A new fast and unsynchronized method for MRI of viscoelastic properties of soft tissues.

Quantitative measurement of mechanical properties of biologic tissues may have several applications for diagnosis or biomechanic modeling in sports medicine, traumatology, or computer-guided surgery. The magnetic resonance imaging (MRI) methods previously tested for these applications all required synchronization between MRI acquisition pulses and the mechanical stimulation. A new unsynchronized method operating with no prior knowledge of intensity, direction, and frequency of the mechanical waves is proposed. A specifically modified SPAMM (SPAtial Modulation of Magnetization) sequence has been used, operating on a 0.2-T MRI system. The experimental results obtained on test objects fit well with theoretical calculations. The new proposed method is very fast (a less than 5-second acquisition time) for routine clinical use.

Biomechanical Phenomena↗

[Comparative assessment of helical CT-angiography, 2D TOF MR-angiography and 3D gadolinium enhanced MRA in aorto-iliac occlusive disease].

PURPOSE: To compare helical CT-angiography (CTA) and two techniques of MR angiography (MRA) to conventional angiography in aorto-iliac occlusive disease. MATERIALS AND METHODS: The abdominal aorta and iliac arteries in 22 patients (4 for preoperative assessment of abdominal aortic aneurysm and 18 for peripheral vascular disease) were imaged using four techniques: digital subtraction angiography ("gold standard"), 2D TOF MR angiography, 3D Gd-enhanced MR angiography and helical CT angiography. Source (CTA and 2D TOF MRA) and MIPed images (after subtraction measures before and after gadolinium injection for 3D Gd-MRA) were reviewed. RESULTS: Sensitivity, specificity and accuracy for the detection of significant (>50%) stenosis and occlusion of aorto-iliac arteries were respectively: 38%, 89%, 77% for 2D TOF MRA; 75%, 71%, 72% for 3D Gd-MRA and 95%, 90%, 92% for CTA. Excluding the internal iliac arteries, results were 54%, 96%, 88% for 2D TOF MRA; 96%, 80%, 83% for 3D Gd-MRA and 92%, 93%, 95% for CTA. CONCLUSION: 3D Gd-MRA, a technique with potential for further improvement, is superior to 2D TOF MRA for detecting significant stenosis and occlusion of aorto-iliac arteries. Results at Gd-MRA are nearly similar to those at CTA (after excluding internal iliac arteries). Results at Gd-MRA are not affected by calcified plaque.

Adult↗

A multicenter measurement of magnetization transfer ratio in normal white matter.

To assess the importance of intercenter variations when measuring magnetization transfer ratio (MTR) in the brain, six European centers measured MTR in normal white matter. MTR ranged from 9 to 51 percent units (25 sequences). The effective flip angle of the saturating pulse divided by the pulse repetition time (ENRsat degrees/msec) was a good predictor of MTR (MTR = 3.25 ENRsat).

Brain↗

Cinematic study of temporomandibular joint motion using ultra-fast magnetic resonance imaging.

Magnetic Resonance Images (MRI) of the temporomandibular joint (TMJ) are usually performed to study the opening/closing movements of the mandible and have up to now been pseudodynamic step-by-step images simulating condylar motion by post-processing reconstruction. The aim of this study was: 1. to optimize a TMJ cine-imaging method to give a better clinical result than the step-by-step methods; 2. to develop an ultra-fast MRI Gradient Echo (GE) sequence for this purpose; and 3. to analyze condylar movements in the sagittal, coronal and para-axial planes during border mandibular displacements and chewing. Both TM joints were studied in six asymptomatic volunteers. The method involved a compromise between in-plane resolution, slice thickness, signal-to-noise ratio and time resolution. Routine clinical use was found to be a GE pulse sequence providing three images per second with an isometric voxel resolution of approximately two millimeters in ridge. This did not allow visualization of the disk. Using this sequence enabled real and simultaneous condylar displacement observation in the three planes of space and therefore contributed to a better functional diagnosis of pathologic TMJ motions.

Adolescent↗

Gadolinium-enhanced MR imaging of normal renal transplants. An evaluation of a T1-weighted dynamic echo-planar sequence.

PURPOSE: To evaluate the potential usefulness of dynamic MR with echoplanar imaging (EPI) in assessing the renal function in patients with renal allografts. MATERIAL AND METHODS: Using a T1-weighted sequence, EPI was performed after injection of a Gd-chelate in 17 patients with normally functioning renal allografts. Time-intensity curves were plotted from the signal intensity (SI) measurements of the cortex and the medulla. RESULTS: The pattern of corticomedullar differentiation (CMD) observed after contrast enhancement was divided into four phases using the T1-EPI. After a rapid decrease in the SI of cortical structures, and a subsequent return to precontrast levels, a gradual fall in the SI of the medulla was observed. The average time between the two periods of signal loss was 60 s. CONCLUSION: This study illustrated the potential use of dynamic T1-EPI to demonstrate contrast-induced CMD in renal allografts.

Adult↗

[Fast imaging sequences].

Although conventional spin echo and gradient echo sequences are still in general use, the need to improve the temporal resolution of MRI and to study organ function has prompted to develop fast imaging techniques. These techniques are based on different approaches, but present common underlying principles which allow optimize k space fitting. As a result, both contrast and spatial resolution may be improved aside from the capability to reduce scan time. The selection of the most appropriate fast imaging technique will depend on the needed temporal resolution, spatial resolution and contrast. The aim of this paper is to review and explain the basic principles of fast imaging techniques, with emphasis on their advantages, limitations, and clinical applications.

Computer Systems↗

A validation of a flow quantification by MR phase mapping software.

AIM: We evaluated a Siemens software of flow quantification (FQ) by MR phase mapping, in the framework of a common practical use. METHODS: Experiments with a laminar flow phantom and in vivo pulsatile flow were performed. In particular, FQ in ascending aorta was investigated in healthy volunteers. RESULTS AND CONCLUSION: Flow phantom experiments reveal that the FQ slightly underestimates (8% on the average) actual velocities (mean velocities over a vessel area), and also that velocity uncertainties are related to the encoding velocity value, whatever the measured velocity. Furthermore, using well characterized working criteria, we found low intraobserver variability and negligible interobserver variability in ascending aorta FQs. The role played by the choice of reference area in FQ accuracy is emphasized. When recording several cardiac cycles during the same acquisition, it is shown that the FQ software may provide erroneous results. Several comments for FQ software use in the ascending aorta are added.

Adult↗

Magnetization transfer with echo planar imaging.

The aim of magnetization transfer is to saturate the protons of the macromolecule pool with a radiofrequency (RF) pulse leading to differences in free water pool signal. Magnetization transfer (MT) contrast is difficult to achieve with the echo planar imaging (EPI) technique, although its short acquisition time would be most beneficial. Indeed, the RF saturation pulses can only be applied once before sampling the whole k-space in a single-short sequence. A possible solution to improve the sensitivity of EPI to magnetization transfer consists in applying a train of several saturation RF pulses before image acquisition. The different parameters of a RF pulse train and their influence on the MT rate have been tested to optimize an EPI clinical sequence. Our experimental procedure makes it possible to obtain a MT map in about 1 second. The technique is evaluated by multiple sclerosis lesion characterization.

Adult↗

Auditory cortex activation in deaf subjects during cochlear electrical stimulation. Evaluation by functional magnetic resonance imaging.

RATIONALE AND OBJECTIVES: The authors detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using functional magnetic resonance (MR) imaging. METHODS: Stimulating electrode was inserted gently under local anesthesia close to the round window membrane of the cochlea in seven cochlear implant candidates. These patients suffered from postlingual-acquired deafness. Four patients were stimulated above the electrical perception threshold and three below the electrical discomfort threshold. Functional scans (fast low-angle shot 91 mseconds/60 mseconds) were acquired in an oblique axial plane running parallel to the sylvian fissure. Four consecutive series of six images were obtained in 6 minutes. The acquisition time of each image was 15 seconds. RESULTS: During electrical cochlear stimulation below the discomfort threshold, the three patients described "auditory" sensations with activation of the superior temporal regions. In two patients with electrical stimulation of the left ear, the maximum signal intensity increased by 8.42% in the right auditory cortex and 5.69% in the left. In one patient with a right electrical stimulation only the left cortex was activated. Electrical cochlear stimulation above the perception threshold induces no significant activation in the auditory cortex. CONCLUSION: Functioning MR imaging can detect activation in the auditory cortex during cochlear electrical stimulation in deaf patients using a conventional 1.5-tesla system in a routine hospital environment. Further studies are needed to investigate its usefulness in clinical practice.

Adult↗

[Progressive multifocal leukoencephalopathy. Study of the demyelination by magnetization transfer].

PURPOSE: magnetization transfer imaging (MT) has been used to study the degree of demyelination in progressive multifocal leukoencephalopathy (PML). MATERIAL AND METHOD: two groups were studied: a group of 10 HIV + patients with clinical, MR features, biological and/or biopsy proven PML, and a group of 11 normal volunteers with matched age. MT ratio (MTR) were obtained from the center of the PML lesions and 11 areas of normal appearing white matter (NAWM) in the control group. RESULTS: the mean MTR of NAWM in the control group was 46.6% (SD = 2,3). PML lesions demonstrated a strong and significant (p = 0) decreased of the MTR with mean MTR value of 22.4% (SD = 2,3). CONCLUSION: MT characterized the demyelinating process in PML, and can be used to improve diagnosis. Furthermore, MT allowed a quantification of the degree of demyelination which can be helpful in other demyelinating process of CNS such as multiple sclerosis.

Adult↗

Activation of association auditory cortex demonstrated with functional MRI.

Activations in the temporal lobes previously observed using positron emission tomography and auditory stimuli were partially reproduced with functional MRI and echo-planar imaging at 1.5 T in six volunteers performing tone and phoneme monitoring tasks. Verbal processing compared to a tone recognition task significantly activated a cortical area located in the left anterior temporal region (P < 0.02).

Adult↗

Lateralization of prefrontal activation during internal mental calculation: a functional magnetic resonance imaging study.

1. Functional magnetic resonance imaging (fMRI) at 1.5 T was used to investigate the lateralization of prefrontal cortex activity during internal mental calculation in 16 human volunteers (8 right-handed and 8 left-handed). Subjects were asked to perform two different tasks: 1) a serial subtraction of prime numbers and 2) a control task in which they mentally recited numbers. 2. Signal modifications were regularly observed in the prefrontal cortex (Brodmann's area 46) during the serial subtraction of prime numbers, whereas the number listing task poorly activated the same areas. 3. In right-handed subjects, activation was clearly lateralized in the left dorsolateral prefrontal cortex, whereas a frequent bilateral activation was found in left-handed subjects. 4. We conclude that prefrontal activation during mental calculation is lateralized in a manner similar to that reported during linguistic tasks, i.e., a clear lateralization in right- but not in left-handed subjects.

Adult↗

Use of magnetisation transfer contrast to improve cerebral 3D MR angiography.

To improve 3D-time of flight (3D-TOF) magnetic resonance angiography, we used magnetisation transfer (MT) to increase the contrast between flowing blood and stationary tissues. With a 1.5 KHz off-resonance radio-frequency MT applied for 16 ms at a maximum power within specific absorption rate (SAR) limits, a 37% decrease in the signal of white matter was obtained, whereas the signal from flowing blood decreased by only 8%. An improvement in maximum intensity projection (MIP) image quality was obtained all MT-3DTOF studies on seven volunteers using progressively more powerful MT pulses. Routine clinical use of MT-3DTOF appears promising and can be achieved at any strength field.

Adult↗

First-pass evaluation of renal perfusion with TurboFLASH MR imaging and superparamagnetic iron oxide particles.

First-pass intrarenal hemodynamics were studied with superparamagnetic iron oxide particles and a T2-weighted TurboFLASH (fast low-angle shot) magnetic resonance (MR) imaging sequence. Four groups of five rabbits each were imaged after bolus injection of 40, 100, 140, and 200 mumol/kg iron, respectively. Images were acquired every 1.2 seconds, with an acquisition time of 700 msec. The signal intensity was measured in the cortex, outer medulla, inner medulla, and globally. In preliminary pathologic applications, two rabbits were imaged after ligation of the lumbar ureter and two after embolization of the renal artery. The reproducibility of the normal dynamics was evaluated with a cross-correlation test. On the images, the intravascular progression of the iron particles could be visualized within the cortex and the two compartments of the medulla in all cases. The maximal reduction in signal intensity in the cortex and medulla increased with the dose. The relationship between signal intensity decrease and dose was not linear, and the reproducibility of the signal intensity versus time plots was acceptable only at the 140 and 200 mumol/kg doses. The decrease in signal intensity was reduced and delayed in the embolized and hydronephrotic kidneys.

Animals↗