Search PubMed⌕ Search

PubMed · 11827678

New tools for prevention of restenosis could decrease the "oculo-stento" reflex.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael Sturek, Hanumanth K Reddy. 2002-02-01. New tools for prevention of restenosis could decrease the "oculo-stento" reflex.. https://doi.org/10.1016/s0008-6363(01)00567-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound.

This study evaluates the response of the coronary vessel wall to implantation of the sirolimus-eluting stent (SES), Bx-VELOCITY, by using serial intravascular ultrasound. SESs have a major impact on the inhibition of in-stent neointimal hyperplasia. However, changes in the vessel wall and behind stent struts in animal models and humans have not been evaluated after SES implantation. Thirty-four patients who received a SES (n = 24) or a Bx-VELOCITY bare stent (BS) (n = 10) for single de novo coronary lesions and had serial motorized pullback 3-dimensional intravascular ultrasound were included. Stent, lumen, and vessel volumes were similar in the 2 groups at baseline. At follow-up, significantly larger lumen and lower neointimal hyperplasia volumes (0.7 vs 33 mm(3), p = 0.001) were seen in the SES group compared with the BS group. There was no significant difference between SES and BS in either the vessel volume (+2.4% vs +0.7%, p = NS) or the plaque behind stent volume change (+3.4% vs +2.5%, p = NS) from after the procedure to late follow-up. The stent edges also showed no significant difference between postprocedural and follow-up measurements, either in patients receiving SESs or BSs. No stented or edge segment required redilatation in the SES group, whereas 2 patients underwent repeat percutaneous coronary angioplasty in the BS group. In the SES group, 1 patient (4%) showed late acquired incomplete stent apposition. Thus, the SES is effective in inhibiting neointimal hyperplasia without affecting vessel volume and plaque behind the stent.

Angioplasty, Balloon, Coronary↗

Increased cardiac BNP expression associated with myocardial ischemia.

Congestive heart failure is accompanied by increased cardiac brain natriuretic peptide (BNP) gene expression with elevated plasma concentrations of BNP and its precursor, proBNP. We investigated if myocardial ischemia in the absence of overt heart failure may be another mechanism for increased myocardial BNP expression. The BNP expression was examined in hypoxic myocardium of patients undergoing coronary bypass grafting surgery, in patients with coronary artery disease and normal left ventricular function undergoing percutaneous transluminal intervention therapy, and in heart failure patients without coronary artery disease. BNP mRNA was quantified by real-time PCR, and plasma BNP and proBNP concentrations were measured with radioimmunoassays. Quantitative analysis of BNP mRNA in atrial and ventricular biopsies from coronary bypass grafting patients revealed close associations of plasma BNP and proBNP concentrations to ventricular, but not atrial, BNP mRNA levels. Plasma BNP and proBNP concentrations were markedly increased in patients with coronary artery disease but without concomitant left ventricular dysfunction. These results are compatible with the notion that myocardial ischemia, even in the absence of left ventricular dysfunction, augments cardiac BNP gene expression and increases plasma BNP and proBNP concentrations. Thus, elevated BNP and proBNP concentrations do not necessarily reflect heart failure but may also result from cardiac ischemia.

Angioplasty, Balloon, Coronary↗

Is there functional collateral flow during vascular occlusion in angiographically normal coronary arteries?

BACKGROUND: Thus far, it is unknown whether there is functional collateral flow through preexisting anastomoses in patients with angiographically normal coronary arteries. Such preformed coronary collateral vessels could form the basis for subsequently developing protective natural bypasses in the presence of coronary artery disease. METHODS AND RESULTS: Among 100 patients, the collateral flow index (CFI) was measured in coronary arteries without stenotic lesions. The CFI was determined by simultaneous measurement of mean aortic pressure, central venous pressure, and coronary wedge pressure via a sensor-tipped guidewire at the end of a 1-minute balloon occlusion. Patients were divided in 2 groups according to complete angiographic absence (51 patients) or partial presence (49 patients) of stenotic lesions in coronary arteries other than that undergoing collateral measurement. CFI in all patients (61+/-10 years; men/women, 69/31) amounted to 0.18+/-0.08 (range, 0.04 to 0.36). It showed a normal Gaussian frequency distribution; 22 individuals had a CFI > or =0.25, a value that was empirically found to represent well-developed collaterals protective against myocardial ischemia during coronary occlusion. Accordingly, 17 patients did not reveal signs of myocardial ischemia during coronary balloon occlusion, as assessed from an intracoronary ECG, and 26 patients did not experience angina pectoris during occlusion. CONCLUSIONS: In humans with angiographically normal coronary arteries, there are functional collateral vessels to the extent that one fifth to one quarter of them do not show signs of myocardial ischemia during brief vascular occlusions.

Angioplasty, Balloon, Coronary↗