Search PubMed⌕ Search

PubMed · 10959616

Quantitative analysis using the star volume method applied to skeleton patterns extracted with a morphological filter.

Abstract

In this study, a morphological filter was combined with star volume analysis and applied to digital images to determine its potential usefulness in assessing trabecular structure. Three digital "geometric" test patterns (square, rectangle, circle) were created on a CRT (cathode ray tube). Each shape was arranged into five groups by size to yield 15 final "skeletal" patterns that were subsequently assessed with star volume analysis. Also, three digital X-ray images (background, soft tissue, bone block) were processed with a morphological filter to create three sets of 11 skeletal patterns each. These patterns were also assessed with star volume analysis and the ratio of extracted skeletal elements (in pixel numbers) to total pixel numbers was expressed as the pixel percentage. Star volume analysis was then applied to these digital skeletal images to yield the volume of extracted "skeletal" trabecular elements (Vsk) and the volume of nonskeletal (marrow space) elements (Vsp). The Vsk and Vsp were compared for all the different skeletal patterns. The pixel percentages were then compared to the star volume results for the X-ray test patterns. The Vsk decreased and Vsp increased as the number of operations (n) increased for both digital X-ray images and the geometric test patterns when the X-ray images were depicted by pixel percentages. Also, all true bone test patterns were clearly different both visually and quantitatively when compared to the noise skeletons extracted from background and soft tissue. Therefore, as Vsk was increased, so was connectivity. It can be concluded that the application of morphological filters and star volume analysis may be a useful tool in quantitatively determining the characteristics and continuity of trabecular skeletal structures. Further studies involving a larger number of bone samples and using models to compare measurements of calculated versus actual volume should reveal the true potential of this method for evaluating bone structure and its relationship to bone strength and also increase the tools available for evaluating bone diseases such as osteoporosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Ikuta, S Kumasaka, I Kashima. 2000. Quantitative analysis using the star volume method applied to skeleton patterns extracted with a morphological filter.. https://doi.org/10.1007/pl00010641

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of impact loads on the femur.

OBJECTIVE: To investigate the stress distribution and fracture mechanism of proximal femur under impact loads. METHODS: The image data of one male's femur were collected by the Lightspeed multi-lay spiral computed tomography. A 3D finite element model of the femur was established by employing the finite element software ANSYS, which mainly concentrated on the effects of the directions of the impact loads arising from intense movements and the parenchyma on the hip joint as well as those of the femur material properties on the distribution of the Mises equivalent stress in the femur after impact. RESULTS: The numerical results about the effects of the angle sigma of the impact loads to the anterior direction and the angle gamma of the impact loads to the femur shaft on the bone fracture were given. The angle sigma had larger effect on the stress distribution than the angle gamma, which mainly represented the fracture of the upper femur including the femoral neck fracture when the posterolateral femur was impacted. This result was consistent with the clinical one. The parenchyma on the hip joint has relatively large relaxation effect on the impact loads. CONCLUSIONS: A 3D finite element analysis model of the femoral hip joint under dynamic loads is successfully established by using the impact dynamic theory.

Femur↗

A convex lateral tibial plateau for knee replacement.

Unicompartmental knee replacements have not performed as well in the lateral compartment as in the medial. This may be because the tibial components have flat or slightly concave surfaces which match the medial plateau but not the convex lateral plateau. The aim of this study was to find the optimal radius for a convex lateral tibial component. Twelve normal lateral tibial plateau were retrieved at knee replacement, and their surface contour in their mid sagittal plane was determined. The optimal circle was fitted and its radius measured. A series of different shaped tibial components were superimposed. From published information about the position of the femoral condyle relative to the tibia in different degrees of flexion, the flexion gap at these angles was determined. The average radius of the lateral tibial plateau was 40 mm. However, as the surface was polyradial it was not clear if this average radius would be optimal. In full flexion, a flat tibial plateau distracted the knee by 8 mm (p<0.001). A 75 mm radius spherical tibial plateau did not alter the knee kinematics significantly and gave rise to a change in joint distraction of 1.5 mm. Spherical tibial plateau of 50 mm and 25 mm radii significantly altered knee kinematics (p<0.001) and resulted in changes in distraction of 3 mm and 4 mm respectively. The optimal shape for a unicompartmental lateral tibial plateau is likely to be a spherical dome with radius of about 75 mm. The incorporation of this shape in the lateral side of a total knee replacement might improve its flexion.

Femur↗

Common misconceptions of normal hip joint relations on pelvic radiographs.

This study defines normal bilateral variations in offset and hip center location on pelvic radiographs. The relationship of the femoral head center to the tip of the greater trochanter and that of offset to medullary canal diameter are also defined. Measurements of the offset, hip center location, height of the tip of the greater trochanter from the femoral head center, and medullary canal diameter were carried out on 100 normal pelvic radiographs. The offset of one hip was found to predict that of the contralateral hip to within 4.62 mm with 95% confidence. Their hip center locations differed by 6.3 mm. The tip of the greater trochanter was, on average, 8 mm higher than the femoral head center. Although offset generally increased with an increase in medullary canal diameter, frequent discrepancies occurred in their relationship.

Femur↗