic resonance imaging.

Magnetic resonance imaging (MRI) has become increasingly important as an imaging technique in cross-sectional imaging of head and neck diseases. To investigate whether MRI examinations can be performed without risk in patients with metal implants even at higher field strengths, we examined different materials in 7 Tesla MRI. Implants near sensory organs like the middle ear or eye are of particular interest here. Using the 7 Tesla research MRI for small animals, we tested implants made of various metals like titanium, gold, gold/platinum, platinum/iridium, gold-plated silver, PTFE and stainless steel for heating, translocation and rotation according to a standardized protocol. A fiber optic temperature probe measured the heating of the implant before, during and after MRI scanning. None of the implants showed significant heating. The gold-plated stainless steel ventilation tube was the only implant to markedly change its position already in the Petri dish. Of the remaining implants, a trachea support ring, a nose dilatator and the wire from the ventilation tubes moved during vibration of the Petri dish. With exception of two implants, all implants changed positions in the water bath. In the swim test, the gold implants showed the least movement of all the implants. In this study, the properties of the non-ferromagnetic implant materials differed in the 7 Tesla MRI. Stainless steel ventilation tubes, the trachea support ring and the nose dilatator were not suited for the 7 Tesla MRI system, because they changed their position during MRI. In the case of ventilation tubes with a steel wire, the wire should be removed before MRI to prevent injury to the external auditory canal. There was a tendency for the pure gold implants to move less in the 7 Tesla MRI than all other tested materials. General statements cannot be made about the MRI suitability of different implants. Every implant should be individually examined to confirm its definitive MRI compatibility. Particularly, middle ear implants warrant special attention here due to their closeness to the oval window.

Equipment Failure Analysis↗