Search PubMed⌕ Search

PubMed · 11030634

Virtual colonography.

Abstract

Cross-sectional imaging techniques are increasingly being considered as alternative imaging modalities for colorectal screening. While CT-colonography uses air to insufflate the colon, an enema containing small amounts of paramagnetic contrast represents the basis for MR-colonography. Both techniques provide large three-dimensional data sets of the abdomen, containing the entire colon. Using sophisticated post-processing, the colon can be assessed in any desirable plane from various viewpoints. Thus even virtual endoscopic views can be rendered to assess the inside of the colon. This chapter briefly describes the technical aspects underlying both CT- and MR-colonography. Advantages and disadvantages of the two techniques are critically discussed, comparing them with one another as well as with conventional colonoscopy and barium enema.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Bauerfeind, W Luboldt, J F Debatin. 1999. Virtual colonography.. https://doi.org/10.1053/bega.1999.0008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (≥18 years of age), reporting mean polyp detection counts stratified by size (≤5 mm, 6-9 mm, and ≥10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and τ2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (≤5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Colonoscopy↗

[National colorectal carcinoma screening program deserves further study; a report from the Dutch Health Council].

Each year there are about 8400 new colorectal carcinoma (CRC) cases in the Netherlands. Despite improved treatment possibilities the mortality rate has not shown a decline. A reduction in the mortality rate can be achieved by screening for CRC by means of faecal occult-blood testing. Endoscopic screening (flexible sigmoidoscopy or colonoscopy) could reduce not only the mortality but also the incidence of CRC, but this has yet to be conclusively demonstrated. The introduction of a national screening programme deserves serious consideration, although various questions need to be answered before a final decision can be taken. These concern the optimal screening strategy, the expected degree of participation, the follow-up under persons in whom polyps are found, the demand on human resources and other resources, and the cost-effectiveness.

Colonoscopy↗