Search PubMed⌕ Search

PubMed · 11702892

Third ventriculostomy.

Abstract

Since its description by Dandy in 1922, several techniques have been used to perform third ventriculostomy under endoscopic control. Except for the blunt technique, in which the endoscope is used by itself to create the opening in the floor of the third ventricle, the other techniques require more than one instrument to perforate the floor of the ventricle and enlarge the ventriculostomy. The new device described is a sterilizable modified forceps that allows both the opening of the floor and the enlargement of the ventriculostomy in a simple and effective way. The new device has the following characteristics: 1) the tip of the forceps is thin enough to allow the easy perforation of the floor of the ventricle; 2) the inner surface of the jaws is smooth to avoid catching vessels of the basal cistern; and 3) the outer surface of the jaws has indentations that catch the edges of the opening to prevent them from slipping along the instrument's jaws. The ventricle floor is opened by gentle pressure of the forceps, which is slowly opened so that the edges of the aperture are caught by the distal outer indentation of the jaws, leading to an approximately 4-mm opening of the floor. This device has been used successfully in 10 consecutive patients. This new device allows surgeons to perform third ventriculostomy under endoscopic control in a very simple, quick, and effective way, avoiding the need for additional single-use instruments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W P Vandertop, A van der Zwan, R M Verdaasdonk. 2001. Third ventriculostomy.. https://doi.org/10.3171/jns.2001.95.5.0919

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗