Search PubMed⌕ Search

PubMed · 11740455

[Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels].

Abstract

PURPOSE: The absorbed dose during clinical examinations of the head, thorax, abdomen and pelvis performed with a single-slice CT scanner and a new multi-slice CT system was measured and compared. Technical parameters, defined at installation and memorized on the two CT machines relate to a standard-sized patient and were considered the reference standard. Our experimental data were also been compared with the Diagnostic Reference Levels (D.L. 26/5/2000 n.187, Annex V). MATERIAL AND METHODS: We compared the performance of a multi-slice GE LightSpeed QX/i ADVANTAGE to that of a single-slice GE ProSpeed SX. The radiation beam profiles were measured at isocenter using a phosphor plate. Dose measurements were performed, according to the EUR 16262 EN Guidelines, with a 10-cm long CT pencil ionisation chamber and two PMMA phantoms (CEI EN 61223-2-6) for head and body respectively. RESULTS: The obtained (normalised and weighted) computed tomographic dose index (nCTDIW) values were systematically higher for the multi-slice system (up to 36%) and the dose-length product (DLP) values on the multi-slice scanner exceeded the equivalent single-slice DLP values. The values were, however, always lower than DRLs, except in the case of the head multi-slice protocol, the technical parameters of which need to be improved. Our results allowed moreover to calibrate the automatic dose evaluation system of the multi-slice system, which systematically underestimated DLP values. DISCUSSION AND CONCLUSIONS: The comparison showed that the multi-slice scanner delivers a higher dose compared to the single-slice scanner. This is due to the radiation beam profile which is wider than the total active detector width, to the shorter focal spot-to-isocenter distance and to the effective scan length, which is longer than the nominal irradiated volume because the reconstruction algorithm of a multi-slice helical CT image requires the projection data from all detector rows. Nevertheless, the technology of new CT systems equipped with a multiple row detectors array can improve the protection of the patient thanks to very short irradiation time (less than 1 s) and reduced current values. In order to optimize the dose to the patient some acquisition parameters have been adjusted for head examinations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Moro, A Bolsi, M Baldi, G Bertoli, D Fantinato. 2001. [Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels].. https://pubmed.ncbi.nlm.nih.gov/11740455/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Soil-to-grain transfer of fallout 90Sr for 28 winter wheat cultivars.

In order to identify wheat cultivars with minimum soil-to-grain transfer of fallout 90Sr, 28 winter wheat cultivars were investigated at three different sites with different soil types in Upper Bavaria. Each cultivar was grown on an area of 10 m2 and harvested in August 1999. Mean soil-to-grain concentration ratios (C(r)) were 0.151 +/- 0.029, 0.205 +/- 0.035 and 0.060 +/- 0.012, respectively. The C(r) values obtained varied by factors of up to 2.6 for the different cultivars at a given site, and by factors of up to 5.0 for the different sites and a given cultivar. Site-averaged normalized concentration ratios (SANC(r)) ranged from 0.666 +/- 0.062 to 1.503 +/- 0.161. The cultivars Convent, Ludwig, and Semper, showed the lowest uptake of (90)Sr compared to the mean of all cultivars at each site. A cultivar that shows both minimum uptake of 90Sr and 137Cs could not be identified. The results suggest that 90Sr rather than 137Cs might be the limiting radionuclide concerning the use of contaminated land for wheat production. Thus, more efforts might be necessary identifying wheat cultivars with minimum 90Sr uptake.

Radiation Dosage↗

Etched tracks and serendipitous dosimetry.

Nuclear tracks in detectors that just happened to be there can be found in unexpected places. Eyeglasses, household glass, minerals, objects that were exposed to nuclear explosions, and space equipment on the moon are examples. Such materials allow us to measure doses of past radon exposures, cosmic-ray fluences, fission rates and neutrons. Incidental results include measuring mountain-building rates and deciding where finding oil is likely (or unlikely); in another case erosion rates of surface materials in space are found. New results that assess the effects of hydration layers on the leaching out from glass surfaces of imbedded alpha-recoil nuclei imply that long-term, retrospective radon measurements can be made more reliable by selecting only glass with compact hydration layers.

Radiation Dosage↗