Search PubMed⌕ Search

PubMed · 10874393

[Fast imaging sequences].

Abstract

Although conventional spin echo and gradient echo sequences are still in general use, the need to improve the temporal resolution of MRI and to study organ function has prompted to develop fast imaging techniques. These techniques are based on different approaches, but present common underlying principles which allow optimize k space fitting. As a result, both contrast and spatial resolution may be improved aside from the capability to reduce scan time. The selection of the most appropriate fast imaging technique will depend on the needed temporal resolution, spatial resolution and contrast. The aim of this paper is to review and explain the basic principles of fast imaging techniques, with emphasis on their advantages, limitations, and clinical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E de Kerviler, J M Franconi, J Frija. 1999. [Fast imaging sequences].. https://pubmed.ncbi.nlm.nih.gov/10874393/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor.

PURPOSE: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. METHODS AND MATERIALS: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second. The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. RESULTS: The coordinates of the marker were detected with an accuracy of +/- 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a "tight" planning target volume (PTV) margin. They were surviving without relapse or complications with a median follow-up of 6 months. CONCLUSION: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors.

Computer Systems↗