Search PubMed⌕ Search

PubMed · 11791558

Flow-based microimmunoassay.

Abstract

A small-volume heterogeneous immunoassay system is demonstrated in microchannels exploiting magnetic manipulations of small paramagnetic particles (1-2-microm diameter). The small-diameter particles help to create a high surface-area-to-volume ratio that generates the sensitivity for the small detection volumes. Flow characteristics of the magnetically formed packed bed within the channel allow the assay to be carried out quickly (minutes) while passing appropriate volumes of both samples and reagents (microliters to hundreds of nanoliters) through the system. The assay is demonstrated with a direct interaction of fluorescein isothiocyanate (FITC) with an immobilized anti-FITC conjugate in which a small-volume sample (< 1 microL) reaches 90% of maximum signal in 3 min. Heterogeneous sandwich assays are demonstrated with parathyroid hormone (PTH) and interleukin-5 (IL-5). Both the PTH assay and IL-5 assays were carried out on microliter volumes and demonstrated physiologically relevant sensitivity (approximately microg/L).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M A Hayes, T N Polson, A N Phayre, A A Garcia. 2001-12-15. Flow-based microimmunoassay.. https://doi.org/10.1021/ac0104680

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification of isoflavones in red clover by high-performance liquid chromatography.

An RP-HPLC method for the determination of daidzein, genistein, formononetin and biochanin A in red clover (Trifolium pratense L.) was developed and validated. The compounds are quantified after hydrolytic extraction using an internal standard. On a base-deactivated C(18) column good separation of the analytes, also from accompanying substances, and excellent peak shape are achieved by gradient elution with aqueous sulfuric acid and acetonitrile. The method was applied to the analysis of different red clover cultivars.

Calibration↗

Concept of sequential analysis of free and conjugated phytosterols in different plant matrices.

A unique concept and method for the determination of the total plant sterol content as sum of free sterols (FS), steryl esters (SE), steryl glycosides (SG) and acylated steryl glycosides (ASG) in different plant materials (pumpkin seeds, lecithins) and phytopharmaceuticals derived thereof, was developed. For this purpose, a multidimensional sample clean-up protocol based on efficient solid-phase extraction materials was elaborated and the SG were isolated employing a novel phenyl boronic acid modified silica gel material. Along this line also a set of steryl glucosides was synthesised and employed as internal standard and for calibration in the course of quantitative analysis. Final quantification of SG was carried out with reversed-phase HPLC in combination with evaporative light scattering detection (ELSD); the ASG were determined after conversion to SG by mild alkaline hydrolysis. In order to determine the total plant sterol profile the sum of FS and SE was additionally analysed from the unsaponifiable lipid fraction by GC-FID. The yields obtained from recovery tests for the determination of SG using soya lecithin as matrix to which 2, 20 and 40 mg/g of cholesterol-beta-D-glucoside was added were 99.10, 98.07 and 90.00%, and the RSDs were 4.11, 2.62 and 4.50%, respectively. Application related to the qualitative and quantitative analysis of total phytosterol profiles in different plant matrices and extracts demonstrate the validity of the method.

Calibration↗

De novo prediction of three-dimensional structures for major protein families.

We use the Rosetta de novo structure prediction method to produce three-dimensional structure models for all Pfam-A sequence families with average length under 150 residues and no link to any protein of known structure. To estimate the reliability of the predictions, the method was calibrated on 131 proteins of known structure. For approximately 60% of the proteins one of the top five models was correctly predicted for 50 or more residues, and for approximately 35%, the correct SCOP superfamily was identified in a structure-based search of the Protein Data Bank using one of the models. This performance is consistent with results from the fourth critical assessment of structure prediction (CASP4). Correct and incorrect predictions could be partially distinguished using a confidence function based on a combination of simulation convergence, protein length and the similarity of a given structure prediction to known protein structures. While the limited accuracy and reliability of the method precludes definitive conclusions, the Pfam models provide the only tertiary structure information available for the 12% of publicly available sequences represented by these large protein families.

Calibration↗