Search PubMed⌕ Search

PubMed · 11844201

Right and left ventricular long-axis function in the fetus using angular M-mode.

Abstract

OBJECTIVE: Long-axis function is determined by the longitudinally oriented myocardial fibers. Postnatally, conventional M-mode is used to assess tricuspid and mitral valve ring movements in relation to the cardiac apex. During fetal life, this is precluded by variable fetal position. We assessed the feasibility of determining right and left ventricular long-axis function in the fetus. METHODS: A prospective, pilot study. The four-chamber view obtained during routine fetal echocardiography was recorded in a cineloop to which B-mode guided M-mode echocardiography was applied using angular M-mode. This allowed retrospective and correct placement of the cursor line from cardiac apex to tricuspid or mitral valve rings. M-mode tracings of the valve ring movements in relation to the apex were derived from the originally stored loop. Data from 18 fetuses (17-29 weeks of gestation) were available for analysis. Total excursion of the valve rings was measured offline. A second cursor line was simultaneously placed in the left ventricular outflow tract during color flow mapping for timing purposes (n = 6). RESULTS: Right and left ventricular long-axis recordings were obtained in 18 and 14 cases, respectively. Total right ventricular excursion was 5.2 mm (SD, 0.9 mm) (range, 3.9-7.2 mm). Total left ventricular free wall excursion was 4.5 mm (SD, 1.1 mm) (range, 3.0-6.8 mm). For paired data, the mean of differences (right ventricle-left ventricle) was 0.8 mm (95% confidence interval 0.5-1.2). The valve rings moved towards the apex during systole (shortening) and away from it during diastole (lengthening). Peak downward movement coincided with cessation of aortic flow and diastolic lengthening with flow through the atrioventricular valves. CONCLUSION: Long-axis function in the fetus is feasible if M-mode angle correction is used. There was no clinically significant difference between tricuspid and mitral valve excursions. The pattern of atrioventricular valve movement is coordinate and similar to that of adults. Long-axis function offers a new avenue to study systolic and diastolic function in the fetus.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J S Carvalho, C O'Sullivan, E A Shinebourne, M Y Henein. 2001. Right and left ventricular long-axis function in the fetus using angular M-mode.. https://doi.org/10.1046/j.0960-7692.2001.00587.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrocardiographic prediction of left ventricular geometric patterns in patients with essential hypertension.

BACKGROUND: The present study sought to determine the diagnostic value of electrocardiographic voltage criteria in predicting geometry patterns in patients with essential hypertension. METHODS: Patients with essential hypertension (n=125) according to left ventricular mass index and relative wall thickness as determined by echocardiography were assigned in the following groups: normal geometry (N, n=50), concentric remodeling (CR, n=12), concentric hypertrophy (CH, n=28) and eccentric hypertrophy (EH, n=35). Each patient underwent 12-lead ECG followed by determination of conventional voltage criteria as well as peak to peak QRS lengths in each lead. RESULTS: Voltage criteria such as Sokolow-Lyon, Cornell, Cornell product >2440, D1R+D3S >25 mm, and AVL R >11 mm could not significantly predict and discriminate geometric patterns of LVH. However, they all were very specific (range 97-100%) and showed very high positive predictive values (range 94-100%) for detecting abnormal geometry. DI peak >12 mm had a sensitivity 61%, specificity 67%, accuracy 63%, positive predictive value 81%, and negative predictive value 42% in predicting to differentiate CH from CR. Sum of the calculated values from the peak of the R to the nadir of the S wave in all limb leads >60 mm had sensitivity 68%, specificity 75%, accuracy 70%, positive predictive value 86% and negative predictive value 50% in predicting to differentiate CH from CR. CONCLUSIONS: Conventional ECG voltage criteria could not significantly discriminate specific geometry patterns observed in patients with essential hypertension.

Echocardiography↗

Echocardiographic evidence of posteromedial hypokinesis of the left ventricle in relation to mitral regurgitation in cardiac sarcoidosis.

We describe herein the case of a 49-year-old female patient with pulmonary sarcoidosis (stage II) with cardiac manifestation. This consisted of systolic dysfunction without dilatation of the left ventricle and severe mitral insufficiency, possibly due to thinning of the posteromedial left ventricular free wall, based on our echocardiographic observations.

Echocardiography↗