System for robotically assisted percutaneous procedures with computed tomography guidance.

Abstract

We present the prototype of an image-guided robotic system for accurate and consistent placement of percutaneous needles in soft-tissue targets under CT guidance inside the gantry of a CT scanner. The couch-mounted system consists of a seven-degrees-of-freedom passive mounting arm, a remote center-of-motion robot, and a motorized needle-insertion device. Single-image-based coregistration of the robot and image space is achieved by stereotactic localization using a miniature version of the BRW head frame built into the radiolucent needle driver. The surgeon plans and controls the intervention in the scanner room on a desktop computer that receives DICOM images from the scanner. The system does not need calibration, employs pure image-based registration, and does not utilize any vendor-specific hardware or software features. In the open air, where there is no needle-tissue interaction, we systematically achieved an accuracy better than 1 mm in hitting targets at 5-8 cm from the fulcrum point. In the phantom, the orientation accuracy was 0.6 degrees, and the distance between the needle tip and the target was 1.04 mm. Experiments indicated that this robotic system is suitable for a variety of percutaneous clinical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Masamune, G Fichtinger, A Patriciu, R C Susil, R H Taylor, L R Kavoussi, J H Anderson, I Sakuma, T Dohi, D Stoianovici. 2001. System for robotically assisted percutaneous procedures with computed tomography guidance.. https://doi.org/10.1002/igs.10024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.

PURPOSE: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet. MATERIALS AND METHODS: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion. RESULTS: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal. CONCLUSIONS: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.

Biopsy, Needle↗