Search PubMedSearch

PubMed · 1114971

Letter: Ventricular function curves.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T O Cheng. 1975. Letter: Ventricular function curves.. https://doi.org/10.1016/0002-8703(75)90099-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Vein compliance: a preoperative indicator of vein morphology and of veins at risk of vascular graft stenosis.

Compliance measurements of 53 long saphenous veins before femorodistal bypass have been performed using a duplex scanner with venous occlusion for distension. These have been compared with the histological features of the veins. There was significantly more moderate or severe focal hyperplasia and circular muscle hypertrophy in distal long saphenous vein than in its proximal counterpart (P < 0.01 and P < 0.05 respectively). The mean (95 per cent confidence interval) compliance of distal vein with moderate or severe hyperplasia was 0.16 (0.13-0.19) compared with 0.29 (0.22-0.36) for that with no, minimal or mild hyperplasia (P = 0.001). The mean compliance of distal vein with moderate or severe muscle hypertrophy was 0.19 (0.17-0.21) and of vein with no, minimal or mild hypertrophy 0.25 (0.21-0.29) (P = 0.14). The mean lowest compliance in seven patients who developed stenosis was 0.10 (0.07-0.13) compared with 0.21 (0.16-0.26) in the rest (P < 0.001). Preoperative measurement of vein compliance can be used to identify vein with marked pre-existing intimal hyperplasia and as a predictor of future graft stenosis.

Compliance

Steady flow through collapsible tubes: measurements of flow and geometry.

Compliant tubes attain a complex three-dimensional geometry when the external pressure exceeds the internal pressure and the tube is partially collapsed. A new technique for remote measurement of dynamic surfaces was applied to classical experiments with collapsible tubes. This work presents measurements of the three-dimensional structure of the tube as well as pressure and flow measurements during static loading and during steady-state fluid flow. Results are shown for two tubes of the same material and internal diameter but with different wall thicknesses. The measured tube laws compare well with previously published data and suggest the possible existence of a similarity tube law. The steady flow measurements did not compare well with the one-dimensional theoretical predictions.

Compliance

Tongue-tip trills and vocal-tract wall compliance.

The effect of vocal-tract wall compliance on tongue-tip trills is to create a favorable pressure-flow relation at the tongue tip for sustained vibration. The governing equations are derived for a model based on this mechanism, and data on unvoiced trills are used to help set parameters for a numerical simulation of the model.

Compliance