Search PubMed⌕ Search

PubMed · 11476241

Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays.

Abstract

This article presents the first example of a microfluidic chip for heterogeneous bioassays using a locally immobilized biospecific layer and operated electrokinetically. The reaction chamber has picoliter dimensions and is integrated into a network of microchannels etched in glass. The high affinity of protein A (PA) for rabbit immunoglobulin G (rIgG) was exploited for chip testing, with PA being immobilized on microchannel walls and fluorescently labeled (Cy5) rIgG serving as sample. It was possible to operate the chip in an immunoaffinity chromatographic manner, using electrokinetically pumped solutions. Concentration of antibody from dilute solution onto the solid phase was demonstrated, with signal gains of approximately 30 possible. A dose-response curve for Cy5-rIgG was obtained for concentrations down to 50 nM, for an incubation time of 200 s. The flexibility of chip layout was demonstrated for competitive immunoassay of rIgG, using both a combined sample/tracer incubation and sequential addition of these solutions. With assay times generally below 5 min for this unoptimized device, the microfluidic approach described shows great potential for many high-throughput screening applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Dodge, K Fluri, E Verpoorte, N F de Rooij. 2001-07-15. Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays.. https://doi.org/10.1021/ac0015366

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real-time quantification of RNA polymerase activity using a "broken beacon".

A novel assay using a hybridization-based method was developed for real-time monitoring of RNA synthesis. In this work, a "broken beacon" in which the fluor and quencher were located on separate but complementary oligonucleotides was used to quantify the amount of RNA production by T7 polymerase. The relative lengths of the fluor-oligo and quencher-oligo, and their relative concentrations were optimized. The experimentally determined limit-of-detection was approximately 45 nM. The new assay was compared to the "gold-standard" radiolabel ([(32)P]NTP incorporation) assay for RNA quantification. While the broken beacon assay exhibited a higher limit of detection, it provided an accurate measure of RNA production rates. However, the broken beacon assay provided the significant analytical advantages of (i) a real-time and continuous measurement, (ii) no requirement for the use of radiolabels or gel-based analysis, and (iii) substantial time and labor savings.

Carbocyanines↗

Characterization of DNA hybridization on partially aminated diamond by aromatic compounds.

Here, we report a novel method of micropatterning oligonucleotides via aromatic groups as linkers on partially amino-terminated diamond and the inherence on subsequent hybridization. The covalent immobilization of probe oligonucleotides and characterization of immobilized probe oligonucleotides with carboxylic compounds were investigated by X-ray photoelectron spectroscopy (XPS). To confirm the effects of linker flexibility in a low amino group on diamond for probe oligonucleotides, three kinds of dicarboxylic compound--adipic acid, terephthalic acid, and trimesic acid--were used for immobilization of probe oligonucleotides, like linkers; and these oligonucleotides were hybridized with target oligonucleotides labeled with Cy 5 on the micropatterned diamond surface. The hybridization intensities determined by epifluorescence microscopy were compared and analyzed.

Carbocyanines↗