Beam intensity modulation using tissue compensators or dynamic multileaf collimation in three-dimensional conformal radiotherapy of primary cancers of the oropharynx and larynx, including the elective neck.

Abstract

INTRODUCTION: The treatment of midline tumors in the head and neck by conventional radiotherapy almost invariably results in xerostomia. This study analyzes whether a simple three-dimensional conformal radiotherapy (3D-CRT) technique with beam intensity modulation (BIM) (using a 10-MV beam of the MM50 Racetrack Microtron) can spare parotid and submandibular glands without compromising the dose distribution in the planning target volume (PTV). METHODS: For 15 T2 tumors of the tonsillar fossa with extension into the soft palate (To) and 15 T3 tumors of the supraglottic larynx (SgL), conventional treatment plans, consisting of lateral parallel opposed beams, were used for irradiation of both the primary tumor (70 Gy) and the elective neck regions (46 Gy). Separately, for each tumor a 3-D conformal treatment plan was developed using the 3-D computer planning system, CadPlan, and Optimize, a noncommercial program to compute optimal beam profiles. Beam angles were selected with the intention of optimal sparing of the salivary glands. The intensity of the beams was then modulated to achieve a homogeneous dose distribution in the target for the given 3D-CRT techniques. The dose distributions, dose-volume histograms (DVHs) of target and salivary glands, tumor control probabilities (TCPs), salivary gland volumes absorbing a biologically equivalent dose of greater than 40 or 50 Gy, and normal tissue complication probabilities (NTCPs) of each treatment plan were computed. The parameters of the 3D-CRT plans were compared with those of the conventional plans. RESULTS: In comparison with the conventional technique, the dose homogeneity in the target volume was improved by the conformal technique for both tumor sites. In addition, for the SgL conformal technique, the average volumes of the parotid glands absorbing a BED of greater than 40 Gy (V40) decreased by 23%, and of the submandibular glands by 7% (V40) and 6% (V50). Consequently, the average NTCPs for the parotid and submandibular glands were reduced by 7% and 6%, respectively. For the To conformal techniques, the V40 of the parotid glands was decreased on average by 31%, resulting in an average reduction of the NTCP by 49%. Both the average V50 and the NTCP of the submandibular glands were decreased by 7%. CONCLUSION: For primary tumors of the oropharynx, the parotid glands could be spared to a considerable degree with the 3D-CRT technique. However, particularly the ipsilateral submandibular gland could not be spared. For primary tumors of the larynx, the 3D-CRT technique allows sparing of all salivary glands to a considerable and probably clinically relevant degree. Moreover, the conformal techniques resulted in an increased dose homogeneity in the PTV of both tumor sites.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E B van Dieren, P J Nowak, O B Wijers, J R van Sörnsen de Koste, H van der Est, D P Binnekamp, B J Heijmen, P C Levendag. 2000-07-15. Beam intensity modulation using tissue compensators or dynamic multileaf collimation in three-dimensional conformal radiotherapy of primary cancers of the oropharynx and larynx, including the elective neck.. https://doi.org/10.1016/s0360-3016(00)00564-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A feasibility study on the use of visible and short wavelengths in the near-infrared region for the non-destructive measurement of wine composition.

The aim of this study was to explore the capability of spectroscopy in the visible (Vis) and short wavelength near-infrared (NIR) regions for the non-destructive measurement of wine composition in intact bottles. In this study we analysed a wide range of commercial wines obtained in Australia in different types of bottles (e.g. colours, diameters and heights), including different wine styles and varieties. Wine bottles were scanned in the Vis-NIR region (600-1,100 nm) in a monochromator instrument in transflectance mode. Principal component analysis (PCA) and partial least-squares (PLS) regression were used to interpret the spectra and develop calibrations for wine composition. Due to the relatively small number of samples available full cross-validation (leave-one-out) was used as validation. The coefficient of correlation in calibration [Formula: see text] and the standard error of cross-validation (SECV) were 0.67 (SECV: 0.48%), 0.83 (SECV: 4.01 mg L-1), 0.70 (SECV: 28.6 mg L-1) and 0.50 (SECV: 0.15) for alcohol content, total SO2, free SO2 and pH, respectively, in the set of wine samples analysed. These preliminary results showed that the assessment of wine composition by Vis and short wavelengths in the NIR is possible for either qualitative analysis (e.g. low-, medium- and high-quality grading), or for screening of composition during bottling and storage. Although low accuracy and precision were obtained for the chemical parameters routinely analysed in wine, calibration models for the chemical parameters were considered acceptable for screening purposes in terms of the standard errors obtained.

Feasibility Studies↗

Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer.

PURPOSE: In external beam radiotherapy (EBRT) and especially in intensity-modulated radiotherapy (IMRT), the accuracy of the dose distribution in the patient is of utmost importance. It was investigated whether image guided in vivo dosimetry in the rectum is a reliable method for online dose verification. METHODS AND MATERIALS: Twenty-one dose measurements were performed with an ionization chamber in the rectum of 7 patients undergoing IMRT for prostate cancer. The position of the probe was determined with cone beam computed tomography (CBCT). The point of measurement was determined relative to the isocenter and relative to an anatomic reference point. The dose deviations relative to the corresponding doses in the treatment plan were calculated. With an offline CT soft-tissue match, patient positioning after ultrasound was verified. RESULTS: The mean magnitude +/- standard deviation (SD) of patient positioning errors was 3.0 +/- 2.5 mm, 5.1 +/- 4.9 mm, and 4.3 +/- 2.4 mm in the left-right, anteroposterior and craniocaudal direction. The dose deviations in points at corresponding positions relative to the isocenter were -1.4 +/- 4.9% (mean +/- SD). The mean dose deviation at corresponding anatomic positions was 6.5 +/- 21.6%. In the rare event of insufficient patient positioning, dose deviations could be >30% because of the close proximity of the probe and the posterior dose gradient. CONCLUSIONS: Image-guided dosimetry in the rectum during IMRT of the prostate is a feasible and reliable direct method for dose verification when probe position is effectively controlled.

Feasibility Studies↗