Electrochromatography.

Abstract

Although Mould and Synge were credited with the first demonstration of the use of electroosmotic flow to drive a liquid in a thin-layer chromatography system, it was the work of Knox and Grant that extensively detailed much of both the theoretical and practical implications of capillary electrochromatography. This review is aimed at giving a very broad outline of the progression of this technique since the late 1980s up to the present time, including some of the current limitations. Examples will be given of the analysis of a wide variety of materials including neutral, acidic, basic and chiral pharmaceutical compounds, along with some of the instrumentation used for this technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N W Smith, A S Carter-Finch. 2000-09-15. Electrochromatography.. https://doi.org/10.1016/s0021-9673(00)00470-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Micellar electrokinetic chromatography of polyamines and monoacetylpolyamines.

A selective procedure for qualitative and quantitative analysis of ten polyamines by micellar electrokinetic chromatography (MEKC) was developed. Benzoylated polyamines and acetylpolyamines in micellar phase of SDS (10 mM) were separated at 25 degrees C by 20 mM borate buffer pH 8.5, containing 8% ethanol, with an applied voltage of 25 kV (5 microA) and then detected at 198 nm. The experimental factors and operational parameters were optimized by performing analysis at different surfactant concentrations, pH, voltage and temperature with and without ethanol. The repeatibility of migration times and peak heights is a peculiarity of the method here described.

Chromatography, Micellar Electrokinetic Capillary↗

Open-tubular electrochromatography of organic phosphates on a sapphyrin-modified capillary.

Sapphyrin coating of the inner wall of the capillary results in a distinct interaction of the phosphate residue-possessing compounds as proven by a seven-membered model mixture of nucleoside mono- and diphosphates and ATP. Modification of the inner surface of the capillary not only alters the endoosmotic flow (as would have been expected) but brings about an electrochromatographic effect based on the interaction of tested phosphate moiety-bearing solutes with the immobilized sapphyrin layer. Elution of the sample can be achieved by using either 25 mM borate-acetate buffer in which monophosphates are not only separated from each other, but also selectively separated from di- and triphosphates (ATP). With the other two buffer systems tested, i.e. borate-phosphate and Tris-HCl, better selectivity (though smaller interaction with the capillary coating) was observed. The coating is relatively stable (can be used for 20 subsequent runs at least), simple to materialize, and in spite of a strong UV absorbancy of sapphyrin at the wavelength used (254 nm), decreases the limit of detection by no more than one order of magnitude as compared to the untreated capillary. Resolution factors (calculated to the preceding peak) are in most cases better in the electrochromatographic separation mode as compared to the separation in the untreated capillary, which reflects both the decrease in the electroosmotic flow and the interaction with the capillary wall coating.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary-electrochromatographic separations with copolymeric reversed-stationary phase and ion-exchanger-packed columns.

A macroporous, spherical, 7 microm, polystyrene-divinylbenzene (PS-DVB), reversed-phase adsorbent (PRP-1) was evaluated as a stationary phase for the capillary electrochromatographic (CEC) separation of neutral, acidic, and basic analytes of pharmaceutical interest. Electroosmotic flow (EOF) for a PRP-1 packed capillary is nearly constant over the pH 2 to 10 range and is higher than for a silica-based C18 packed capillary on the acidic side. EOF increases with an increase in buffer acetonitrile concentration or as applied potential increases. As analyte hydrophobicity increases, analyte retention and migration time increases. Increasing buffer acetonitrile concentration reduces analyte partitioning with the PS-DVB stationary phase and analyte retention and migration time decreases. When exchange sites are present on the PS-DVB copolymer, EOF (EOF is reversed for the anion-exchanger) increases as the exchange capacity increases. An increased exchange capacity also reduces partitioning of the analyte with the PS-DVB matrix and analyte retention and migration time decrease. Because of excellent stability in an acid environment, the PRP-1 packed capillary can be used in strong acid buffer solution and weak acid and base analytes depending on pKa values can be separated as neutral species and cations, respectively. CEC separations on a PRP-1 capillary of neutral steroids, weak base pharmaceuticals (separation as cations), purines and pyrimidines (as cations), fatty acids (as undissociated species), and sulfa derivatives (as cations) are described. Efficiency for the PRP-1 packed capillary for acetone or thiourea as the analyte is about 6 x 10(4) plates m(-1).

Chromatography, Micellar Electrokinetic Capillary↗