Assessment of the intraobserver variability in the measurement of fetal cardiothoracic ratio using ellipse and diameter methods.

OBJECTIVE: To assess the variability of fetal heart and thoracic area and circumference measurements using the ellipse and diameter methods at different gestational ages. DESIGN: This was a prospective cross-sectional study of 200 singleton pregnancies, with no apparent fetal abnormalities. The gestational age ranged between 19 and 42 weeks. At each examination, two transverse frames of the fetal chest at the level of the four-chamber view during diastole were obtained. For each frame, the area and the circumference of the heart and thorax were obtained by the ellipse and diameter methods. In the diameter method, cardiac and thoracic areas and circumferences were derived from the measured anteroposterior and transverse diameters. All measurements were made by the same observer. RESULTS: For the same method, intraobserver variability was good. Coefficient of variation for all measurements varied between 3-11%. The ellipse method tended to give larger measurements than did the diameter method, the absolute difference increasing with fetal age. The mean ellipse/diameter ratio was 1.10, 1.04, 1.05 and 1.02 for heart area, thorax area, heart circumference and thorax circumference, respectively. In most cases, intraobserver variability of the thorax measurements was independent of gestational age. In contrast, there was a greater variability of heart measurements with increasing gestational age. CONCLUSIONS: Both the ellipse and diameter methods of measuring cardiothoracic ratio are clinically useful and fairly reproducible at certain gestations, but are not interchangeable as the ellipse method overestimates measurements compared to the diameter method. The less reproducible measurement of heart size in later gestation should be taken into account when assessing cardiothoracic ratios.

Adult↗

Increased first-trimester fetal nuchal translucency thickness in association with chondroectodermal dysplasia (Ellis-Van Creveld syndrome).

Increased nuchal translucency thickness (NT) is an established sonographic marker of fetal chromosomal abnormality. Several structural fetal defects and genetic syndromes including a range of skeletal dysplasias have been reported in association with increased NT. We report the first case of fetal Ellis-Van Creveld syndrome presenting as raised fetal NT at 13 weeks' gestation. Ultrasonography at 18 weeks' gestation demonstrated a narrow thorax, marked shortening of the long bones with bowed femora and hexadactyly of hands and feet. Pregnancy was terminated at 23 weeks' gestation. The postmortem radiological examination revealed short and bowed long bones with rounded metaphyses, postaxial polydactyly of hands and feet, short ribs and narrow thorax. The acetabular roofs were horizontal with medial and lateral spurs. This case adds a further type of severe skeletal dysplasia to the list of genetic syndromes which may present as increased fetal NT in the late first trimester.

Adult↗

Fetal congenital cardiac diverticulum with pericardial effusion: two cases with different presentations in the first trimester of pregnancy.

Two cases of fetal congenital cardiac diverticula diagnosed at 14 and 12 weeks of gestation are reported. Both presented with a large pericardial effusion. One fetus presented with increased NT which evolved into fetal hydrops. Pericardiocentesis at 16 weeks led to progressive resolution of hydrops. The other showed no hemodynamic compromise, normal nuchal translucency (NT) and spontaneous regression of the effusion. Both children were well at 22 and 17 months of age at the time of writing.

Adult↗

Development of Z-scores for fetal cardiac dimensions from echocardiography.

OBJECTIVES: Z-scores for cardiac dimensions are well established in postnatal life, but have yet to be developed for fetal cardiac dimensions. These would be of real advantage to the clinician in accurately quantifying size and growth of cardiac dimensions and to the researcher by allowing mathematical comparison of growth in differing subgroups of a disease. The purpose of this observational study, conducted at tertiary fetal medicine and cardiology units, was to produce formulae and nomograms allowing computation of Z-scores for fetal cardiac dimensions from knowledge of femur length (FL), biparietal diameter (BPD) or gestational age (GA) using fetal echocardiography. METHODS: Seventeen fetal cardiac dimensions were measured in 130 pregnant women with singleton fetuses of gestational age 15-39 weeks. Regression equations were derived relating all dimensions to FL, BPD and GA. From the calculations, formulae were then developed allowing fetal cardiac Z-score computation. RESULTS: The relationships between cardiac dimensions and FL, BPD or GA were described following natural log transformation. From this analysis, FL (taken as an expression of fetal size) had the highest correlation to fetal cardiac dimensions. From the developed nomograms, Z-scores of specific fetal cardiac structures could be estimated from knowledge of the FL, BPD or GA and echocardiographically derived measurements. CONCLUSIONS: This study allowed computation of Z-scores in fetal life for 17 cardiac dimensions from FL, BPD or GA. Previous studies of normal data allowed qualitative assessment of where abnormal cardiac dimensions lay with regard to the normal range. Z-scores from this study allow quantitative analysis of where such dimensions lie relative to the mean. This permits exact assessment of growth of fetal cardiac structures in normal hearts and particularly in congenitally abnormal hearts where quantitative assessment of the growth of cardiac structures is important in analyzing and planning treatment strategies.

Echocardiography↗

Fetal echocardiography. A sophisticated tool in obstetrics.

Fetal cardiology has been evolving as an exciting speciality over the last 20 years or so. Whilst much is due to technical advances in fetal echocardiographic techniques and the use of sophisticated ultrasound equipment, the partnership among fetal and paediatric cardiologists and a team of professionals working in Fetal Medicine Unit should not be ignored. As a result, targeted fetal echocardiography allows congenital heart disease to be diagnosed in utero with a great degree of accuracy from as early as the end of the first trimester of pregnancy i.e. from around 12 weeks. Conversely, prenatal detection rates in the general population remain suboptimal with many congenital cardiac abnormalities being diagnosed postnatally. A recognised marker for chromosomal abnormalities, that is the finding of an increased nuchal translucency thickness at 11-14 weeks of gestation has also emerged over the last few years as a novel and important marker for major cardiac abnormalities. This has further increased the interest in imaging the fetal heart early in the pregnancy.

Female↗

Clinical impact of first and early second trimester fetal echocardiography on high risk pregnancies.

OBJECTIVE: To evaluate the clinical impact of fetal echocardiography before 16 weeks' gestation on the management of pregnancies with fetuses at risk of congenital heart disease. DESIGN AND SETTING: Observational study in a fetal medicine unit. PARTICIPANTS AND METHODS: 222 consecutive women with high risk pregnancies (230 fetuses) underwent transabdominal fetal echocardiography at a median gestation of 14(+1) weeks. For 10%, transvaginal scans were also performed. Criteria for normal scans were normal sequential segmental analysis, symmetrical four chamber view, normal semilunar valves, arterial outflow tracts, and ductal and aortic arches. Early scans were compared with mid-second trimester fetal echocardiography. Postmortem and postnatal data were added. Adverse pregnancy outcomes were diagnosis of a major cardiac or extracardiac abnormality, chromosomal defects, intrauterine death, or termination of pregnancy. RESULTS: There were 21 abnormal cardiac scans (9%): 14 major structural defects (eight isolated, six with chromosomal or extracardiac abnormalities) in pregnancies resulting in three live births, one intrauterine death, and 10 terminated pregnancies. Seven scans showed asymmetry between right and left sided structures (two isolated, five with chromosomal or extracardiac abnormalities); six of the seven pregnancies were terminated. The scans were normal in 199 cases (87%). Cardiac follow up of 184 of 199 babies (93%) confirmed situs and connections. One case each of pulmonary stenosis and ventricular septal defect requiring postnatal intervention were diagnosed at later scans. In 28 of 199 (14%) babies there was a non-cardiac adverse outcome. First examination was not diagnostic for 10 (4%). CONCLUSION: Early fetal echocardiography in high risk pregnancies was diagnostic in 96%. Abnormal cardiac scans (isolated in 48%, major structural defects in 67%) led to termination of pregnancy in 76%. Most cardiac scans were normal, allowing family reassurance. The high number of adverse outcomes with normal cardiac anatomy stresses the need for a multidisciplinary approach to early fetal echocardiography.

Echocardiography, Doppler, Color↗

The human ductus venosus between 13 and 17 weeks of gestation: histological and morphometric studies.

BACKGROUND: Doppler studies of the ductus venosus are increasingly being integrated in the assessment of fetal well-being. Establishing the precise morphology and structure of the ductus venosus would provide a better understanding of Doppler findings during fetal adaptation. There is conflicting evidence from previous studies about the structure of the ductus venosus, especially with regard to the presence of a sphincter at the ductus venosus inlet. The aim of this study was to examine the morphology and histological structure of the ductus venosus wall and surrounding tissues at 13-17 weeks' gestation. DESIGN: This was a prospective study on 28 fetuses obtained from medical termination of pregnancies between 13 and 17 weeks' gestation. Scanning electron microscopy and histological and immunohistochemical studies were carried out on ductus venosus sections obtained from different spatial planes. RESULTS: The inlet of the ductus venosus contained a shelf which was rich in elastin, but devoid of any evidence of a smooth muscle sphincter. The isthmus of the ductus venosus above the inlet was narrowed, giving the lumen of the vessel an hourglass appearance. The endothelial surface of the ductus venosus, above the level of the inlet, showed longitudinal corrugations along its entire length. Longitudinally arranged elastin fibers were also seen along the length of the ductus venosus. A single layer of longitudinally arranged smooth muscle cells was present along the entire length of the ductus venosus, with occasional individual nerve cells visible in this layer. CONCLUSIONS: The presence of an elastin-rich shelf and a narrow ductus venosus inlet orifice may act to accelerate flow from the portal sinus into a high-velocity system in the ductus venosus. The abundant elastin fibers in the adventitia of the ductus venosus may help antegrade wave propagation by elastic recoil. This study clearly demonstrates the lack of an anatomical smooth muscle sphincter at the ductus venosus inlet. However, the combination of endothelial corrugations and innervated smooth muscle support the hypothesis that the ductus venosus is an actively regulated vessel with the capacity to rapidly change diameter along its entire length in response to certain stimuli.

Endothelium, Vascular↗

Improving the effectiveness of routine prenatal screening for major congenital heart defects.

OBJECTIVE: To evaluate the effectiveness of adding outlet views to the four chamber view in routine prenatal ultrasound screening for major congenital heart defects (CHD) as performed by trained sonographers, and to compare the procedure with current practice. DESIGN AND SETTING: Prospective observational study at a London teaching hospital. PARTICIPANTS AND METHODS: 9277 women booked at a single institution (80% had first trimester nuchal translucency measurement) due to have routine fetal cardiac screening using the four chamber and outflow tract views at > 18 weeks of gestation. MAIN OUTCOME MEASURE: Identification of major CHD in chromosomally normal and abnormal pregnancies antenatally or postnatally. RESULTS: There were 40 abnormalities (4.3/1000), of which 30 were chromosomally normal (3.3/1000). The overall antenatal detection rate was 75% (95% confidence interval (CI) 59% to 87%) and 70% (95% CI 51% to 85%) for euploid pregnancies. Abnormal cardiac views accounted for 70% of all prenatal diagnoses, 30% of which were made at < or = 18 weeks. The sensitivity of cardiac views during the first scan at > 18 weeks was 52%. Of all patients undergoing nuchal translucency screening, 34 had major CHD, nine with increased nuchal translucency (26.5%). Factors influencing the results of this screening programme were training and audit of operators, adequate equipment for antenatal examination, ease of access, and low threshold for referral to specialised fetal echocardiography. CONCLUSION: Adding ventricular outlet views to the four chamber assessment of the heart at routine fetal anomaly scans at > 18 weeks is the most effective technique to detect CHD prenatally. The success of such a programme depends on an infrastructure committed to continuous in house training of obstetric ultrasonographers coupled with feedback from specialised fetal cardiologists, as well as adequate resource allocation to obstetric hospitals involved with antenatal screening.

Adolescent↗

The anatomy of the umbilical, portal and hepatic venous systems in the human fetus at 14-19 weeks of gestation.

BACKGROUND: Ultrasound imaging of the fetal ductus venosus is becoming increasingly commonplace in clinical practice. The true anatomical relationships of the fetal umbilical and portal venous systems have not been clearly defined due to paucity of published data on the relevant anatomy. This has led to confusing terminology when describing the fetal umbilical, portal and hepatic circulations. The aim of the present study was to examine and document the anatomy of the umbilical, portal and hepatic venous systems and to propose a standardized nomenclature. METHODS: This was a prospective study on 11 fetuses obtained from medical termination of pregnancies between 14 and 19 weeks of gestation. The liver was microdissected to expose the branching pattern and anatomical relations of the umbilical, portal and hepatic venous systems. RESULTS: A wide L-shaped venous confluence at the terminal end of the umbilical vein, termed the portal sinus, was identified. The portal sinus was connected to the right and left hepatic lobes, by the right and left intrahepatic portal veins, respectively. The extrahepatic portal vein drained into the portal sinus just before the origin of the right intrahepatic portal vein. The ductus venosus, a branchless straight vessel, originated from the portal sinus and ascended steeply in the direction of the diaphragm. Numerous small vessels draining the liver converged into three main hepatic veins, which open into the subdiaphragmatic vestibulum. CONCLUSION: Based on detailed sequential anatomical dissection and clear illustrations, the present study documents the anatomy of the umbilical, portal and hepatic venous systems. Taking into account the embryological origin of the vessels, a new anatomically appropriate and simplified nomenclature of these venous systems is proposed. In clinical practice, the consistent use of the suggested terminology would allow collection of comparable data between units and enable operators to be confident of which vessels they are sampling by Doppler ultrasound.

Dissection↗

Right and left ventricular long-axis function in the fetus using angular M-mode.

OBJECTIVE: Long-axis function is determined by the longitudinally oriented myocardial fibers. Postnatally, conventional M-mode is used to assess tricuspid and mitral valve ring movements in relation to the cardiac apex. During fetal life, this is precluded by variable fetal position. We assessed the feasibility of determining right and left ventricular long-axis function in the fetus. METHODS: A prospective, pilot study. The four-chamber view obtained during routine fetal echocardiography was recorded in a cineloop to which B-mode guided M-mode echocardiography was applied using angular M-mode. This allowed retrospective and correct placement of the cursor line from cardiac apex to tricuspid or mitral valve rings. M-mode tracings of the valve ring movements in relation to the apex were derived from the originally stored loop. Data from 18 fetuses (17-29 weeks of gestation) were available for analysis. Total excursion of the valve rings was measured offline. A second cursor line was simultaneously placed in the left ventricular outflow tract during color flow mapping for timing purposes (n = 6). RESULTS: Right and left ventricular long-axis recordings were obtained in 18 and 14 cases, respectively. Total right ventricular excursion was 5.2 mm (SD, 0.9 mm) (range, 3.9-7.2 mm). Total left ventricular free wall excursion was 4.5 mm (SD, 1.1 mm) (range, 3.0-6.8 mm). For paired data, the mean of differences (right ventricle-left ventricle) was 0.8 mm (95% confidence interval 0.5-1.2). The valve rings moved towards the apex during systole (shortening) and away from it during diastole (lengthening). Peak downward movement coincided with cessation of aortic flow and diastolic lengthening with flow through the atrioventricular valves. CONCLUSION: Long-axis function in the fetus is feasible if M-mode angle correction is used. There was no clinically significant difference between tricuspid and mitral valve excursions. The pattern of atrioventricular valve movement is coordinate and similar to that of adults. Long-axis function offers a new avenue to study systolic and diastolic function in the fetus.

Echocardiography↗

Congenital absence of portal vein in the fetus: a case report.

Congenital absence of portal vein (CAPV) is a rare abnormality, which may be associated with other abnormalities. We report a case of prenatal diagnosis of absent portal vein confirmed on postnatal ultrasonography and computed tomography scan. The ultrasound features of CAPV include dilated intra-abdominal segment of umbilical vein, dilated inferior vena cava and the presence of hyperechogenic areas in the liver. Blood coming from the umbilical vein directly drains into the inferior vena cava. The dilated intra-abdominal segment of the umbilical vein shows high velocity pulsatile flow, resembling that of ductus venosus. These findings should prompt a careful search for the portal vein and any associated anomalies.

Adult↗

Limitations of using first-trimester nuchal translucency measurement in routine screening for major congenital heart defects.

OBJECTIVE: To evaluate the effectiveness of nuchal translucency (NT) measurement in screening for major congenital heart disease (CHD) in chromosomally normal fetuses. DESIGN: A population based cohort study of all women having fetal NT measurement at 10-14 weeks of gestation in an unselected population over a 3-year period. The outcome measure was the identification of major CHD in chromosomally normal pregnancies either antenatally or postnatally. RESULTS: Major defects of the heart and great arteries were identified in 26 out of 7339 pregnancies (prevalence 3.5 per 1000 pregnancies). Out of 26 cases, only four (sensitivity 15.4%, 95% CI 4-35) were in the group of 258 pregnancies (3.5%) with increased NT of > or = 2.5 mm. The prevalence of major CHD increased from 3.1 per 1000 for NT < 2.5 mm to 50 per 1000 for NT > or = 3.5 mm (likelihood ratio of 14.1, 95% CI 4.2-47.9). The positive and negative predictive values for NT > or = 2.5 mm were 1.6% and 99.7%, respectively. CONCLUSIONS: The prevalence of major CHD in this study was 3.5 per 1000, suggesting that ascertainment of CHD in our study population was thorough. Fetuses with NT measurements > or = 3.5 mm have a significantly increased risk of major CHD, and this identifies a subgroup of high-risk patients in whom early fetal echocardiography would be advocated. The low sensitivity of NT for major CHD in the general population, however, indicates that NT cannot be relied on as the sole or major screening tool for this condition as previously reported.

Adult↗

Prenatal diagnosis of mosaic trisomy 8 in a fetus with normal nuchal translucency thickness and reversed end-diastolic ductus venosus flow.

We report a case of the prenatal diagnosis of trisomy 8 in a fetus presenting with normal nuchal translucency of 0.8 mm and reversed end-diastolic ductus venosus blood flow at a routine first-trimester scan at 11 weeks of gestation. No structural abnormalities were detected by the ultrasound scan. Karyotyping by chorionic villus sampling led to the diagnosis of mosaic trisomy 8, which was confirmed by fluorescent in-situ hybridization on fetal tissue samples.

Adult↗

Significance of chromosome 22q11 analysis after detection of an increased first-trimester nuchal translucency.

OBJECTIVE: To determine the value of performing routine fluorescent in situ hybridization (FISH) for microdeletions of chromosome 22q11 when karyotyping fetuses with increased nuchal translucency. DESIGN: This was a prospective observational study carried out over an 18-month period. Fetal karyotyping by chorionic villus sampling was offered to 5429 women attending for a routine booking scan in the first trimester when their nuchal translucency adjusted risk for Down syndrome was > or = 1 in 300. Cytogenetic samples were routinely tested for the 22q11 microdeletion when the nuchal translucency was > or = 3 mm. RESULTS: The prevalence of increased nuchal translucency > or = 2.5 mm was 180 (3.3%) and > or = 3.5 mm was 42 (0.8%). None of 75 fetuses with an increased nuchal translucency and normal karyotype demonstrated a 22q11 microdeletion on FISH analysis. In the same cohort, 3 of 20 (15%) cases of major congenital heart defects in which nuchal translucency was measured, had a nuchal translucency measurement > or = 2.5 mm. CONCLUSIONS: Routine FISH analysis for chromosome 22q11 microdeletions at the time of chorionic villus sampling for increased first-trimester nuchal translucency is of limited value. As a significant proportion of fetuses with increased nuchal translucency will be found to have congenital heart defects later in the pregnancy, FISH analysis for chromosome 22q11 microdeletions can be targeted to fetuses with specific congenital heart defects. Tissue from the chorionic villus sampling should therefore be stored for subsequent analysis, until after detailed echocardiography is performed.

Adolescent↗