Search PubMed⌕ Search

Biomedical subjects

R P Gaston

Publications and source records attributed to R P Gaston.

3 recordsLinked to original sources

Design and evaluation of a system for microscope-assisted guided interventions (MAGI).

The problem of providing surgical navigation using image overlays on the operative scene can be split into four main tasks--calibration of the optical system; registration of preoperative images to the patient; system and patient tracking, and display using a suitable visualization scheme. To achieve a convincing result in the magnified microscope view a very high alignment accuracy is required. We have simulated an entire image overlay system to establish the most significant sources of error and improved each of the stages involved. The microscope calibration process has been automated. We have introduced bone-implanted markers for registration and incorporated a locking acrylic dental stent (LADS) for patient tracking. The LADS can also provide a less-invasive registration device with mean target error of 0.7 mm in volunteer experiments. These improvements have significantly increased the alignment accuracy of our overlays. Phantom accuracy is 0.3-0.5 mm and clinical overlay errors were 0.5-1.0 mm on the bone fiducials and 0.5-4 mm on target structures. We have improved the graphical representation of the stereo overlays. The resulting system provides three-dimensional surgical navigation for microscope-assisted guided interventions (MAGI).

Computer Simulation↗

A system for microscope-assisted guided interventions.

We present a system for surgical navigation using stereo overlays in the operating microscope aligned to the operative scene. This augmented reality system provides 3D information about nearby structures and offers a significant advancement over pointer-based guidance, which provides only the location of one point and requires the surgeon to look away from the operative scene. With a previous version of this system, we demonstrated feasibility, but it became clear that to achieve convincing guidance through the magnified microscope view, a very high alignment accuracy was required. We have made progress with several aspects of the system, including automated calibration, error simulation, bone-implanted fiducials and a dental attachment for tracking. We have performed experiments to establish the visual display parameters required to perceive overlaid structures beneath the operative surface. Easy perception of real and virtual structures with the correct transparency has been demonstrated in a laboratory and through the microscope. The result is a system with a predicted accuracy of 0.9 mm and phantom errors of 0.5 mm. In clinical practice errors are 0.5-1.5 mm, rising to 2-4 mm when brain deformation occurs.

Bone Cysts↗

Stereo augmented reality in the surgical microscope.

We present an augmented reality system that allows surgeons to view features from preoperative radiological images accurately overlaid in stereo in the optical path of a surgical microscope. The purpose of the system is to show the surgeon structures beneath the viewed surface in the correct 3-D position. The technical challenges are registration, tracking, calibration and visualisation. For patient registration, or alignment to preoperative images, we use bone-implanted markers and a dental splint is used for patient tracking. Both microscope and patient are tracked by an optical localiser. Calibration uses an accurately manufactured object with high contrast circular markers which are identified automatically. All ten camera parameters are modelled as a bivariate polynomial function of zoom and focus. The overall system has a theoretical overlay accuracy of better than 1 mm. Implementations of the system have been tested on seven patients. Recent measurements in the operating room conformed to our accuracy predictions. For visualisation the system has been implemented on a graphics workstation to enable high frame rates with a variety of rendering schemes. Several issues of 3-D depth perception remain unsolved, but early results suggest that perception of structures in the correct 3-D position beneath the viewed surface is possible.

Depth Perception↗