Search PubMed⌕ Search

Biomedical subjects

W Vogelhuber

Publications and source records attributed to W Vogelhuber.

2 recordsLinked to original sources

Efficacy of BCNU and paclitaxel loaded subcutaneous implants in the interstitial chemotherapy of U-87 MG human glioblastoma xenografts.

Nude mice were challenged with human U-87 MG glioblastoma tumors to assess the efficacy of different cytostatics and different application protocols. While the intraperitoneal application of BCNU solutions (3 times 20 mg BCNU/kg) had no effect on tumor growth, the application of polymer matrices made of a physical mixture of poly(1,3-bis[carboxyphenoxpropane]-co-sebacic acid) 20:80 with poly(D,L-lactic-co-glycolic acid) loaded with 0.25 mg BCNU, slowed down the growth of tumors significantly. When the animals were treated with implants carrying 0.25 mg BCNU they responded to the treatment whether the tumor had been inoculated recently (9 days ago) or whether it was fully established (after 20 days). After its sensitivity was proven, the xenograft model was used to further investigate the efficacy of anticancer drugs and some treatment regimens using polymer implants. Thus the tumor model allowed to discriminate between the efficacy of different doses of BCNU. Only implants loaded with 0.75 or 1 mg of BCNU led to a substantial suppression of tumor growth over approximately 2 months. While BCNU was only able to suppress the growth of the tumor, the combination of BCNU with paclitaxel led to a complete remission in some animals. These preliminary results suggest that combinations of cytostatics might improve local chemotherapy of malignant glioma substantially. Based on our data it will be worthwhile to investigate implants that release drugs such as BCNU and paclitaxel closer. Amongst other factors we will try to elucidate the effect of repetitive doses of drugs using programmable implants.

Animals↗

Programmable biodegradable implants.

Pulsatile release implants were developed that release substances up to 58 days post implantation. With a cylindrical size of 2 mm diameter and 1.8 mm height the matrices can carry as much as 1 mg of drug and allow even for intracranial implantation into a rodent model. The matrices are made of materials that have been used for parenteral applications in humans before such as surface eroding polyanhydrides and bulk eroding poly(D,L-lactic acid) or poly(D,L-lactic acid-co-glycolic acid). The onset of drug release is controlled by the degradation of bulk eroding polymers which are known to exhibit a certain stability over a defined period of time and which start eroding after they reach a critical degree of degradation. The time of drug release onset was found to depend on the molecular weight and the chemical state of the carboxylic acid end of the polymer chain. For testing the onset of release in vivo a nude mouse model was developed where the release of Evan's blue could be observed visually after subcutaneous application. By combining individual matrices with different release onset, a therapeutic system can be composed that releases drugs after implantation at predetermined time points in a preprogrammed way. Potential applications for such matrices is vaccination and local tumor therapy.

Absorbable Implants↗