Search PubMed⌕ Search

PubMed · 11542827

The Protein Crystallization Facility (PCF) for EURECA.

Abstract

Research on the structure of molecules by X-ray diffraction analysis requires large single crystals. However, the dynamic behavior of proteins caused by their high molecular weight prevents the growth of large single crystals if this process is disturbed by thermal convection. For example, protein single crystals grown under terrestrial (1 g) conditions are limited to dimensions in the order of 0.1 mm, whereas the size of crystals, grown under (quasi) space conditions has been 5 times larger (pilot experiment CRYOSTAT, Spacelab). Under EURECA conditions (e.g. no microgravity disturbances), the result in regularity of crystal growth and size is expected to be much better. In this paper an overview is given of the protein crystallization facility which includes Experiment-, Service- and Secondary Cooling Module, and its interfaces to the EURECA Carrier. At the end, there will be presented a short mission profile concerning cooling-, power- and data exchange requirements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Schoen, F Seifert. The Protein Crystallization Facility (PCF) for EURECA.. https://doi.org/10.1016/0094-5765(88)90003-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A correlation to estimate the velocity of convective currents in boilover.

The mathematical model proposed by Kozanoglu et al. [B. Kozanoglu, F. Ferrero, M. Muñoz, J. Arnaldos, J. Casal, Velocity of the convective currents in boilover, Chem. Eng. Sci. 61 (8) (2006) 2550-2556] for simulating heat transfer in hydrocarbon mixtures in the process that leads to boilover requires the initial value of the convective current's velocity through the fuel layer as an adjustable parameter. Here, a correlation for predicting this parameter based on the properties of the fuel (average ebullition temperature) and the initial thickness of the fuel layer is proposed.

Convection↗

Modelling the leaching of imazapyr in a railway embankment.

The use of herbicides on railway tracks is known to present a risk to groundwater, but little is known of the mechanisms influencing leaching through the coarse material used to construct railway embankments. Therefore, in the present study, four different models based on the convection-dispersion equation (CDE) were compared with previously reported field data on the leaching of imazapyr. In particular, the significance of non-equilibrium processes was investigated by comparing different CDE formulations accounting for preferential finger flow, particle-facilitated transport and kinetic sorption. The traditional CDE assuming 'local equilibrium' based on 24 h batch sorption data gave poor results (model efficiency - 1.1). It strongly underestimated leaching of imazapyr in the first 4 months following application, thus confirming the importance of non-equilibrium transport processes. Accounting for short-term sorption kinetics made little difference, giving similar results to the 'local equilibrium' CDE simulation. A simulation accounting for particle-facilitated transport could accurately match this accelerated transport, and also gave the best overall fit to the data (model efficiency 0.76). However, not even this model could match the long-term retention of imazapyr residues observed close to the soil surface more than 1 year after application, and it also underestimated the time of breakthrough to groundwater. This strongly suggests that a long-term retention/sorption process not included in any of the models tested (i.e. sorption hysteresis or bound residues) acted to retard leaching. The formation of 'protected' residues was also indicated by a much slower degradation of imazapyr more than 1 year after application. Industry.

Convection↗

Foliage influences forced convection heat transfer in conifer branches and buds.

Conifer foliage structures affect branch and bud temperature by altering the development and convective resistance of the thermal boundary layer. This paper examines foliage effects on forced convection in branches and buds of Picea glauca (Moench) Voss and Pinus contorta Dougl. Ex. Loud., two species that represent the range of variation in foliage structure among conifers. Forced convection is characterized by a power law relating Nusselt (heat transfer) and Reynolds (boundary layer development) numbers. Data were collected in a laminar flow wind tunnel for free stream velocities of 0.16-6.95 m s(-1). Scaling parameters were compared against literature values for silver cast branch replicas, a bed of real foliage, cylinders, and tube banks. Foliage structures reduced Nusselt numbers (heat transfer) relative to cylinders, which are typically used to approximate leafless branches and buds. Significantly different scaling relationships were observed for all foliage structures considered. Forced convection scaling relationships varied with foliage structure. The scaling relationships reported here account for variation within populations of branches and buds and can be used to characterize forced convection in a forest canopy.

Convection↗