Needle artifact localization in 3T MR images.

This work explores an image-based approach for localizing needles during MRI-guided interventions, for the purpose of tracking and navigation. Susceptibility artifacts for several needles of varying thickness were imaged, in phantoms, using a 3 tesla MRI system, under a variety of conditions. The relationship between the true needle positions and the locations of artifacts within the images, determined both by manual and automatic segmentation methods, have been quantified and are presented here.

Artifacts↗

Robot-assisted needle placement in open-MRI: system architecture, integration and validation.

This work describes an integrated system for planning and performing percutaneous procedures-such as prostate biopsy-with robotic assistance under MRI-guidance. The physician interacts with a planning interface in order to specify the set of desired needle trajectories, based on anatomical structures and lesions observed in the patient's MR images. All image-space coordinates are automatically computed, and used to position a needle guide by means of an MRI-compatible robotic manipulator, thus avoiding the limitations of the traditional fixed needle template. Direct control of real-time imaging aids visualization of the needle as it is manually inserted through the guide. Results from in-scanner phantom experiments are provided.

Biopsy, Needle↗

System for robotically assisted percutaneous procedures with computed tomography guidance.

We present the prototype of an image-guided robotic system for accurate and consistent placement of percutaneous needles in soft-tissue targets under CT guidance inside the gantry of a CT scanner. The couch-mounted system consists of a seven-degrees-of-freedom passive mounting arm, a remote center-of-motion robot, and a motorized needle-insertion device. Single-image-based coregistration of the robot and image space is achieved by stereotactic localization using a miniature version of the BRW head frame built into the radiolucent needle driver. The surgeon plans and controls the intervention in the scanner room on a desktop computer that receives DICOM images from the scanner. The system does not need calibration, employs pure image-based registration, and does not utilize any vendor-specific hardware or software features. In the open air, where there is no needle-tissue interaction, we systematically achieved an accuracy better than 1 mm in hitting targets at 5-8 cm from the fulcrum point. In the phantom, the orientation accuracy was 0.6 degrees, and the distance between the needle tip and the target was 1.04 mm. Experiments indicated that this robotic system is suitable for a variety of percutaneous clinical applications.

Biopsy, Needle↗