Search PubMed⌕ Search

PubMed · 10839129

Single-cell analysis avoids sample processing bias.

Abstract

Microscale separation tools such as capillary chromatography and capillary electrophoresis (CE) allow the study of metabolism in individual cells. In this work, we demonstrate that single-cell analysis describes metabolism more accurately than analysis of cellular extracts. We incubated HT29 cells (human colon adenocarcinoma) with a fluorescently labeled metabolic probe. This disaccharide, LacNAc, was labeled with a fluorescent dye, tetramethylrhodamine (TMR). The probe was taken up by the cells and metabolized to a number of products that retained the fluorescent label. We then split the cells into two batches. A cellular extract was prepared from one batch and analyzed by CE with laser-induced fluorescence (LIF) detection. The cells from the second batch were used for single-cell analysis by CE-LIF. Separation and detection conditions were identical for extract and single-cell analyses. We found that the electropherogram obtained by averaging the results from a number of single cells differed significantly from the cell extract electropherogram. Differences were due to sample processing during extract preparation. Disruption of the cells liberated enzymes that were compartmentalized within the cell, which allowed non-metabolic reactions to proceed. The accumulation of these non-metabolic products introduced a bias in the cell extract assay. During single-cell analysis, cells were lysed inside the capillary and the separation voltage was applied immediately to separate the enzymes from their substrates and prevent non-metabolic reactions. This paper is the first to report that CE analysis of single cells provides more accurate metabolic information than the CE analysis of a cellular extract.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S N Krylov, E Arriaga, Z Zhang, N W Chan, M M Palcic, N J Dovichi. 2000-04-28. Single-cell analysis avoids sample processing bias.. https://doi.org/10.1016/s0378-4347(99)00539-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

Highly selective and efficient determination of US Environmental Protection Agency priority phenols employing solid-phase extraction and non-aqueous capillary electrophoresis.

Non-aqueous capillary electrophoresis has been used in the separation of a complete list of 26 priority phenols included in the 8041 US Environmental Protection Agency method and the 76/464/EEC European Union directive. A highly selective and efficient separation was obtained when the background electrolyte used was 150 mM ammonium acetate dissolved in N-methylformamide-acetonitrile (75:25). Solid-phase extraction was successfully assayed as an enrichment strategy for the analysis of low-concentration samples. A styrene-divinylbenzene functionalized cartridge provided excellent recoveries of phenols from water samples at neutral pH. The limits of quantification obtained permit the application of the proposed method to the determination of priority phenols in wastewater samples.

Electrophoresis, Capillary↗

Capillary electrophoresis analysis of gentamicin sulphate with UV detection after pre-capillary derivatization with 1,2-phthalic dicarboxaldehyde and mercaptoacetic acid.

A selective, sensitive, and rapid pre-capillary derivatization method for determination of the multicomponent aminoglycoside antibiotic gentamicin is described. The derivatization reagents 1,2-phthalic dicarboxaldehyde and mercaptoacetic acid were used and the thioisoindole derivative was UV detected at 330 nm. A central composite experimental design was performed to optimize selectivity and derivatization conditions. Baseline separation of gentamicin C1, C1a, C2, C2a, C2b, sisomicin and several minor components was achieved with a background electrolyte containing 30 mM sodium tetraborate, 7.5 mM beta-cyclodextrin and 12.5% (v/v) methanol at pH 10. Quantitative analysis was performed and illustrated the potential use of capillary electrophoresis for the identification and quantitation of gentamicin as an alternative to methods prescribed in the United States Pharmacopeia and European Pharmacopoeia.

Electrophoresis, Capillary↗