Search PubMed⌕ Search

PubMed · 10853060

A system for microscope-assisted guided interventions.

Abstract

We present a system for surgical navigation using stereo overlays in the operating microscope aligned to the operative scene. This augmented reality system provides 3D information about nearby structures and offers a significant advancement over pointer-based guidance, which provides only the location of one point and requires the surgeon to look away from the operative scene. With a previous version of this system, we demonstrated feasibility, but it became clear that to achieve convincing guidance through the magnified microscope view, a very high alignment accuracy was required. We have made progress with several aspects of the system, including automated calibration, error simulation, bone-implanted fiducials and a dental attachment for tracking. We have performed experiments to establish the visual display parameters required to perceive overlaid structures beneath the operative surface. Easy perception of real and virtual structures with the correct transparency has been demonstrated in a laboratory and through the microscope. The result is a system with a predicted accuracy of 0.9 mm and phantom errors of 0.5 mm. In clinical practice errors are 0.5-1.5 mm, rising to 2-4 mm when brain deformation occurs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A P King, P J Edwards, C R Maurer, D A de Cunha, D J Hawkes, D L Hill, R P Gaston, M R Fenlon, A J Strong, C L Chandler, A Richards, M J Gleeson. 1999. A system for microscope-assisted guided interventions.. https://doi.org/10.1159/000029708

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Surgical management for upper thoracic spine tumors by a transmanubrium approach and a new space.

The anterior aspect of the upper thoracic spine is a difficult region to approach in spinal surgery. Many vital structures including osseus, articular, vascular and nervous ones hinder the exposure. With increasing frequency, spine surgeons are being asked to provide decompression and stabilization in patients with spinal tumors. The traditional exposure is between the esophagus and trachea medially and the left common carotid or the brachiocephalic artery (BCA) laterally, and the disadvantages were that the ligation and section of the left innominate vein is proposed to reach T4 and the injury of the thoracic duct could occur. The right space of the BCA or the ascending aorta (AA) (the exposure between the right brachiocephalic vein and the BCA or between the AA and superior caval vein) is recommended in exposing the upper thoracic vertebrae; this new space is technically feasible; the exposure is sufficient for vertebral body resection and reconstruction and fixation. Twenty-eight patients with upper thoracic spine tumors underwent surgery by the use of this new space between June 2000 and October 2005. A strut graft was fixed anteriorly after decompression of the spinal cord. Levels C7-T5 can be well exposed through this new space, allowing complete vertebral body removal at level T1-T4. After body removal, the posterior longitudinal ligament is well exposed, allowing complete release of the spinal cord. Curettage was performed in one case of aneurysmal bone cyst and three cases of bone giant cell tumors. For other tumors, vertebrectomies or sagittal resections were performed. Four patients underwent surgery by a combination of anterior and posterior approach.

Bone Cysts↗

Temporomandibular joint clicking noises caused by a multilocular bone cyst: a case report.

When diagnosing patients with temporomandibular disorder (TMD) symptoms, the possibility of unusual causes must be considered, including neoplastic disorders, as well as infections and inflammatory disease. Therefore, radiologic examination may prove to be invaluable in the differential diagnosis of TMDs. This article describes a patient whose temporomandibular joint (TMJ) noise was initially diagnosed by another dental clinic as a TMJ anterior disc displacement with reciprocal clicking. Occlusal splint therapy was used for nearly three to four months but did not improve the TMJ noise condition. When the patient was examined clinically and imaged with magnetic resonance imaging (MRI) and computed tomography (CT), a multilocular bone cyst (MBC) was suspected. The cyst could cause surface irregularities in the posterior part of the left eminence of the temporal bone, which could be the source of the clicking noise.

Bone Cysts↗

A bullet-sired bone cyst.

Random gunfire deposited a bullet in the proximal tibial metaphysis of a 9-year-old girl. The wound was not incapacitating and was treated conservatively. Within 17 months, soreness developed in the proximal leg, and radiography revealed a large unicameral cyst within which the bullet freely tumbled. Eventually, fear of impending fracture prompted further radiography, computed tomography, surgical intervention and pathological examination of the cyst wall. We believe this is only the second description in the English-language literature of this rare sequence of events.

Bone Cysts↗