Search PubMed⌕ Search

PubMed · 11543549

Fourier-transform optical microsystems.

Abstract

The design, fabrication, and initial characterization of a miniature single-pass Fourier-transform spectrometer (FTS) that has an optical bench that measures 1 cm x 5 cm x 10 cm is presented. The FTS is predicated on the classic Michelson interferometer design with a moving mirror. Precision translation of the mirror is accomplished by microfabrication of dovetailed bearing surfaces along single-crystal planes in silicon. Although it is miniaturized, the FTS maintains a relatively high spectral resolution, 0.1 cm-1, with adequate optical throughput.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S D Collins, R L Smith, C Gonzalez, K P Stewart, J G Hagopian, J M Sirota. 1999-06-15. Fourier-transform optical microsystems.. https://doi.org/10.1364/ol.24.000844

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prototype results of a phase-shifting interferometer capable of measuring the complex index and profile of a test surface.

Results are presented from a prototype phase-shifting interferometer capable of measuring both the real and the imaginary part of the complex index of refraction and the surface profile of a test surface. The three parameters of interest are extracted from the measured data by maximum-likelihood estimation theory. The performance of the system is quantitatively assessed with Cramer-Rao lower bounds. The results are shown to be strongly dependent on the quantization of the interferograms from the 8-bit CCD camera, the incident electric field amplitude, and the relative amplitude and phase difference of each polarized component through each arm of the interferometer.

Equipment Design↗

Mixing processes in a zigzag microchannel: finite element simulations and optical study.

A finite element model has been used in order to study the mixing process of species in a 100-microm-wide zigzag microchannel integrating a "Y" inlet junction. The distribution of the concentration was obtained by solving successively the Navier-Stokes equation and the diffusion-convection equation in the steady state form. Because of the large range of Reynolds numbers studied (1 < Re < 800), the 2D diffusion-convection simulations are carried out with high diffusion coefficients. The results illustrated the effects of both flow rate and channel geometry on hydrodynamics and mixing efficiency. Below a critical Reynolds number of approximately 80, the mixing is entirely ensured by molecular diffusion. For higher Reynolds numbers, simulations revealed the mixing contribution of laminar flow recirculations. This effect increases for lower values of diffusion coefficients. Experimental studies on the mixing of species at different flow rates are reported showing the same hydrodynamic tendency.

Equipment Design↗