Search PubMed⌕ Search

PubMed · 11508962

Optimal focusing by spatio-temporal inverse filter. I. Basic principles.

Abstract

A focusing technique based on the inversion of the propagation operator relating an array of transducers to a set of control points inside a medium was proposed in previous work [Tanter et al., J. Acoust. Soc. Am. 108, 223-234 (2000)] and is extended here to the time domain. As the inversion of the propagation operator is achieved both in space and time, this technique allows calculation of the set of temporal signals to be emitted by each element of the array in order to optimally focus on a chosen control point. This broadband inversion process takes advantage of the singular-value decomposition of the propagation operator in the Fourier domain. The physical meaning of this decomposition is explained in a homogeneous medium. In particular, a definition of the number of degrees of freedom necessary to define the acoustic field generated by an array of limited aperture in a focal plane of limited extent is given. This number corresponds to the number of independent signals that can be created in the focal area both in space and time. In this paper, this broadband inverse-focusing technique is compared in homogeneous media with the classical focusing achieved by simple geometrical considerations but also with time-reversal focusing. It is shown that, even in a simple medium, slight differences appear between these three focusing strategies. In the companion paper [Aubry et al., J. Acoust. Soc. Am. 110, 48-58 (2001)] the three focusing techniques are compared in heterogeneous, absorbing, or complex media where classical focusing is strongly degraded. The strong improvement achieved by the spatio-temporal inverse-filter technique emphasizes the great potential of multiple-channel systems having the ability to apply completely different signal waveforms on each transducer of the array. The application of this focusing technique could be of great interest in various ultrasonic fields such as medical imaging, nondestructive testing, and underwater acoustics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Tanter, J F Aubry, J Gerber, J L Thomas, M Fink. 2001. Optimal focusing by spatio-temporal inverse filter. I. Basic principles.. https://doi.org/10.1121/1.1377051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thymus involution and cerebral white matter damage in extremely low gestational age neonates.

BACKGROUND: Among newborns who die, those who have cerebral white matter damage are more likely than others to have thymus involution and low thymus weights. OBJECTIVE: We sought to evaluate in a population of preterm newborns who did not die if those who developed a cerebral white matter damage (as defined by an echolucency) are more likely than others to have thymus involution as assessed on chest radiographs. METHOD: The 89 infants whose data were evaluated were born before the 28th week of gestation, had at least one chest radiograph within the first 2 days of life (to determine thymus size), and at least one cranial ultrasonogram to assess for white matter echolucency. RESULTS: Eighty-five percent of these infants had a small thymus within the first 2 weeks of life. Median time to thymus involution in those born before the 26th week of gestation was 36 h, and in those born during or after the 26th week of gestation was 140 h. Infants who developed involution before the median time in their respective gestational age groups were classified as early involuters (group 1) and were compared to their peers with late/no involution (group 2). Infants with an echolucency were more likely to have had early involution than infants without an echolucency (89% vs. 44%) (p = 0.01). This relationship was not distorted by potential confounders. The echolucency odds ratio associated with early thymus involution was consistently above 8 in all strata of the sample. CONCLUSION: These results are consistent with the possibility that early thymus involution and neonatal white matter damage are not independent phenomena and may have common antecedents.

Echoencephalography↗