[Optimizing dosage in thoracic computerized tomography].

Abstract

Radiation exposure in computed tomography (CT) by far exceeds radiation dose in chest radiography. Dose requirements in CT of the chest, however, are much smaller than for the abdomen because of low x-ray absorption in the lungs. This article describes scanner parameters that influence patient exposure and image quality. Suitable compromises will be explained that allow for dose reduction in chest CT without jeopardising image quality. Dose reduction in chest CT should be performed depending on the clinical indication and requires active reduction of mAs settings. For helical CT, a pitch of 1.5 to 2 should be employed. Dedicated low-dose techniques for screening of bronchogenic carcinoma are described. Dose reduction decreases image quality but the detrimental effects can be reduced by applying proper parameters for scanning and image reconstruction. Thus, images of the mediastinum should be reconstructed with a smoothing filter, while a higher resolution filter should be used for the lungs. In multislice CT, reconstruction of thicker axial or multiplanar sections retains spatial resolution but keeps image noise and thus dose requirements low. The effective, weighted CT dose index (CTDIw,eff) can serve as a rough estimate of the effective patient dose (E) in helical or multislice CT of the whole chest: for most scanners and age groups the conversion factors are 0.5 mSv/mGy for females and 0.4 mSv/mGy for males.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Prokop. 2001. [Optimizing dosage in thoracic computerized tomography].. https://doi.org/10.1007/s001170050987

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗