[Acoustic reflection technique].

Abstract

Acoustic reflection technique has been employed to assess the pharyngeal cross-sectional area in sleep apnea patients. It has the advantage of being noninvasive and quick, and it also allows for continuous evaluation of the patency of these regions. The technique, however, has never been used during sleep because of its restrictions. This issue overlook the recent progress of the technique, i.e., the newly developed nasal acoustic reflection technique which enabled us to assess the pharyngeal cross-sectional area during sleep. Application of this technique includes a method of determining the site of pharyngeal occlusion, a method of evaluating the efficiency of various therapeutic methods of sleep apnea, and a method of measuring the upper airway collapsibility during sleep.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Huang, N Ohya. 2000. [Acoustic reflection technique].. https://pubmed.ncbi.nlm.nih.gov/10944928/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A portable, high-speed, vacuum-outlet GC vapor analyzer employing air as carrier gas and surface acoustic wave detection.

Vacuum-outlet GC with atmospheric-pressure air as the carrier gas is implemented at outlet pressures up to 0.8 atm using a low-dead-volume polymer-coated surface acoustic wave (SAW) detector. Increases in the system outlet pressure from 0.1 to 0.8 atm lead to proportional increases in detector sensitivity and significant increases in column efficiency. The latter effect arises from the fact that optimal carrier gas velocities are lower in air than in more conventional carrier gases such as helium or hydrogen due to the smaller binary diffusion coefficients of vapors in air. A 12-m-long, 0.25-mm-i.d. tandem column ensemble consisting of 4.5-m dimethyl polysiloxane and 7.5-m trifluoropropylmethyl polysiloxane operated at an outlet pressure of 0.5 atm provides up to 4 x 10(4) theoretical plates and a peak capacity of 65 (resolution, 1.5) for a 3-min isothermal analysis. At 30 degrees C, mixtures of vapors ranging in vapor pressure from 8.6 to 76 Torr are separated in this time frame. The SAW detector cell has an internal volume of < 2 microL, which allows the use of higher column outlet pressures with minimal dead time. The sensor response is linear with solute mass over at least 2-3 decades and provides detection limits of 20-50 ng for the vapors tested. The combination of atmospheric-pressure air as carrier gas, modest operating pressures, and SAW sensor detection is well-suited for field instrumentation since it eliminates the need for support gases, permits smaller, low-power pumps to be used, and provides sensitivity to a wide range of vapor analytes.

Acoustics↗

Acoustic and electroacoustic spectroscopy for characterizing concentrated dispersions and emulsions.

We describe two different techniques (acoustics and electroacoustics), both of which employ ultrasound instead of light for extracting information about the properties of liquid-based dispersions. Ultrasound can propagate through samples that are not transparent for light, which open up many new applications not possible with classical light scattering methods. Acoustic and electroacoustic techniques offer a unique opportunity to characterize concentrated dispersion, emulsions and microemulsions in their natural states. Elimination of a dilution step required for most other techniques (light scattering, sedimentation, electrophoresis) is crucial for an adequate characterization of liquid dispersions, especially when the high concentration leads to structured systems. As with any macroscopic method, ultrasonic techniques characterize the sample in two steps. The first step is to measure some macroscopic property. The second step involves some theoretical treatment of the measured raw data which yields the desired information. Acoustic spectroscopy deals with measuring the attenuation of ultrasound within a certain frequency range. Electroacoustic spectroscopy has two implementations depending on the driving force. We emphasize here on the so-called Colloid Vibration Current (CVI) which is generated by the sound wave as it passes through the dispersion. A review of the theoretical basis of acoustics and electroacoustics is given, with emphasis on models that have been applied to concentrated systems. Recently, new theories have been developed for both acoustics and electroacoustics using a 'coupled phase model' and 'cell model concept'. The coupled phase model is widely used for describing a relative motion of the particles and liquid in the sound wave. The cell model approach opens the way to include both particle-particle interactions and polydispersity into the theoretical model. Experimental evidence is presented that shows that this new approach is successful in concentrated systems up to 45% vol. A short review of the possible applications of acoustics and electroacoustics measurements to a range of systems is presented including: ceramics, mixed dispersed systems, chemical-mechanical polishing abrasives, emulsions, microemulsions and latex materials.

Acoustics↗

Avalanche dynamics of crackle sound in the lung.

We analyze a sequence of short transient sound waves, called "crackles," which are associated with explosive openings of airways during lung inflation. The distribution of time intervals between consecutive crackles Delta(t) shows two regimes of power law behavior. We develop an avalanche model which fits the data over five decades of Delta(t). We find that the regime for large Delta(t) is related to the dynamics of distinct avalanches in a Cayley tree, and the regime for small Delta(t) is determined by the dynamics of crackle propagation within a single avalanche. We also obtain a mean-field solution of the model which provides information about lung inflation.