Search PubMed⌕ Search

Biomedical subjects

M Prokop

Publications and source records attributed to M Prokop.

At least 19 recordsLinked to original sources

Dynamic cine-CT angiography for the evaluation of the thoracic aorta; insight in dynamic changes with implications for thoracic endograft treatment.

OBJECTIVE: Thoracic aneurysm preoperative imaging is performed using static techniques without consideration of normal aortic dynamics. Improved understanding of the native aortic environment into which thoracic endografts are placed may aid in device selection. It is unclear what comprises normal thoracic aortic pulsatility. We studied these phenomena dynamically using ECG-gated 64-slice CTA. METHODS: Maximum diameter and area change per cardiac cycle was measured at surgically relevant anatomic thoracic landmarks in ten patients; 1.0 cm proximal and distal to the subclavian artery, 3.0 cm distal to the subclavian artery, and 3.0 cm proximal to the celiac trunk. Data was acquired using a novel ECG-gated dynamic 64-slice CT scanner during a single breath hold with a standard radiation dose and contrast load. Eight gated data sets, covering the cardiac cycle were reconstructed, perpendicular to the central lumen. RESULTS: There is impressive change in both maximum diameter and area in the thoracic aorta during the cardiac cycle. Mean maximum diameter changes of greater than 10% are observed in the typical sealing zones of commercially available endografts corresponding to diameter increases of up to 5mm. Aortic area increases by over 5% per cardiac cycle. CONCLUSIONS: ECG-gated dynamic CTA with standard radiation dose is feasible on a 64-slice scanner and provides insight into (patho) physiology of thoracic aortic conformational changes. Clinicians typically oversize thoracic endografts by 10%. With aortic pulsatility resulting in diameter changes of up to 17.8%, the potential exists for endograft undersizing, graft migration, intermittent type I endoleak, and poor patient outcome. Furthermore, aortic pulsatility is not evenly distributed, and non-circular stentgraft designs should be considered in the future since aortic distension in the aneurysm neck is not evenly distributed.

Angioplasty↗

[5 years of "concerted action dose reduction in CT" -- what has been achieved and what remains to be done?].

In May 1998, the German "Concerted Action Dose Reduction in CT" was founded by all parties involved in CT. Its intention was to achieve a significant reduction of the radiation exposure caused by CT, a matter that has increasingly been considered a major challenge since the early nineties. As a result of a number of joint efforts, the essential preconditions have been established by now. The fifth anniversary of the Concerted Action gave rise for both retrospection and outlook on the tasks that have already been accomplished and those that still need to be done. For this purpose, a one-day symposium took place in Berlin on November 4, 2003. The contents of a total of 18 contributions will be outlined here in brief.

Adult↗

[Digital thorax radiography: flat-panel detector or storage phosphor plates].

Flat panel detectors are characterized by improved handling and increased dose efficiency. This allows for increasing of work flow efficiency and for reducing the exposure dose by about 50% compared to current systems with a sensitivity of 400. Whether the increased dose efficiency should be used to reduce acquisition dose or to increase image quality in the chest, will be shown by further clinical experience and will be also determined by the subjective preference of the radiologists. The decreased level of image noise opens new perspectives for image processing that way that elaborated multifrequency processing allows for optimizing the display of very small and low contrast structures that was so far limited by overlying image noise. Specialized applications of dual energy subtraction and temporal subtraction will also profit by the new detector technology and will be further driven forward in context with applications such as computed assisted diagnosis even though this is currently not yet broadly applied. Storage phosphor radiography still represents an important alternative technique based on its larger flexibility with respect to equipment configuration, its broader application options in intensive care and emergency radiology and due to economic reasons. These facts are further underlined by the fact that image quality also in storage phosphor radiography could be constantly increased by improving detector technology and image processing and consequently has a high standard.

Artifacts↗

Optimization of the composition of phantom materials for computed tomography.

Using available data for photon attenuation and tissue composition, a computer code was developed for the optimization of the composition of phantom materials for diagnostic radiology. The code allows selection of attenuation data in a photon energy range from 1 to 150 keV and the choice of a suitable weight function in the energy interval chosen. For applications in CT imaging a weight function is available reflecting the contribution of the x-ray spectrum to the CT-signal. Several phantom materials for CT were optimized (body fat, trabecular bone, an average bone composition for C4 vertebrae and water) by varying the mineral components in a polymer base in order to adjust x-ray attenuation properties. Measurements with the water equivalent material (PSPP1) showed good agreement of calculated and measured HU values (AHU = 7.3 +/- 5.3 at 80 kVp and 4.0 +/- 2.7 at 140 kVp) and little variation of HU for tube voltages from 80 to 140 kVp. The method provides a fast and flexible means for obtaining optimized phantom materials for a large variety of tissue compositions and energy ranges.

Adipose Tissue↗

A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage.

A method for cardio-thoracic multislice spiral CT imaging with ECG gating for suppression of heart pulsation artifacts is introduced. The proposed technique offers extended volume coverage compared with standard ECG-gated spiral scan and reconstruction approaches for cardiac applications: Thin-slice data of the entire thorax can be acquired within one breath-hold period using a four-slice CT system. The extended volume coverage is enabled by a modified approach for ECG-gated image reconstruction. For a CT system with 0.5-s gantry rotation time, images are reconstructed with 250-ms image temporal resolution. Instead of selecting scan data acquired in exactly the same phase of the cardiac cycle for each image as in standard ECG-gated reconstruction techniques, the patient's ECG signal is used to omit scan data acquired during the systolic phase of highest cardiac motion. With this approach cardiac pulsation artifacts in CT studies of the aorta, of paracardiac lung segments, and of coronary bypass grafts can be effectively reduced.

Aortic Diseases↗

[Imaging techniques and examination protocols in the pediatric emergency].

Paediatric emergencies demand a quick and efficient radiological investigation with special attention to specific adjustments related to patient age and radiation protection. Imaging modalities are improving rapidly and enable to diagnose childhood diseases and injuries more quickly, accurately and safely. This article provides an overview of imaging techniques adjusted to the age of the child and an overview of imaging strategies of common paediatric emergencies. Optimising the imaging parameters (digital radiography, different screen-film systems, exposure specifications) allows for substantial reduction of radiation dose. Spiral- and multislice-CT reduce scan time and enable a considerable reduction of radiation exposure if scanning parameters (pitch setting, tube current) are properly adjusted. MRI is still mainly used for neurological or spinal emergencies despite the advent of fast imaging sequences. The radiologist's task is to select an appropriate imaging strategy according to expected differential diagnosis and to adjust the imaging techniques to the individual patient.

Child↗

New imaging techniques in the treatment guidelines for lung cancer.

Computed tomography (CT) remains the main imaging technique for the preoperative staging and post-therapeutic evaluation of bronchogenic carcinoma. Spiral CT has already overcome some of the problems encountered with central or more extensive tumours. Multislice CT offers further improvement and allows for scanning of the whole chest within a single breath-hold using a thin-section high-resolution technique. Problem-adapted sections in arbitrary directions become available and provide an excellent spatial resolution. One can expect improved accuracy for the evaluation of transfissural tumour growth, chest wall involvement, mediastinal infiltration and lymph node staging. Despite recent advances in magnetic resonance (MR) techniques for imaging the chest, the role of MR for staging of bronchogenic carcinoma remains limited. It offers advantages such as the assessment of chest-wall involvement or mediastinal involvement in patients in whom CT remains equivocal. Lymph-node-specific MR contrast agents offer new diagnostic potential for the assessment of metastatic disease. New techniques for the display of three-dimensional data sets include volume rendering and virtual bronchoscopy. These techniques represent new tools for the evaluation and demonstration of pathology within the central tracheobronchial tree. Their most important application is the guidance of bronchoscopic biopsies. The assessment of an indeterminate pulmonary nodule is frequently based on positron emission tomography imaging. As an alternative, nodule vascularization (contrast enhancement patterns on CT or magnetic resonance imaging (MRI)), calcifications (absorption characteristics at various X-ray energies on CT or dual energy radiography), and morphological features (high resolution imaging at CT) can be used as the basis for nodule differentiation. The dynamics of contrast enhancement in CT or MRI can also be used for the assessment of tumour viability after chemotherapy. Lung cancer screening programmes are still controversial. Low-dose computed tomography scanning and computed assisted detection algorithms based on chest radiographs or computed tomography scans form the technical basis for such projects.

Bronchography↗

[Virtual multislice computed tomographic colonoscopy].

Virtual colonoscopy or computed tomographic (CT) colonography is a rapidly evolving technique for imaging the entire colon and detection of colorectal polyps. It uses standard helical computed tomography images of the colon and advanced imaging software to produce reformatted two- and three-dimensional views of the entire colorectum. Multi-detector row helical computed tomography has several technical advantages over single-detector row computed tomographic, including faster imaging times with the acquisition of thinner sections. The improved speed and spatial resolution of multislice computed tomography promises an increase of sensitivity and specificity, especially for the detection of colorectal lesions.

Colonic Polyps↗

[Current development sin the area of digital thoracic radiography].

All three currently commercially available systems for digital radiography of the chest such as the selenium drum, storage phosphor plates and the flat panel direct detector systems provide an excellent image quality that is at least equivalent or superior to that of conventional film. Reasons for that are the continuously improved detective or dose efficiency of the detector systems and an improved image processing. The new direct detector systems have the largest potential for dose reduction while storage phosphor and selenium radiographs are usually obtained with a dose comparable to that of a 400 speed system. Improved image processing algorithms allow for the production of digital images that are adapted to the conventional image characteristics within the lung regions combined with an increased transparency of the high absorption areas such as the retrocardial and retrodiaphragmatic regions.

Algorithms↗

[Multislice CT of the lung. Technique and clinical applications].

With the advent of multislice technology computed tomography experienced a boost in image quality, comparable to the introduction of spiral CT one decade ago. In the chest, the improved performance may be utilised to scan faster or to obtain an almost isotropic spatial resolution. For examinations of the lungs multislice CT offers considerable advantages over single slice spiral CT: reduced breathing and pulsation artefacts, the ability to cover large volumes with thin slices, the simultaneous evaluation of high resolution and standard imaging protocols from one data acquisition, high resolution multiplanar sections through the lung parenchyma, and 3D techniques like volume rendering and virtual bronchoscopy. In this review the technical principles of multislice CT of the lungs are discussed. Major clinical applications such as evaluation of focal and diffuse lung disease are reviewed.

Artifacts↗

[Optimizing dosage in thoracic computerized tomography].

Radiation exposure in computed tomography (CT) by far exceeds radiation dose in chest radiography. Dose requirements in CT of the chest, however, are much smaller than for the abdomen because of low x-ray absorption in the lungs. This article describes scanner parameters that influence patient exposure and image quality. Suitable compromises will be explained that allow for dose reduction in chest CT without jeopardising image quality. Dose reduction in chest CT should be performed depending on the clinical indication and requires active reduction of mAs settings. For helical CT, a pitch of 1.5 to 2 should be employed. Dedicated low-dose techniques for screening of bronchogenic carcinoma are described. Dose reduction decreases image quality but the detrimental effects can be reduced by applying proper parameters for scanning and image reconstruction. Thus, images of the mediastinum should be reconstructed with a smoothing filter, while a higher resolution filter should be used for the lungs. In multislice CT, reconstruction of thicker axial or multiplanar sections retains spatial resolution but keeps image noise and thus dose requirements low. The effective, weighted CT dose index (CTDIw,eff) can serve as a rough estimate of the effective patient dose (E) in helical or multislice CT of the whole chest: for most scanners and age groups the conversion factors are 0.5 mSv/mGy for females and 0.4 mSv/mGy for males.

Artifacts↗

High-resolution CT of diffuse interstitial lung disease: key findings in common disorders.

High-resolution CT (HRCT) is the radiological imaging technique that most closely reflects changes in lung structure. It represents the radiological method of choice for the diagnostic work-up of patients with known or suspected diffuse interstitial lung disease. A single HRCT finding is frequently nonspecific, but the combination of the various HRCT findings together with their anatomic distribution can suggest the most probable diagnosis. The purpose of this article is to summarize the classic HRCT features of the most common diffuse interstitial lung diseases. Lists of differential diagnoses and distinguishing key features are provided to improve diagnostic confidence. The presence of classic HRCT features often obviates the need for biopsy. In patients with atypical findings, HRCT can be used to determine the most appropriate biopsy site.

Diagnosis, Differential↗

TRITON: graphic software for rational engineering of enzymes.

Engineering of the catalytic properties of enzymes requires knowledge about amino acid residues interacting with the transition state of the substrate. TRITON is a graphic software package for modelling enzymatic reactions for the analysis of essential interactions between the enzyme and its substrate and for in silico construction of protein mutants. The reactions are modelled using semi-empirical quantum-mechanic methods and the protein mutants are constructed by homology modelling. The users are guided through the calculation and data analysis by wizards.

Enzymes↗

[Diagnosis of aortic emergency].

The CT angiography is the diagnostic method of choice in patients with aortic emergencies. It allows for reliable evaluation of aortic dissection, aortic rupture as well postoperative and post-interventional complications. It can be performed rapidly with the option of continuous monitoring of the patient. Transesophageal echocardiography is an alternative primary diagnostic method in patients with aortic dissections. MRI does not play a role due to the limited possibilities for patient monitoring. Only in patients with limited renal function MRI may be employed instead of CT as primary diagnostic modality.

Acute Disease↗