Abstract

Pulsatile release implants were developed that release substances up to 58 days post implantation. With a cylindrical size of 2 mm diameter and 1.8 mm height the matrices can carry as much as 1 mg of drug and allow even for intracranial implantation into a rodent model. The matrices are made of materials that have been used for parenteral applications in humans before such as surface eroding polyanhydrides and bulk eroding poly(D,L-lactic acid) or poly(D,L-lactic acid-co-glycolic acid). The onset of drug release is controlled by the degradation of bulk eroding polymers which are known to exhibit a certain stability over a defined period of time and which start eroding after they reach a critical degree of degradation. The time of drug release onset was found to depend on the molecular weight and the chemical state of the carboxylic acid end of the polymer chain. For testing the onset of release in vivo a nude mouse model was developed where the release of Evan's blue could be observed visually after subcutaneous application. By combining individual matrices with different release onset, a therapeutic system can be composed that releases drugs after implantation at predetermined time points in a preprogrammed way. Potential applications for such matrices is vaccination and local tumor therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Vogelhuber, P Rotunno, E Magni, A Gazzaniga, T Spruss, G Bernhardt, A Buschauer, A Göpferich. 2001-05-18. Programmable biodegradable implants.. https://doi.org/10.1016/s0168-3659(01)00282-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Synthesis, degradation, and in vitro cell responses of sodium phosphate glasses for craniofacial bone repair.

This report outlines the initial synthesis, degradation, and short-term biocompatibility of sodium phosphate glasses, for use in the drawing of fibers and manufacture of biodegradable composites. Biocompatibility studies were performed using a macrophage cell line and primary human craniofacial osteoblasts. Sodium hydrogen phosphate and sodium dihydrogen phosphate glass synthesized for less than 1 h, resulted in a higher degradation rate than glass synthesized for 3 h or more (0.015 mg cm(-2) h(-1)). Glasses with high and low ratios of hydrogen phosphate to dihydrogen phosphate had very similar degradation rates. A condensation route for the formation of the glass should give rise to varying degradation rates with varying ratios of starting materials. It is suggested that the degradation rate of the glass is independent of the concentrations of the initial reagents and that ring-opening polymerization, which reaches an equilibrium state, occurs. Biocompatibility studies suggest minimal macrophage activation (low levels of peroxide and interleukin-1beta release and rounded morphology) and high osteoblast biocompatibility. The ultimate aim of our studies is to produce a biocompatible soluble phosphate glass that can be drawn into fibers for incorporation into a polycaprolactone matrix for craniofacial bone repair. This report demonstrates the successful production of a soluble glass, which is biocompatible with regard to osteoblasts and macrophages. Recent data from our laboratory have demonstrated successful fiber drawing and production of a novel polycaprolactone.

Absorbable Implants↗

Adsorption and release properties of growth factors from biodegradable implants.

The present investigation was performed to study the adsorption behavior of growth factors and their release characteristics from biodegradable implants in an in vitro study. We investigated the stability of growth factors administered on various scaffolds. We used porous tricalcium phosphate ceramics (alpha-TCP), a neutralized glass-ceramics (GB9N), a composite (polylactid/-glycolid/GB9N), and solvent dehydrated human bone as carriers. Block shaped scaffolds (sized: 7 x 7 x 10 mm) were loaded with 5 microg of either bone morphogenetic protein (rxBMP-4), basic fibroblast growth factor (rh-bFGF), or vascular endothelial growth factor (rh-VEGF) solved in 150 microL PBS. The growth factors were labeled with Iodine125 (I-125) for detecting the adsorbed and released amount of growth factors by counting the samples for total I-125 activity. We observed that the adsorption of these growth factors seems to depend on two different parameters: first on the nature of the tested material, and second on the growth factors on their own. The release kinetics of the growth factors from the biodegradable implants can be described as a two phase process-a very rapid release during the first hours by an elution of not adsorbed protein, followed by a specific release, which depends upon the chemical/physical interaction of the material and the growth factor used. Analyzing the eluted proteins on SDS-PAGEs rh-VEGF was degraded into a smaller fragment with a size of around 15 kDa, while rxBMP-4 and rh-bFGF showed a complete degradation into fragments smaller than 3 kDa after more than 3 days. Although this in vitro study suggests that biodegradable implants might be successfully used as carriers for osteogenic growth factors, the different release kinetics as well as the alteration of their molecular structure including loss of biological activity should be considered.

Absorbable Implants↗

Fabrication of poly(alpha-hydroxy acid) foam scaffolds using multiple solvent systems.

The present studies describe the fabrication and characterization of highly porous and interconnected poly(alpha-hydroxy acid) foam scaffolds produced using a phase separation multisolvent system, followed by a sublimation process. Fabrication parameters, including solvent composition, polymer concentration, freezing temperature, polymer type, and polymer molecular weight, were optimized to produce the desired foam microstructure. Analyses of selected samples with scanning electron microscopic images and mercury intrusion porosimetry indicated polymer foams with pore size ranges of 100-350 microm, a porosity >90%, and an interconnecting open-pore foam structure. Scaffold degradation profiles varied according to the type and molecular weight of the polymers. Cytocompatibility assays demonstrated that the preferred foam structures were nontoxic and osteoprecursor cells seeded into the scaffolds exhibited the ability to attach, propagate, and differentiate into a calcified structure.

Absorbable Implants↗